Loading...
HomeMy WebLinkAboutProduct Approval r . , Page 1 of 2 Florida Budding Code Online t 7 ". 7' acts Moen trig in User RegistratOn Mot 10" Submt Surcharge Stats A facts Puhiicahom k"C Slott flclr,Sire Map 1 Business Professional u54W pub Approval rea:public Use n a ;u t st>Application Dotdi FL tt FLY0674•R10 Application Type Revision FILE COPY Code Version i 2014 Application Status '�—,:, ApprovedU-7o �4 Comments �f Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owen scorning.cam Authorized Signature Greg Keeler grog.keelertilrowenscoming.com Technical Representative Mel Sancrant Address/Phone/Email Y Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant0owenscornig.com Quality Assurance Representative Address/Phone/Email Category Rtiafing } SubcategoryAsphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Ltcenst,^d Flor,da Professional Engineer Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Robert).M,Nieminen Evaluation Report Honda License PE-59166 Quality Assurance Entity ULC Quality Assurance Contract Expiration Bate 08/20/2017 Y,) Validated By 'JtRSii 9G.Krtezevich,PE Validation Checklist- Hardcopy Received Certificate of Independence EL10674 RIO COI 2015 11 CQ Iiia;IL1eti Ls�t Referenced Standard and Year(of Standard) &t-red-rd Ysac ASTM 03161 2009 ASTM D3462 2009 ASTM 07158 2008 Equivalence of Product Standards Certified By Sections from the Code tillps,/floridabutidtng.org(prfpr_app_dtl.aspx?param=wGEVXOwtDgIBNbEY5V%2boQT%2b6w7ahReglC£l8ucR6ixEAoiMeKNJKxMw%3d%3d July 1.2015 Pago 2 of 2 FiotIda(wilding Code Online Product Approval Method Method 1 option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 summary of Products FLP Model,Number or Name Description 10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter anti hip&ridoe ahini}leo Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ:No LLJjW_4 E31Sl...I.L..+1415 0N1_FUNIC LR Q? _A;VIJAL.T Approved for use outside HVHZ:Yes 5fAttz L _FL10�? R1S�Lzti.t Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE- 59166 Design Pressure:N/A Created by independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports F135oS74 R10 AE-2015_01-FINAL SHING t21#1 Created by Independent Third Party: Yes fn r"r�'--_l9dn..r�i.tb tlflnt�+.SNta1r_'esf � :a°4hnf�e�lti,�Vie: iKza trio state of Florida Kan AAM0 efrPlO r-COWirght;Ir10j3Lil l start,of 11-16,a..::Dnua.v cratrm= -ar...:�.na,r1 Sr.aRm„nr,t: (1y;jrns St.,t�r_int Unlet I looda saw,email addresses are Public records,it you db not want your e-mall address released sn respoilSt to a puttk "Grids r.= t t do n.t,t mad to this aotity.Instead,contact the office by phone or by traditional mail.if you trove any questrom.p4taso contact n56,481.t 19 tui su t I, e -+ 455.275{1),nohda statutes,effecine,ottober 1.?o12,kaosees tnensed under Chapter 945,I.s.must provrr3€the Department with an Cz,xa t add c ' +`x'+,,, tine.The email,provided may be used for official COMMutwoabon with the beensee.However ernad addrexsrs are p„bht record_if yOu do nit wss to nuroir t V+ -nal address,please provide the Department with aR email address whKh car,be toad r avmlable to the public.To dcterm,ne if yea are a l,cert4.r'sad+,v�hacte atix. ' � place click bar— Product Approval Accepts- ® r:.*a;o x s untt htips'fflondabuilding,org/pr/pr_a dttaspx?param=wGEVXQwtQgtSNbEY5V%2boQT%2b6wfiahReglCQ8ucR6ixEAoiMeKNJKXMW%:Sd%3t2 July 1.2015 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN STREET,UNIT It 13 OXFORD,CT 06478 PHONE:(203)262 9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-RS One Owens Corning Parkway FL10674-RIO Toledo.OH 43659 Date of Issuance:02/06/2012 Revision 5. 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P•F. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity(ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 3 through 6. Prepared by: �at,ar,• ,,� + f.y Robert J.M.Nieminen,RE. •�s = °:� tt,c rM�u�t�ir,rai of>txarrng w„a,���,:� t„ M,t v, v.,. 'r��>•r.t.t•` PE on CNfll/LOIS Thio Q4lCt.tilt t.yr at G t rr,ty �,+•.f fiurrrla Registration No.59166,Florida OCA ANE1983 arKv cent sgPwd,raMa rear k pd ti s vr•h ,,.,.,, i =ar P—kKt Approval Ad,--Tata,and w for Hamra a.e�T. CERTIFICATION OF INDEPENDENCE: 1 Trinity(ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2 Trinity I ERD is not owned,operated or Controlled by any company manufacturing or distributing products it evaluates. 3 Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4 Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERa ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing .n accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prooetty Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM 03462 2009 1507.2.7.1,8905.2 6 1 Wind Resistance ASTM D3161 2009 1507 2.7 1,11905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity t"MIM-10n 1110sisnsn Date UL LLC(l.ER9626) Physicals&Wind Resistance File R2453,Vol.3 0211512007 UL LLC(CFR9626) Physicals&Wind Resistance 20120516 82453 05/16/2012 UL t LC(7579628) Physical Properties 06CA20263 04/18/2006 Ut.LLC(TS79628) Wind Resistance IICA34308 02118/2012 Ut LLC(TST9628) Physicals&Wind Resistance 4786093137 02101/2014 UL LLC(TS19628) Wind Resistance 4786126532 02/1012014 UL LIC(TST9628) Physical Properties Classification letter 0211312014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Vanuus UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp 08/10/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic!and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.13 Devonshire"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration% TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection. TruDefinition'Oakridge,Oakridge'and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip&Ridge Shingles and Duraltidge— Hip&Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roil are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to Current Approved Roofing Materials Directory for fare ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.I to ASTM D3161,Class F and/or ASTM 47158,Class H.indicating the shingles are acceptable for us in all wind zones up to V„,i-154 mph(V,,,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1547.2.71 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to V,u,=150 mph(V,,,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Ce r#kote of Authorization 89503 FL10674-R10 Revision 5:04/22/2015 Page 2 of 6 TRINITY ERD 5.43 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. SAA Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Cade and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: r Berkshire'shingles require minimum five(5)nails per shingle. WeatherGuard'HP shingles require minimum six(6)nails per shingle. Devonshire'"shingles require minimum six(6)nails per shingle. Starter Strip Plus requires minimum five(5)nails per strip, Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2,4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing–Classic"&Supreme. Non" s r edr dMvaArea pe Normal Mansard or Area para MW Y Nflnd Ana" High tNlnd disvarr"s Y Ana pan via i"normal" Areas vianta"roof," Area pan viontoa normara" Areas vi ntos foortas IA) Ir Expo•ora a 61s'Exposure Sspealcmn Fapoaial" 6.2.6 Minimum Nailing–Berkshire": SMMn amP 6.OYd sfr} It firs do"4010 U tka d►-W dw �•– �r---►rs--R f+ • —► •p •; sr----►".--s• •r "»-.-..•..--r• 1J1 '%1L R R�.24yowt tar+tb�j anmant z wota da txM d.e.taifo Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS cent/note of Aut1w1ration"9303 Ft 10674-R10 Revision S:04/22/2015 Page 3 of 6 TRINITY ERD 6.2.7 Minimum Nailing-Devonshire': # � Nails Nat15 Ten 1"Spots of As hah Roof Ctmew 6.2.8 Minimum Nailing—Duration*,TruDefinition'Duration,Duration*Premium Cool&TruDefinition*Duration*Designer Color Collection: 4 Nei Pattam 6 Nod Eagvuna da 4 d tvoa Patton 6uwNad"ltstaningawawidth Eagaama 44, • �.,:, Atli da claws SumNri1' dodo os I �,,. r}5>•#•rs..r#n • f � W?�•^.Kit-T�t,•'N:^ T — rr —•s► rr• t 141- o Naffs 5+'Expasw y S+pure.q,dda axposttton �� 61,pWq.da aapotara>n �.Kt`Expuwm Neh fxr,:...n• 51vpnli7.daarpnsirion Claw$ 5�riu�.dteipov,vr. 6.2.9 Minimum Nailing-TruOefinition*Oakridge',Oakridge•: d Naft Pattern 6 Nail Pattern Ewpow can 4 cows Eswww can 6 clowps r t- t' � I's— r{ --►I Ma'-'— rr--a►I v --rl ff—• tr 5 6 9'ExpowreNab5 519 Expmw FxpOwsitada66/Jpdf Cym" Espottaiar666/0putp. SSWExpoww Cys 5619"Ezpoww ttt Eapovtrdn da 6 619p+f4 Etpoutbn da 6 Sir P.14 61.10 Minimum Nailing—WeatherGuard•HP: so Vbw �iraraiaitaai*ui6tr Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certlfkate ajAuthoAtation 84503 Ft10674-R30 Revision 5:04/22/2015 Page 4 of 6 TRINITY ERD 6.3 Hip&Ridge Shingles. 6.3.1 Installation of Berkshire.Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard+ HP Nip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle, installation of DuraRidge"Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturers published requirements,but not less than FBC 1507.2.6 or 11905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire"Hip&Ridge and High Ridge: F1p.,t _.... k'' ,.. F19.2 � rirwtgwar x•1Mtpn f IxPMwx+ wx1,±N,� . tri 7 .. tart+nwaecd j...i1t► j 1- Met# 1......... 4 tr 17 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em sbw, 2-MggWindPatwm (4 Nails rind Shingle nd Discard ExeZ•t �. cs *trip 12" 'Fastenino Vhe' 5"Exposure Distance 12" -- 6.3.5 Minimum Nailing—WeatherGuard•HP Hip and Ridge: ------ Fig.C Hip&Ridge Shingle Fastening Fig.A `�� roaebw Coombe 1••11• ... '-^ ►o• . ; o e•tt1 w1a r ! V Wowwr-h i I 1V ...._........_...--5 14 fX Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certykate ofAatbor4ation x'4503 FL1067"10 Revision S-04/22/2015 Page S of 6 TRINITY ERo 6.3.6 Minimum Nailing-Prolidge Hip&Ridge Shingles: P'nvailling Standar Wind Dinetion setantanp Ftieni aattant 9 Expw., r 21 • r f� -r 12, r n Ssaunt i FaaNa T'h' 7,f', B"Exposure Fasteners with Reef Cwnent ......__ 2 6.3./ Minimum Nailing-DuraRidge"Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. ha.nM�Ytbd W.tian Tap V_ f'-Owns•KinrlMAxN dr wMt Yw aw p"n D.•ndenl•1 rinb p•danrwr"• �1- YNW iyrerwr I �.♦ tub NM KM... • • 0w C—l"4unfl�t' s I I r Tei; 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBG Table 1507.2.7.1/R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 Cyt requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC-QUA9625;(414)248-6409;karen.huchmannOul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certifkate o/Authorization 09503 FL 10674-RIO Revision 5:04/22/201S Page 6 of 6