Loading...
HomeMy WebLinkAboutProduct Approval Sales Agreement FILE COPY PO#:6008422 "u"O'=i '.Job��me:T06M 370-5492 This agreement is between Distributor and Customer Jou Address: jSaIesOrder# 79811 RECER". JUL 24-2015 I Quote Date:07107/2015 Ship To Customer Ship Toff A00271 Account# EAST COAST LUMBER&SUPPLY CO BRIAN HELSETH 308 AVENUE A 003708-6 FORT PIERCE,FL 34950-4417 Phone# Fax#(772)461-5957 Phone# Fax# Line# Item Description rQuantity Line Pricing 0001(1.00) DH5560 VINYL DOUBLE HUNG 5560 Ordered: List Price Sell Price Ext Price 36.X49.625X.,24,1-3/8"Nail Fin,W,EQUAL,718 2.00 $814.60 $491.95 $983.90 LIG,CL,SB 70XL,NO GRID,SWEEP,l 816K,Duraseal,2 CMFRT LFT HNL ---------- Ceruncation Type:AAMAA440 Package Selection:NONE Frame Type:1.375FIN Vent Configuration:EQUAL Size Selection:COMMODITY i Size Code:24.0000 Size Ref-ACTUAL Actual Size:36 X 49 518 056 Rough Masonry:37 3/4 X 50 5/8 Wood Frame:36 114 X 49 7/8 Egress:313/4 X 15 15/16(3.521 SQFT) Frame Color.White Does unit need to meet Turtle Code:NO Glass Family:Laminated Insulating Glass:7/8"LIG(1/8 AN-7/16 AIR-5116 AN/AN j Interlayer Type:PVB090 Argon Gas:NONE Glass Color:CLEAR Low E:ENERGY SHIELD MAX Privacy Glass:NONE Glass Spacer Type:DS Grid Type:NO Grid Screen Type:1816 Charcoal Screen Config:FULL Vent Latch:N i Comfort Lift:Y Top Sash Comfort Lift:Y j PositiveDesignPressure:65.0000 NegativeDesignPressure:70.0000 PANumber.FL 7058 x ", EnergyStar. Ge 1.0000 1 CondensationResistan :53.0000 UF:0.3500 SolarHeatGainGoeff.-0.2000 VT:0.4500 Xi VTCOG:0.6300 Location: 0002(2.00) DH5560 VINYL DOUBLE HUNG 5560 i Ordered: List Price Sell Price Ext Price 36.X62.X,25,1-3/8-Nail Fin,W,EQUAL,718 LIG,CL,SB 1.00 $954.60 $576.49 $576.49 i70XL,NO GRID,SWEEP,1816K,Duraseal,2 CMFRT LIFT HNL Sales Order# 79811 Print Date 7/23/2015 Page 1 of 2 w Certification Type:AAMAA440 1 Package Selection:NONE I Frame Type:1.375FIN I Vent Configuration:EQUAL Size Selection:COMMODITY { Size Code:25.0000 Size Ref:ACTUAL j Actual Size:36 X 62 1 I Rough Masonry:37 3/4 X 63 Wood Frame:36 1/4 X 62 1/4 { Egress:313/4 X 22 1/8(4.885 SQFT) Frame Color.White { I Does unit need to meet Turtle Code:NO I Glass Family:Laminated Insulating I j Glass:7/8"LIG(1/8 AN-7/16 AIR-5/16 AN/AN { Interlayer Type:PVB090 1 Argon Gas:NONE Glass Color:CLEAR 1 Low E:ENERGY SHIELD MAX ! Privacy Glass:NONE { Glass Spacer Type:DS { Grid Type:NO Grid Screen Type:1816 Charcoal j Screen Config:FULL Vent Latch:N I Comfort Lift Y Top Sash Comfort Lift:Y i PositiveDesignPressure:65.0000 NegativeDesignPressure:70.0000 PANumber.FL 7058 j EnergyStar.1.0000 CondensationResistance:53.0000 j UF:0.3500 f SolarHeatGainCoeff:0.2000 { t VT:0.4500 VTCOG:0.6300 Location: 1 i 0003 3.00 SH5500 VINYL SINGLE HUNG 5500 Ordered: List Price Sell Price --� Fact Price J 1 34.625X23.75X.,STD,1-3/8"Nail Fin,W,EQUAL,7/8 11.00 f $553.90 i $302.13 { $302.13 LIG CL SB 70XL,OB,NO GRID,SWEEP,1816K,Duraseal,CMFRT LFT HNDL j { Certification Type:AAMAA440 Package Selection-NONE - - Frame Type:1.375FIN Vent Configuration:EQUAL { 1 Window Style:STD i Size Selection:CUSTOM { Size Ref:ACTUAL Width:34 5/8 ® Height:23 3/4 Actual Size:34 5/8 X 23 314 Rough Masonry:36 3/8 X 24 3/4 j Wood Frame:34 7/8 X 24 Egress:30 3/8 X 7 3/16(1.523 SQFT) ; Frame Color White Does unit need to meet Turtle Code:NO j Glass Family:Laminated Insulating f Glass:7/8"LIG(1/8 AN-7/16 AIR-5/16 AN/AN Interlayer Type:PVB090 e Argon Gas:NONE Glass Color.CLEAR y Low E:ENERGY SHIELD MAX Privacy Glass:OBSCURE ` I Privacy Glass Location:UNIT I Glass Spacer Type:DS Grid Type:NO Grid I Screen Type:1816 Charcoal Vent Latch:N I Comfort Lift:Y f PositiveDesignPressure:65.0000 NegativeDesignPressure:70.0000 PANumber.FL 1435 EnergyStar.1.0000 CondensationResistance:53.0000 XUR 0.3300 SolarHeatGainCoeff.-0.2200 { VT:0.4800 VTCOG:0.6300 �Location: `` I 1TOTAL AMT: j $1,862.52+ TOTAL TAX: $121.06 *ET AMOUNT: $1,983.58 I-- Sales Order# 79811 Print Date 7/23/2015 Page 2 of 2 RECEIVED JUL 24.2015 DocunentTltle: Doc No: FRM B1-43 ��- Impact Performance Rey No: 4 pagm 1 O1: 1 KSYSTON Certification Authorization Report Requred By: PRO 61-03 FILE O Pv CAR& Product ID Number: 190 - 286 Issue Date: 11/17/2014 Revision Date: 11/17/2014 Expiration Date: 10/6/2018 Company Code: 190 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc.(KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products,that inose products are representative of the specimen evaluated and documented for cert cation authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts com. Licensee Information: Product Information: PGT Industries del: SH5500 View PVC Imp Single Hun 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: EM/All, GS-5/16"Ann Lami IG Max Width: 52 Max Height: 92 Corresponding Structural CARs: 190-1029.0 Referenced Standard: Product Rating: ASTM E1886-05/E1996-12 Missile Level D,Wind Zone 4, DP=+65/-70, 52x92 Qualifying Test Information: Test Report No: FTL-7954/7955/7956 Test Report Expiration: 10/6/2018 Authorized Signature: Keystone Certifications, Inc. Digitally signed by Steven M.Urich 564 Old York Road, Suite 5 97 ON:cn=Steven M.Urlch,o=Keystone Certifications,Inc.,ou, Etters, Pennsylvania 17319 email=surich@keystonecerts.com,c=US Phone:717-932-8500 Date:2014.11.17 15:5023-05'00' Fax: 717-932-8501 W W W.KEYSTONECER-rS.COM DocuneMTut:: Doc No: FRIVI B1-02 Structural Performance Rev No ' Pew ' ' KgYSToNg C�..,..a,., . . Certification Authorization Report Required By: PRO B1-03 CAR& Product ID Number: 190 1029.0 Issue Date: 11/11/2014 Revision Date:. 11/17/2014 Expiration Date: 10/1/2018 Company Code: 190 This Certification Authorization Report(CAR)is issued by Keystone Certifications, Inc.(KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specked referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products,that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verged atwww.keystanecerts com. Licensee Information: Product Information: PGT Industries Model,SH5500 View PVC Imp Single Hung 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: EM/AII, GS-5/1W Ann Lami IG Max Width: 52 Max Height: 92 Referenced Standard: Product Rating: AAMAANDMA/CSA 101/I.8.2/A440-11 Class LC-PG651324x2330(52x92)-Type H Neg DP=70 5 Qualifying Test Information: Test Report No: FTL-7950 Test Report Expiration: 10/1/2018 Authorized Signature: _ Digitally signed by Steven M.Unch Keystone Certifications, Inc. Div:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 Certifications,Inc,ou, Etters, Pennsylvania 17319 .2/ email=surich@lceystonecerts.com, Phone: 717-932-8500 c=US Date.2014.11.17 15:55.47-0S'00' Fax: 717-932-8501 f. W W W.KEYSTONECERTS.COM I EDGE DISTANCE SHOWN INSTALLED 'SHOWN INSTALLED THROUGH THE SHOWN INSTALLED THROUGH THE THROUGH THE ± FRAME INTEGRAL FIN FRAME -^—+^f-- EMBEDMENT EDGE DISTANCE --•�-� I�--- J-CHANNEL EMBEDMENT FRAME _ /} SHOWN �oEMBEDMENT o / EDGE — J DISTANCE l6 �1 OPT.SASH TOP ^^— EXTERIOR LIFT RAIL FIN FRAME J-CHANNEL SHOWN O - FRAME BUCK WIDTH -- '--+- SHOWN 0 HORIZONTAL SECTION C-C INSTALLATION NOTES: BUCK HEIGHT a ,0 1)SEE SHEET 1 FOR SPACING REQUIREMENTS, 2)SEE TABLE(S)ON SHEET 2 FOR I ANCHORAGE AND SUBSTRATE f REQUIREMENTS, i 3)MAX,SHIM THICKNESS TO BE 1!4". �I�R 4)GLASS SHOWN IS FOR ILLUSTRATIVE ` I ' PURPOSES ONLY AND MAY DIFFER TO I MEET DESIGN REQUIREMENTS. , t r b)FIN ANDIOR FLANGE MAY BE REMOVED i I TO CREATE OTHER FRAME TYPES. .i I OPT.SASH ' I BOTTOM LIFT FIN FRAME �HANDLEA.00K SHOWN EXTERIOR FIN _ EXTERIOR FIN FRAME o FRAME c•� } SHOWN SHOWN , INSTALLATION THROUGH INSTALLATION THROUGH THE THE FRAME,INTO METAL INTEGRAL FIN,INTO METAL `off LYNN........lieSHOWN EDGE INSTALLED DISTANCE _ �1��.•'��CEtJSg '•.'P* THROUGH ;> VINYL S FPA IMP:RES 12/13/14 Fg'705 THE EDGE ( 8 INTEGRAL FIN _ WTE DISTANCEJ-CHA � L&INTEGRAL FIN FRAMES 6`DROSOWSKIEMBEDMENT _ �w� VERTICAL SECTION D-d I CERT.OFAUTH.112B216 �° 0c�'•.F�OR�°P'�C��;� VERT-- 1070 TECHNOLOGY DRIVE 'g N.VENICE,FL 34275 d - x (941) IL -480-1600 SH-5500 NTS 4 OF 4 s z FPA-5500,0 rc z A.LYNN A 588TO15'RE, I i ,,,,,,,,,��� i EDGE DISTANCE SHOWN � qo, INSTALLED THROUGH 1X BUCKSTRIP EMBEDMENT FLANGE SHOWN SHOWN FRAME INSTALLED INSTALLED SHOWN DIRECTLY TO THROUGHIX EMBEDMENT- _ --- EMBEDMENT SUBSTRATEEDGE BUCKSTRIP _ �❑ EDGE DISTANCE DISTANCE `OPT,SASH TOP - __ w.nv.ivwwww..v. 1 / EDGE J LIFT RAIL EXTERIOR JI ��DISTANCE 0 FLANGE -� E I L p D SHOWN - -"—""— BUCK WIDTH FRAME HORIZONTAL SECTION A-A SHOWN BUCK HEIGHT o I [� INSTALLATION NOTES: 1)SEE SHEET 1 FOR SPACING REQUIREMENTS. EXTERIOR 2)SEE TABLE(S)ON SHEET 2 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS, 3)MAX.SHIM THICKNESS TO BE 114'. 4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ) ONLY AND MAY DIFFER TO MEET DESIGN OPT.SASH REOUIREMENTS. BOTTOM LIFT FRAME FLANGE 5)FIN AND/OR FLANGE MAY BE REMOVED TO CREATE j DHANDLE/LOCK SHOWN OTHER FRAME TYPES, 1 EQUAL 7�l LEG FRAMEBXTE� SHOWN I INSTALLATION THROUGH n I ` �Q THE FRAME,INTO METAL V ���� Y ILYNN 1U NO ANCHORS Q.r• I REQUIRED IN FLANGE OR VINYL SH WINDOW FPA(IMP.-RESIST.) 12/13/14 - No.58705 EQUAL-LEG FRAME SILLS F FLANGE&EQUAL-LEG/BOX FRAMES o,; J ROSOWSKI ® o � S E <C/. CERT.OF AUTH.#29288- 1xo 'O��C`•'••..... P,.•'G\?� VERTICAL SECTION B-B %SS'1 1070 TECHNOLOGY DRIVEgNAL- ` N.VENICE,FL 34275 u A.LYNN MILLER.PF, j (941}480-1600 a SH-5500 1 NTS 3 OF 4 �= FPA-5500.0 �z P.E.4 58705 i TABLE 2:ANCHORS INSTALLED THROUGH FRAME TABLE 3:ANCHORS INSTALLED THROUGH INTEGRAL FIN Anchor Substrate Min.Edge Min. Anchor Substrate Min.Edge Min. Distance Embedment Distance Embedment #10P.T.Southam—Pine(SG+ ,55) 7/1 1 2-1/2'x.131"Common Nadi P.T,Southern Pine(SG=.55) 9/16" 2-7118" (steel,18.8 S.S. Steel,A36 3/8" 0.050" Max.OP of 50.0 or 410 S.S.) Steel Stud,A653 Gr.33 3/8" 0.0346"(20 Ga.) 2-1/2"x.131"Ring-sharm Nail P.T.Southem Pine(SG=.55) 9116" 2-7/16" Max.�+0050 0 Aluminum,608315 3/8" 0.050 2-112"x.145"Roofing Nail P.T.Southam Pine(SG= 9116" 2-7118' P.T.9outhem Pine SG 0.55) 9/16" 1318 #12 SMS P.T.Southem Pine(SO=.55) 314• 1318° Sted,A36 3/8" 0.050" #10 SMS (steel,18 8 S.S. sled,18$S.S. Aluminum,6063-T5 318' 0.050" Steel Stud,A653 Gr.33 318" 0.0346" Ga.) or 41,0 S.S,) Aluminum,8083-T5 3/8" 0.063" or 410 S.S.) Steel Stud,Gr.33 3/8' 0.0346'(20 Ga.) 3118"Ultracon P.T.Southem Pine(SG�.65) 7/18" 1318" Steel,A38 3/8• 0.050' (steel) Concrete min.285 ksi) 1" 1.318" Max.OP 0050.0 Un routed CMU, STM CSO 2-1/2" 1.1/4" ANCHOR NOTES: P.T.Southern Pine(SG�,65) 1" 13+8" GE-7700 OR 1/4"Ultrecon Concrete(min.2.85 ksi 1" 1-3/4" 1)'UNGROUTED CMU'VALUES MAY DOW 701 (steel) Ungmuted CMU, STM C-90 2-1/2" 1.114" BE USED FOR GROUTED CMU SILICONE APPLICATIONS. Concrete min.2.85 ksi) 2-1/2" 1314" 1/2"NOM.GLASS P.T.Southam Pine SG=0,55) 1" 1-318" 2)PANHEAD,FLATHEAD OR t XTERIOBITE TYP• R 1!4"Crete-Flox Concrete(min.3.35 ksi) 1" 1.314" HEXHEAD ARE ACCEPTABLE, h, (410 S.S.) Un uted CMU,(ASTM CSO 2-V2" 1-114" 3)ANCHOR LENGTH TO BE SO THAT fir-' Concrete min.3.36 ksi 2-1/2" 1.9/4" A MIN.OF 3 THREADS EXTEND Concrete(min.3.275 ksl 1-112" 13/8" BEYOND THE METAL SUBSTRATE. i/4°Aggre•Gotor P.T.Southam Pine(SG=0.65) 1" 146" TYP.GLAZING DETAIL (18 8 S.S.) UrigMuted CMU ASTM C-90 2' 1-1/4" i REINFORCENT TYPE A n i WINDOW SHAPES AS SHOWN BELOW OR 716'NOM. �-• -+{ 718'NOM. SIMILAR,MAY BE USED BY IN5CRISING THE SHAPE IN A BLOCK AND OBTAINING DESIGN _ PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE TABLE ON SHEET 1. 6/16"A/A PVB 5/16"AIA PVB REINFORCENT TYPE B —+{ WIDTH WIDTH 7116"AIR SPACE 3/8"AIR SPACE 1/8"ANNEALED OR 3/16"ANNEALED OR T TEMPERED GLASS TEMPERED GLASS T DURASEAL, DURASEAL, 10 _ SUPERSPACER_. _ SUPERSPACER REINFORCENT TYPE C OR CARDINAL OR CARDINAL I XL EDGE XL EDGE RADNSrOP -ARcrnaa GLAZING TYPES I (EOVN.U7E 6MOW4) (PROVIEWIORIEL SHOW.) \� NY LYNN 4fi TABLE 4:REINFORCEMENT TYPES PVB INTERLAYER MANUFACTURED BY DUPONT INC.(AKA KURARAY AMERICA,INC.) ` �O'��CENSF'•<<F,p' Reirdamem®nt zk:' U erLite Lower lite � VINYL SH WINDOW FPA(IMP:RESIST.) 4 12/13/14 _ No,56705 Level Bottom Bottom Side GLASS/ANCHOR OPTIONS ;mom J ROSOWSKI =-0 rtau Top Ran Reu Rens =�' ` I �S:�� I ® ; ST TE R1 B A A A CERT.OF AUTH.#29296 ¢ �� %�(�`s''•c<OR10 P.•''G\?� R2 C A A A 1070 TECHNOLOGY DRIVE t M ':,'ZONAL N.VENICE,FL 34275 (941)480-1600 SH-5500 NTS 2 OF 4 o z FPA-5500.0 € A.LYNN.#18NE05,P.E. i MAX,SUCK WIDTH SEE TABLE I MAX SUCK WIDTH 26* MAX.SUCK WIDTH SEE TABLE 1 MAX. SEE TABLE I 28' ir O.C. 2'MAX MAXI [-*-- B.SEE MAX. 0,SEE 4"MAX.D.C. MAX, D.C. 3 B.SEE 12 SHEET SHEET4 SHEET A.SEE 12"MAX C,SEE A.SEE 12 MAX. SHEET 3� SHEET 4 SHEET 3 1 + ii 1 17.867"MAX,O.C. 17,867'MAX.O.C. MABUCK 0 MAX BUCK 4'MAX. I 0HEIGHT SEE HEIGHT SEE 04 TABLE I TABLE I i i H TABLE E x IT MAX D.C. X 0' 7// 13.773' -—-—- 10'MAX.Op. C MAX.AX O,C. T IA A 13.773"MAX,OC. . I _s7ire MAX 8-1/r MAX. 2*MAX. I- NO ANCHORS AT ELEVATION FOR TYP.FIN OR J-CHANNEL FRAME, ELEVATION FOR TYP.FLANGE FRAME., EQUAL-LITE_CONFIGURATION ELEVATION FOR TYP.EQUAL LEG FRAME, CONFIGURATIONS CONFIGURATION PROVIEW/ORIEL CONFIGURATION (SIMILAR ANCHOR DIMENSIONS FOR OTHER C, EQUAL-LITE_C (pp)[T&qS SIMILUR GENgM4 tj0 YIN j9q:A9,fj!9S_AL0QA_PACT RESISTANT,,VINYL SINGLE HUNG WINDOW I)THIS PRODUCT HAS BEEN DESIG14FO&TESTED To COMPLY WITH THE TABLE 1: fi REQUIREMENTS OF THE FLORIDA BUILDING CODE. Window Suck Size Relaf. Design Pressure Certification SHAPES MAY BE USED By444 2)ALL WOOD BUCKS LESS THAN I.1rr THICK ARE TO BE CONSIDERED IX Configumflon - (j psf (CAR)Number INSCRIBING THE SHAPE IN —I Heigh Level A BLOCK AND OBTAINING INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY —Qldth It R)P8f — DESIGN PRESSURES FOR To SUBSTRATE,WOOD BUCKS DEPICTED AS 2X ARE 14re THICK OR GREATER. 52.1/6r 8=4 Equal-lite THAT BLOCK SIZE FROM ix AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS To THE STRUCTURE.WOOD SUCK DESIGN AND INSTALLATION Is THE 52-1/W W Sid.ProView R1 50.0 50.0 1�285,1MB THE TABLE ON THIS SHEET. RESPONSIBILITY OF THE ENGINEER,(EOR)OR ARCHITECT OF RECORD,(ACR). 52-1/8" 91-13116P Custom Sash 3)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.USE ANCHORS OF SUFFICIENT EMBEDMENT.INSTALLATION 52-1/8' W Equal-file ANCHORS SHOULD BE SEALED,OVERALL SEALINCIfFLASHN0 G STRATEGY FOR 52-184' Std. R2 70.0 190-286,1029 WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS Q:.O: I BEYOND THE SCOPE OF THESE INSTRUCTIONS. 52-1/8"_ gi-lativi Custom Sash OW,11111" V LYNN 4,1� 4)MAX.114-SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE 0. .......... PRODUCT IS NOT FLUSH TO THE SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS,WOOD BUCKS,BY OTHERS.MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. No.53705 a VINYL SH WINDOW FPA(IMP.-RESIST.) 12113114 6)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE ' 14 WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE GENERAL NOTES ELEVATION S J ROSOWS19 33-113Y STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS 5 0 10. ST1,TE TE F PRODUCT.THE 1.8 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO CONTACTWITH OTHER b's (:3Z "p ........... DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA CERT.OF AUTH.W9290 '1,,&/0NP_ BUILDING CODE FOR CORROSION RESISTANCE. 1070 TECHNOLOGY DRIVE "III 11101, N.VENICE,FL 34275 A.LYNN MILLER,P.E. PEO SW-5500 91 NT 58705 (94IY48D-1600 RECEIVED JUL 24'2015 DocunentTitle: Doc No: FRM 81.43 —�M Impact Performance ReV No: 4 Pa W- ' °` ' KEYSTONE Certification Authorization Report R++aL11recl By= PROBI-03 CAR& Product ID Number: 190 - 287 ���m Issue Date: 12/23/2014 COPY Revision Date: 12/23/2014 Expiration Date: 11/19/2018 Company Code: 190 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: PGT Industries < Model: DH5560 PVC Impact Fin/Equal Leg Double Hung 1070 Technology Dr. PO Box 1529 Ope Nokomis FL 34274 Config: All, GS-5/16"Ann Lami IG Max Width: 52 Max Height; 86 Corresponding Structural CARs: 190-1034.0 Referenced Standard: Product Rating: ASTM E1886-05/E1996-12' Missile Level D,Wind Zone 4, DP=+/-50, 52x86 Qualifying Test Information: = Test Report No: FTL-7981/7982 Test Report Expiration: 11/19/2018 Authorized Signature: Keystone Certifications, Inc. Digitally signed by Steven rut.Urich 564 Old York Road,Suite 5 DN:cn=StevenM Urlch,o=Keystone . Etters, Pennsylvania 17319 �1 Certifications,Inc,o% emall=surich@keystonecerts.com,c=US Phone: 717-932-8500 Date:2014.12.30 073437-0500' Fax: 717-932-8501 i W W W.KEYSTO NECERTS.COM DocunentTift Doc No- FRM 81-43 Impact Performance Rev No. 4 pagm 1 1 KEYSTONE Certification Authorization Report ReQuired_By: PRO B1-03 CAR&Product ID Number: 190 - 288 Issue Date: 12/23/2014 Revision Date: 12/23/2014 Expiration Date: 11/19/2018 Company Code: 190 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates In affixing certification labels to products, that Mose products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: PGT Industries Model: DH5560 PVC Impact Fin/Equal Leg Double Hung 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: All, GS-5/16"Ann Lami IG Max Width: 52 Max Height: 86 Corresponding Structural CARS: 190-1035.0 i Referenced Standard: Product Rating: ASTM E1886-05/E1996-12 Missile Level D,Wind Zone 4, DP=+65/-70, 52x86 Qualifying Test Information: s Test Report No: FTL-7983/7984 Test Report Expiration: 11/19/2018 Authorized Signature:- Keystone Certifications, Inc. 3 Digitally signed by Steven M.Urich 564 Old York Road, Suite 5 DN_caenM Urich,o=Keystone Ettets, Pennsylvania 17319 =d !.1✓�/ Certifications,Inc.,ou, email=surich@keystonecerts.com,r—US Phone: 717-932-8500 Date 2014.12-30 08:03-01 OS'rm' Fax: 717-932-8501 W W W.KEYSTONECERTS.COM Docunent Title: Doc No: , FRM 81-02 Structural Performance Rev No: , w 1 1 KEYSTONE' Certification �itilTIIIC.ATONr.IMC. - L.� Authorization Report Required.By: PRO.81-03 CAR& Product ID Number: 190 - 1034.0 Issue Date: 12/23/2014 Revision Date: 12/23/2014 Expiration Date: 11/19/2018 Company Code: 190 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc.(KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products,that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in anis report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: PGT Industries Model: DH5560 PVC Impact Equal Leg Double Hung 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: All, G.S-5/16"Ann Lami IG Max Width: 52 Max Height: 86 Referenced Standard: Product Rating: AAMA/WDMA/CSA 101/i.S.2/A440-11 Class LC-PG50 1324x2192(52x86)-Type H WTP=9.75 Qualifying Test Information: Test Report No: FTL-7979 Test Report Expiration: 11/19/2018 Authorized Signature: Digitally signed by Steven M.Urich Keystone Certifications, Inc. DN:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 �) Certifications,inc.,ou, Etters, Pennsylvania 17319 email=surich@keystonecerts.com, c=US Phone:717-932-8500 Date:2014.12.30 0753:49-05'00' Fax: 717-932-8501 wW W.KEYSTONECERTS.COM DocunentTitb: DOC NX FRIVI81-02 Structural Performance Rev No: 7 Pagm 1 Of, 1 KF-YSTON Certification Authorization Report Re9tured.13Y: PRO 81-03 CAR& Product ID Number: 190 - 1035.0 Issue Date: 12/23/2014 Revision Date: 1.2/231201.4 Expiration Date: 11/19/2018 Company Code: 190 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: PGT Industries Model: DH5560 PVC Impact Equal Leg Double Hung 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: All, GS-5/1.6"Ann Lami IG. Max Width: 52 Max Height: 86 Referenced Standard: Product Rating: AAMANVDMA/CSA 101/l.S.2/A440-11 Class LC-PG651324x2192(52x86)-Type H Neg DP--70 Qualifying Test Information: Test Report No: FTL-7980 Test Report Expiration: 11/19/2018 Authorized Signature: Digitally signed by Steven M.Urich Keystone Certifications, Inc. DN:cn=Steven M.Urich, 564 Old York Road, Suite 5 o=Keystone Certifications,Inc.,ou, Etters, Pennsylvania 17319 emall=surich@keystonecerts.com, c=US Phone: 717-932-8500 Date:2014.12.30 08:02:31-05'00' Fax: 717-932-8501 t WWW.KEYSTONECERTS.COM MAX.BUCK WIDTH MAX.BUCK WIDTH SEE TABLE SEE TABLE 1 28 1 M28'AX. �+— 1Y �-- O.C. IM MAX.BUCK WIDTH 8,SEE SEE TABLE 1 12' O.C. � 2'MAX. ? B,SEE MAX. SHEET 3 B.SEE —�) �+— 4'MAX.O.C. � SHEET 9 _ �� ' SHEET 3 12'MAX. SHEET 4 i A.SEE I 12'MAX. 1 ._L•_ A.SEE SHEET31 SHEET 4 ? EQUALLY 13.15/16'MAX.O.C. ANSPACEDCHORS ` J/ �L EQUALED I I 13.16 16'MAX.O.C. x J'T_ ANCHORS x MAX.BUCK I V MAX.BU K .T_ MAX,BUCK HEIGHT S E HEIGHT SEE t1 x A 10'MAX.O.C. HEIGHT TABLE 1� X TABLE 1 x 4 TABLE 1 lJ EQUALLY I `." 16'MAX.O.C. — 10'MAX.O,C.yI I /^ SPACED �— x Q —13.1 ANCHORS p� EQUALLY / A 13.73/16'MAX.O.C. 4'MAX. A SPACED O.C. ANCHORS •_�+}-_. �T B•11z'MAX / &1l2'SUX. {{I B-t NO ANCHORS AT SILL - B y_ry0 ANCHORS AT SILL g 2'MAX. ELEVATION FOR TYP.EQUAL LEG FRAME, ELEVATION FOR TYP.FLANGE FRAME, ELEVATION FOR TYP,FIN OR J-CHANNEL FRAME, I EQUAL-LITE CONFIGURATION PROVIEW/ORIEL CONFIGURATION EQUAL-LITE CONFIGURATION {SIMILAR ANCHOR DIMENSIONS FOR OTHER CONFIGURATIONS) GENERAL NOTES:SERIES 5560 IMPACT RESISTANT,VINYL DOUBLE HUNG WINDOW. TABLE 1: 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE Window Buck Size Reinf, Design Pressure Certification REQUIREMENTS OF THE FLORIDA BUILDING CODE. Width Height Configuration Level (i)PB{ (.)Psp (CAR)Number 2)ALL WOOD BUCKS LESS THAN 1-12'THICK ARE TO BE CONSIDERED 1X 52-118" 84' Equal-lite INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY ' TO SUBSTRATE,WOOD BUCKS DEPICTED AS 2X ARE 1-12'THICK OR GREATER. 52-118" 75' Std.ProView R1 50.0 50.0 190-287,1034 I IX AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER 62-1/8" 86-3/8" Custom Sash k LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND INSTALLATION IS THE !' RESPONSIBILITY OF THE ENGINEER,(EOR)OR ARCHITECT OF RECORD,(AOR). 624/8" 84" Equal-lite 3)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING 52-118" 75" Std.ProView, R2 65.0 70.0 ` 90-288,1035 OR STUCCO,USE ANCHORS OF SUFFICIENT EMBEDMENT.INSTALLATION $2-118" 86-3/8" Custom Sash ANCHORS SHOULD BE SEALED.OVERALL SEALING(FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS j BEYOND THE SCOPE OF THESE INSTRUCTIONS. 4)MAX.1/4'SHIMS ARE REQUIRED A7 EACH ANCHOR LOCATION WHERE THE p'• •• ^%T, PRODUCT IS NOT FLUSH TO THE SUBSTRATE,USE SHIMS CAPABLE OF ��` •''��!:�5.` FP ' TRANSFERRING APPLIED LOADS.WOOD BUCKS,BY OTHERS,MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 5)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE VINYL DH WINDOW FPA(IMP.-RESIST.) 8 12/13/14 WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE I 33.1!3°h STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS 9 GENERAL NOTES&ELEVATIONS 1, J ROSOWSKI '-''� "" PRODUCT,THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF o " /(.7{.', ANCHORS INTO WOOD.ANCHORS THAT COME INTO CONTACT WITH OTHER ® > :'.'•• LGRlO:••',�':- DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA CERT.OF AUTH.#29296 BUILDING CODE FOR CORROSION RESISTANCE. 1070 TECHNOLOGY DRIVE L 0: N.VENICE,FL 34275 (941)-480-1600 DH 5560 NTS 1 OF 4 o x° FPA-5560.0 x z° LYp E.0 58705 P E i TABLE 2:ANCHORS INSTALLED THROUGH FRAME TABLE 3:ANCHORS INSTALLED THROUGH INTEGRAL FIN Min.edge Min. Min,Edge Min. j Anchor Substrate Distance Embedment Anchor Substrate Dldance Embedment 0 3 . .Southern e 1 2-1/2'x.131"Common Nall (steel,18$S.S. Steel,A36 318" 0.050" Max.DP of 60.0 P.T.Southern Pine(SG=.65) 8118' 2-7l10° or 410 S.S.) Steel Stud,A663 Gr.33 3/8" 0.0348" 20 Ga.) 2-112•x.131"Ring-ehank Nell P.T.Southern Pine(SG=.56) 8/18' 2-7/161 Max.OP ot50.0 Aluminum,E063-T5 3/8" 0.0713" 14 Ga. 2-112°x.145'Rooting Nall P.T.Southern Pine(SG=.55) 8118• 2-7/16' -0b[ 012 SMS P.T.Southern Pine(SG-0.55) 0/18" 1.3+8" P.T,Southern Pine(SG=.65) 314" 1.318• Steel,A38 3/B' 0.050' #10 SMS Aluminum,8083-T5 3/8' 0.0713. 14 Ga,) (steel,18.8 S.S. ( s Steel Stud,A663 Gr,33 3/8' 0.0348'(20 Go.) (steel,I"S.S. ! or 410 S,S.) Aluminum 8083 T5 318° 0.0713" 14 Ga. or 410 S.S.) stool Stud,Gr.33 are° o.o34e•(20 Ga.) 3116" Itmcon P.T.Southern Pine(S' 55) 7/18" 13'8" steel,A36 3/8• 0.050" (steel) Concrete min.2,85 ksq 1" 13/8" Max.OP of 50.0 Un routed CMU, STM C 90 2-112° 1-114" 0 i P.T.Southem Pile SG-0.55) V 1-W 114"Ulhacon Concrete(min.285 ka( 1" 131d" 1)-UNGROUTED CMU"VALUES MAY i (steel) Unpmuled CMU,(ASTM C-00 2-112" 1.1/4` BE USED FOR GROUTED CMU APPLICATIONS. I Concrete in.2.85 ksl 2-112" 1314" P.T.Southern Pine G=0.5 1" 1318 2)PANHEAD,FLATHEAD OR GE-7700 OR MEXHEAD ARE ACCEPTABLE. DOW781 114"Crete•Flex Concrete(min.3.36 ksl) 1" I_ve SILICONE (410 S.S.) Ungrouted CMU, ASTM C-90) 2-112" 1-114" 3)ANCHOR LENGTH TO BE SO THAT iPl rJOM.GLASS A MIN.OF 3 THREADS EXTEND Concrete min.3.35 ks( 2-112" 1314" BITE TYP. BEYOND THE METAL SUBSTRATE. 1/4"Aggre•Gator Concrete min,3.276 kel) 1-112" '1318" BEYOND 1 P.T.Southam Pine(SG-0.5WM I1. 1.316" ! (1&8 S.S.) Un ted CMU STM C•90 2' 1-1l4" i TYP.GLAZING DETAIL i 718'NOM. �+--- � 718'NOM. ) 5/16'AIA PVB 5/16"A/A PVB 7/16"AIR SPACE 3/8"AIR SPACE 116"ANNEALED OR 3/1 B"ANNEALED OR TEMPERED GLASS TEMPERED GLASS DURASEAL, I10 DURASEAL, REINFORCENT TYPE A REINFORCENT TYPE B REINFORCENT TYPE C SUPERSPACER_ SUPERSPACER i OR CARDINAL OR CARDINAL XL EDGE XL EDGE GLAZING TYPES f t TABLE 4:REINFORCEMENT TYPES PVB INTERLAYER MANUFACTURED BY DUPONT INC.(AKA KURARAY AMERICA,INC.) �c ' Reinforcement ;:`•' ;Ir,. ';a5 VINYL DH WINDOW FPA(IMP.-RESIST.) 8 12/13/14 _ '• - upperuteI Lower lite Leve! Top Bottom Top Bottom SldeGLASS/ANCHOR OPTIONS s J ROSOWSKI Rall Rall Rall Rail Rails b ;d •�c•,;• .,.�Lr,��`?°>',1t�' RI A B B A A CERT.OF AUTH.#20288 N N R2 A C C A A 1070 TECHNOLOGY DRIVE N.VENICE,FL 34275 v A.LYNN MILLER,P.E. (941)-480-1600 y DH-5580 �°, NTS � 2 OF 4 s z FPA-5560.0 a� P.E.ri 58705 I EDGE DISTANCE SHOWN INSTALLED THROUGHIX EMBEDMENT BUCKSTRIP SHOWN SHOWN FLANGE INSTALLED INSTALLED FRAME DIRECTLY TO THROUGH ix EMBEDMENT SHOWN E EMBEDMENT SUBSTRATE BUCKSTRIP � 1114 EDGE EDGE DISTANCE DISTANCE BOTTOM SASH EDGE TOP DISTANCE SASH EXTERIOR T OPT.SASH TOP LIFT RAIL FLANGE EQUAL FRAME SHOWN y FRAME BUCKWIDTH -----'----JSHOWN HORIZONTAL SECTION A-A SUCK > HEIGHT` 1)SEE SHEET I FOR SPACING REQUIREMENTS. 2)SEE TABLE(S)ON SHEET 2 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. FLANGE 3)MAX.SHIM THICKNESS TO BE FRAME 4)GLASS SHOWN is FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REOU REMENT& 1 OPT.SASH 6)FIN ANDIOR FLANGE MAY BE REMOVED TO CREATE 1 BOTTOM LIFT OTHER FRAME TYPES. .HANDLE INSTALLATION THROUGH EXTERIOR THE FRAME.INTO METAL o' R NO ANCHORS -2 VINYL DH WINDOW FPA(IMP: ESIST.) b 12!13114 EQUAL REQUIRED IN LEG FLANGE OR T FLANGE EQUAL-LEG/SOX FRAMES X��j J ROSOWSKI EQUAL AIV FRAME -LEG SHOWN FRAME SILLS CERT.OFAU .129296 .X1Swo", 1070 TECHNOLOGY DRIVE VERTICAL SECTION B-B N.VENICE,FL 34275 t -I FPA-5560.0 A,L'N"'R'P.E' 1(941)480-1600 DH-5560 NTS 3 OF 4 � S i i f+-- EDGE DISTANCE SHOWN INSTALLED SHOWN INSTALLED I SHOWN INSTALLED THROUGH THE THROUGH THE i THROUGHTHE - FRAME INTEGRAL FIN j FRAME - /�l�Q —�}- EMBEDMENT EDGE DISTANCE FIN FRAME FRAME - �.....- i EMBEDMENT SHOWNI — _ 114"MAX SHIM 1!4"MAX SHIM Q' 114'MAX SHIM i �� BOTTOM SASH ! Jr EMBEbMENT EDGE q DISTANCE III roP J ( ! 0 SASH EXTERIOR FIN t FRAME OPT.SASH TOP J-CHANNEL SHOWN ([j 'j( � i-�7 LIFT RAIL FRAME 'r SHOWN BUCK WIDTH --^------r� O HORIZONTAL SECTION C-C I HEIiGHT �( i -- j"'--• 114'MAX.SHIM }w- 114"MAX.SHIM ' I INSTALLATION NOTES: 3 U! 1)SEE SHEET 1 FOR SPACING I < REQUIREMENTS. 2)SEE TABLE(S)ON SHEET 2 FOR ANCHORAGE AND SUBSTRATE EXTERIOR `I REQUIREMENTS. 3)MAX.SHIM THICKNESS TO BE 114". 4)GLASS SHOWN IS FOR I ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN I REQUIREMENTS. FIN 13 FIN O OPT.SASH -Ills 6)FIN AND/OR FLANGE MAY BE j REMOVED TO CREATE OTHER J-CHANNEL BOTTOM LIFT - FRAME TYPES. f FRAME RAIL r i + FRAME1I FRAME SHOWN EXTERIOR SHOWN 1 ---'� RIOR SHOWN ,Y j r r v a� 114,MAX INSTALLATION THROUGH INSTALLATION THROUGH THE 0� SHIM THE FRAME.INTO METAL INTEGRAL FIN,INTO METAL `\�,. .......... 11 EDGE L D DISNCE FPA(IMP.-RESIST.) ` 12/13!14 - �1���31�;• `• SHOWN -•-f��— �- TAo INSTALLED EDGE j J"CHANNEL&INTEGRAL FIN FRAMES o, ROSOWSKI , '� l� IS •' ;'' i-- THROUGH DISTANCE sJr INTEGRAL FIN EMBEDMENT -- _ CERT.OF AUTH.828298 x $ ,�_j,i•,,,F•+')�,��?.•',t.,; 1 ``.::.. VERTICAL SECTION D-D 1070 TECHNOLOGY DRIVE t, �o N.VENICE,FL 34275 e - d A.LYNN MILLER,P.E. (941)-480-1600 DH-5560 N NTS h 4 OF 4 i FPA-5560.0 a P.Ep 68705 r 1