HomeMy WebLinkAboutProduct Approval Business & Professional: e
Holda Departments BCIS Home I Log In I user Registration I Hot Topics Submit Surcharge Stats&Facts I Publications FBC Staff BCIS Site Map Links Search
Busines ��
Professi I SER Pu li ar°"a'
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
r o FL# FL17322-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Atlas Roofing Corporation
Address/Phone/Email 2000 RiverEdge Parkway
Suite 800
Atlanta,GA 30328
(770)946-4571
mcollins@atlasroofing.com
Authorized Signature Meldrin Collins
mcollins@atlasroofing.com
Technical Representative
Add ress/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
k Validation Checklist- Hardcopy Received
Certificate of Independence FL17322 RS COI ATL14001.1 2014 FBC Evaluation Report Atlas
Underlavments.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D 226 2006
ASTM D 2626 2004
ASTM D 4869 2005
ASTM D 6380 2003
TAS 103 1995
TAS 110 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2015
Date Validated 04/20/2015
Date Pending FBC Approval 04/23/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
17322.1 Atlas Underlayments For use in steep slope roofing
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17322 Ri II ATL14001.1 2014 FBC Evaluation Report
Approved for use outside HVHZ:Yes Atlas Underlayments.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
other:See evaluation report for limits of use. Evaluation Reports
FLi7322 R1 AE ATL14001.1 2014 FBC Evaluation Report
Atlas Underlavments.odf
Created by Independent Third Party: Yes
6acic PJext
Contact Us::1940 North Monroe Street,Tallahassee FL 32349 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click-here. — --
Product Approval Accepts:
RX a-cAtsfc M
SfCltrl 'StIiTItiCS'
CREEK Certificate of Authorization No.29824
17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: ATLAS ROOFING CORPORATION Issued April 19,2015
2000 Riveredge Parkway,Suite 800
Atlanta,GA 30328
(770)612-6267
www.atiasroofina.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1,1507.4.5.2,
1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1507.6.5,1507.7.3,
1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8,T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5,
1507.9.9,1518.4, 1523.1.1, 1523.6.5.2.1
Properties: Physical properties
REFERENCES
Enty Report No. Standard Year
PRI Construction Materials Technologies(TST6049) ATL-033-02-01 ASTM D 226 2006
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 TAS 110 2000
PRI Construction Materials Technologies(TST6049) ATL-069-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) ATL-090-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) ATL-149-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) ATL-164-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-006-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-029-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 110 2000
PRI Construction Materials Technologies(TST6049) NEI-046-02-01 Tensile Adhesion 2007
PRI Construction Materials Technologies(TST6049) NEI-062-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-063-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-063-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) NEI-063-02-01 TAS 110 2000
PRI Construction Materials Technologies(TST6049) NEI-076-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-076-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) NEI-076-02-01 TAS 110 2000
UL LLC(TST1740) 02-NK40952 ASTM D 1970 2009
UL LLC(TST1740) 02-NK40952 ASTM D 226 2006
UL LLC(TST1740) 02-NK40952 ASTM D 2626 2004
UL LLC(TST1740) 02-NK40952 ASTM D 4869 2005e01
UL LLC(TST1740) 02-NK40952 ASTM D 6380 2003(2009)
ATL14001.1 FL17322-R1 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
#15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
#30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
#90 Mineral Surface Roll ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
Roofing HVHZ and non-HVHZ.
Gorilla Guard®EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ and
non-HVHZ.
Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMaster0 Granular ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster®Polyseal ASTM D 1970 SBS modified, self-adhering underlayment with a poly-fabric
surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered
with a release film,which is removed during installation.
WeatherMaster®TU Ultra ASTM D 1970 and TAS 103 SBS modified, self-adhering underlayment with a
non-woven polyester fabric surface for use in the non-HVHZ and HVHZ. The self-
adhesive side is covered with a release film,which is removed during installation.
WeatherMaster®200 SE ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split-release film, which is removed during
installation.
WeatherMaster®Film SE ASTM D 1970 SBS modified,self-adhering underlayment with plastic film surface
for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a
split-release film,which is removed during installation.
WeatherMaster®Granular SE ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@ PolySeal SE TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat
reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster®TUUltra SE TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat
reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
—`—` --`installation.
ATI-14001.1 FL17322-R1 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK
ATLAS ROOFING CORPORATION
jj Roofing Underlayments
TECHNICAL SERVICES, LLC
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt,#30 Specification Felt, and #40 Base Sheet -exposure for than 24 hours may
adversely affect product performance
b) WeatherMaster0 Granular SE or WeatherMaster0 Granular-maximum 14 days
c) WeatherMaster@ Polyseal SE and WeatherMaster0 TU Ultra SE-maximum 90 days
d) WeatherMaster0 TU Ultra-maximum 180 days
Self-adhering underlayments may be adhered to the following substrates as follows in the non-HVHZ:
a) WeatherMasterO Granular, WeatherMasterO Polyseal, or WeatherMaster0 TU Ultra - primed
concrete,plywood,primed plywood,OSB,or primed OSB
b) WeatherMasterO Granular SE, WeatherMaster® Polyseal SE, or WeatherMaster0 TU Ultra SE -
plywood or primed plywood
c) WeatherMaster0 Granular or WeatherMasterOO TU Ultra-DensDeck Prime
d) WeatherMaster0 Polyseal-ACFoam HS
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents):
a) WeatherMasterO TU Ultra-Convenience Products Touch n' Seal Storm Bond Roof Tile Adhesive or
3M 2-Component Roof Tile Adhesive AH-160
b) WeatherMaster0 Polyseal SE or WeatherMastert) TU Ultra SE-3M 2-Component Roof Tile Adhesive
AH-160
c) Slate/Tile Underlayment or#90 Mineral Surface Roll Roofing - Convenience Products Touch n' Seal
Storm Bond Roof Tile Adhesive,Dow TileBond, or 3M.2-Component Roof-Tile-Adhesive-AH-1 60
Allowable Roof Coverings:
Metal Roof Wood
Asphalt Panels and Composite Shingles and Slate Clay and
Underlayment Shingles Shingles Shingles Shakes Shingles Concrete Tile
#15 Specification Felt Y Y Y Y Y N
#30 Organic Saturated Felt Y Y Y Y Y N
#30 Specification Felt Y Y Y Y Y Y
#43 Base Sheet Y Y Y Y Y Y
#90 Mineral Surface Roll Roofing Y' N N N N Y
Gorilla Guard®EVERFELT 30 Y Y Y Y Y N
Slate/Tile Underlayment Y, N N N N Y
WeatherMaster®Granular Y N Y Y Y N
WeatherMaster®Polyseal Y Y Y Y Y N
WeatherMaster®TU Ultra Y Y Y Y Y Y
WeatherMasterw?200SE Y N Y Y Y N
WeatherMaster®Film SE Y Y Y Y Y N
WeatherMaster®Granular SE Y N Y Y Y N
WeatherMasterO Polyseal BE Y Y Y Y Y Y
WeatherMasterSTU Ultra SE Y Y Y Y Y Y
Notes,=1}Gpen�ralIeyzappIicationsper=1207-2.-9.-2
ATL14001.1 FL17322-R1 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREAK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Minimum roof slope shall be in accordance with FBC requirements.
4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources,the more restrictive and FBC
compliant installation detail shall prevail.
5) Products described within this report may be used as described in other current FBC product approval
documents.
6) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
`�e%%�PRY R. p���i��
=',ti�.''•`'�GENSF 2015.04.19
No 74021
= *� * = 14:19:46
13STATE OF :�4 -04�00�
O'•.
Zachary R.Priest,P.E.
, O R, G\`. Florida Registration No.74021
-0NA� �'� Organization No.--ANE9641 - - -
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R.Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
ATL14001.1 FL17322-RI Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.