Loading...
HomeMy WebLinkAboutProduct Approval -1z 0 RECEI D JUL 2.12015 MIAM!'1 DE 0112 MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) %,vnv.miamidadaQov/vera Union Corrugating Company P.O.Box 229 Fayetteville,NC 28302 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (hi Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 5V Metal Roof Panel LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-0214.15 and consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.:12-1231.03 MIAMMADECODUNTY Expiration Date:05/17/17 Approval Date:03/21/13 Page 1 of 11 ROOFING ASSEMBLY APPROVAL: Catenorv: Roofing Sub-Cateswry: Non-Structural Metal Roofing Material: Steel Deck Type: Wood Maximum Desmon Pressure -150 psf(See General Limitation#2) TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specifications Description 5V Metal Roof Panel Length:varies TAS 125 Metal Roof panel coated with various Width:26" approved coatings of Ceram-A-Star®900. (Coverage width:24") Height: r/Z" Min. Thickness 0.019" Min.Yield Strength: 78ksi MANUFACTURING LOCATION: 1. Ocala.,FL. 2. Fayetteville,NC. EVIDENCE SUBMITTED: Test Agengy Test Identifier Test Name/Reyort Date PRI Construction UCC-005702-01 TAS 125 01/06/12 Materials Technologies PRI Construction UCC-007-02-01 TAS-100 01/06/12 Materials Technologies Farrabaugh Engineering T164-06 TAS-125 06/08/06 and Testing,Inc. Farrabaugh Engineering T164-06 TAS-125 10/15/07 and Testing,Inc.. Akzo Nobel Coatings,Inc. Lab Test Certification ASTM B-117 ASTM G-23 PRI Asphalt HTL-001-01-01 PA 100 02/18/02 Technologies,Inc. Hurricane Test 0293-0202-06 TAS 125 06/05/06 Laboratory,Inc. Hurricane Test 0293-0609-05 TAS 125 06/22/05 Laboratory,Inc. NOA No.: 12-1231.03 MIAM%DADE COUNTY Expiration Date:05/17/17 Approval Date:03/21/13 Page 2 of 11 APPROVED ASSEMBLIES: System A: "5V26 Ga.Metal Panel Deck Type: Wood,Non-insulated Deck Description: New Construction or Re-Roof 15/32" or greater plywood or wood plank. Slope Range: 2": 12"or greater Maximum Uplift See Table A Below.(See Limitation#2) Pressure: Deck Attachment: In accordance with applicable Building Code,but in no case shall it be less than 8d ring shank nails spaced 6" o.c around the perimeter and 6" o.c. in the field. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum Underlayment shall be a ASTM D 226 Type H installed with a minimum 4" side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin- caps and 11/a" annular ring-shank nails, spaced 6" o.c. at all laps and two staggered rows 12"o.c. in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Union Corrugating Company's current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Metal Panels and Install the "5V Steel Roofing Panel" and accessories in compliance with Union Accessories: Corrugating Company's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards .RAS 133. 5V Roofing Panels shall be fastened with a minimum.of 49 Hex Head Wood corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of/1G". Fasteners shall be place in accordance with fastener detail herein as follows: 1. All fasteners are to be located on top of the ribs as shown in Detail A herein. 2. All fasteners at center rib,underlap rib, and overlap rib shall be spaced at a maximum distance listed in Table A below parallel to the roof slope. See Detail A herein. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -85.825 psf -113.1 psf Maximum Fastener Sp acin 24"o.c. 12"o.c. 1.Extrapolation shall not be allowed NOA No.: 12-1231.03 QM[AM%M1.D�ADECOU=NTY Expiration Date:05/17/17 Approval Date:03/21/13 Page 3 of 11 System B: "5V'26 Ga.Metal Panel Deck Type: Wood,Non-insulated Deck Description: New Construction or Re-Roof 15/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift The maximum allowable design pressure for the 24"wide panel Pressure• shall be-120.9 psf.(See Limitation#2) Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than#8 x 2" wood screws spaced 6" o.c around the perimeter and 12" o.c. in the field.. In reroofing, where the deck is less than 19/32" thick{Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment; Minimum underlayment shall be a ASTM D 226 Type H installed with a niiiiiinurn 4" side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin- caps and 11/4" annular ring-shank nails,spaced 6"o.c. at all laps and two staggered rows 12"o.c.in the field of the roll. Valleys:' Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Union Corrugating Company's current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Metal Panels and Install the "5V Steel Roofing Panel" and accessories in compliance with Union Accessories: Corrugating Company's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 5V Roofing Panels shall be fastened with a minimum of#9 Hex Head Wood corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient length to penetrate through the sheathing a minimum.OV/16". Fasteners shall be place in accordance with fastener detail herein as follows: I Panel side ribs shall be fastened along side of the panel inside ribs,one fastener at the overlap and one fastener at the underlap. Center panel rib shall be fastened with one fastener at the overlap side of the panel. 2. All fasteners at center rib,underlap rib, and overlap rib shall be spaced at a maximum of 24 inches o.c.parallel to the roof slope. See Detail B herein. NOA No.: 12-1231.03 MMMADECOU Expiration Date:05/17/17 Approval Date:03/21/13 Page 4 of 11 System C: "W'26 Ga. Metal Panel Deck Type. Wood,Non-insulated Deck Description: New Construction or Re-Roof 15/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table C Below.(See Limitation 42) Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c around'the perimeter and 6" o.c. in the field. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be a ASTM D 226 Type 11 installed with a minimum 4" side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin- caps incaps and 1'/"annular ring-shank nails,spaced 6"o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Union Cott ugating Company's current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Metal Panels and Install the "5V Steel Roofing Panel" and accessories in compliance with Union Accessories: Corrugating Company's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 5V Roofing Panels shall be fastened with a minimum of#9 Hex Head Wood corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of 3/16". Fasteners shall be place in accordance with fastener detail herein as follows: 1. All fasteners are to be located on side of the ribs as shown in Detail C herein. 2. All fasteners alongside center rib,underlap rib,and overlap rib shall be spaced at a maximum distance listed in Table C below parallel to the roof slope. See Detail C herein. TABLE C MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -63.75 psf -106.5 psf Maximum Fastener Spacing 16"o.c. 16"o.c. Fastener Location See Detail C—Field Condition See Detail C—Perimeter and Corner Condition NOA No.: 12-1231.03 MIAMNL?AD; 511� Expiration Date:05/17/17 Approval Date:03/21/13 Page 5 of 11 System D: "5V'26 Ga. Metal Panel Deck Type: Wood,Non-insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table D Below.(See Limitation#2) Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6"o.c around the perimeter and 6" o.c.in the field. Underlayment: Minimum underlayment shall be a ASTM D 226 Type R installed with a minimum 4" side laps and 6"end laps. Underlayment shall be fastened with corrosion resistant tin- caps and 11/4"annular ring-shank nails,spaced 6"o.c.at all laps and two staggered rows 12"o.c.in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Union Corrugating Company's current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Metal Panels and Install the "5V Steel Roofing Panel" and accessories in compliance with Union Accessories: Corrugating Company's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 5V Roofing Panels shall be fastened with a minimum of#9 Hex Head Wood corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of 3/ Fasteners shall be place in accordance with fastener detail herein as follows: 1. All fasteners are to be located on side of the ribs as shown in Detail C herein. 2. All fasteners alongside center rib,underlap rib,and overlap rib shall be spaced at a maximum distance listed in Table D below parallel to the roof slope. See Detail C herein. TABLE D MAXINHTM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -63.75 psf -150 psf Maximum Fastener Spacing 16"o.c. 16"o.c. Fastener Location See Detail C—Field Condition See Detail C—Perimeter and Corner Condition NOA No.: 12-1231.03 M"MADECOUNTY � • Expiration Date:05/17/17 �I p Approval Date:03/21/13 Page 6 of 11 LtmirmioNs 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e.field,perimeters, and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and comers). 3. Panels may be rolls formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo,and the following statement: "Miami-Dade County Product Control Approved"or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model. -DADE COUNTY MM MI �= 5. All products fisted herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. DETAIL DRAWINGS 2dr Coverage 5V PANEL NOA No.: 12-1231.03 OMMIANIONAODMECIOUNWRI Expiration Date:05/17/17 Approval Date:03/21/13 Page 7 of 11 DETAIL A—SYSTEM A Minimum#9HHself tapping screws w/self sealing. 3," i-6 Minimum penetration through the deck See Table A ------------ >�------ Overlap 12.9' Overlap PANEL OVERLAP FASTENER wl WASHER SUBSTRATE PANEL UNDERLAP NOA No.: 12-1231.03 MLAMI-DADECO Expiration Date:05/17/17 Approval Date:03/21/13 Page 8 of 11 DETAIL B—SYSTEM B Minim n#9HHself tapping screws w1 self sealing � "Mininwm penetration through the deck ~\ 24"ar- A Ab ® Ab � B �-- Overlap 125' Overlap PANEL OVERLAP /-FASIENERw/)AASFER \.\\.\\ \ 1\\\\.1\\.\ tl.i\ SUBSTRATE PANEL UNDERLAP MIAMI•DADE COUNTY NOA No.:12-1231.03 Expiration Date:05/17/17 Approval Date:03/21/13 Page 9 of 11 DETAIL C—SYSTEM C FIELD CONDITION Mdnwm##teff tapping SCrOAS W Self Seung. —,*Tdnirner pens rMan through the idm* db See Table C \ Overlap 125, 11.5' Ovedap PANEL OVERLAP FASTENER W WASHER SUBSTRATE _l PANEL UNDERLAP NOA No.:12-1231.03 IAAMIDE C0UNTY Expiration Date:05/17/17 Approval Date:03/21/13 Page 10 of 11 DETAIL C (CONTEWED)—SYSTEM C PERIMETER AND CORNER CONDITION IV rdn=n#9HHsdf taWng screvis id sdf sealing. 3"Mrdn=n pMeb-MCIn `1-6 ftnugh the dock See Tale C Ovedap ovedap PANE OVERLAP FASTENER mi VV49HFR 4^41 SLEUMTE PANEI-UNEEFLAPV END OF THIS ACCEPTANCE NOA No.: 12-1231.03 MW41-DADE COUNTY F-9, Expiration Date:05/17/17 Approval Date:03121/13 Page 11 of 11