Loading...
HomeMy WebLinkAboutProduct Approval Business & Professional: e Holda Departments BCIS Home I Log In I user Registration I Hot Topics Submit Surcharge Stats&Facts I Publications FBC Staff BCIS Site Map Links Search Busines �� Professi I SER Pu li ar°"a' Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail r o FL# FL17322-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta,GA 30328 (770)946-4571 mcollins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Add ress/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden k Validation Checklist- Hardcopy Received Certificate of Independence FL17322 RS COI ATL14001.1 2014 FBC Evaluation Report Atlas Underlavments.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D 226 2006 ASTM D 2626 2004 ASTM D 4869 2005 ASTM D 6380 2003 TAS 103 1995 TAS 110 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2015 Date Validated 04/20/2015 Date Pending FBC Approval 04/23/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 17322.1 Atlas Underlayments For use in steep slope roofing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL17322 Ri II ATL14001.1 2014 FBC Evaluation Report Approved for use outside HVHZ:Yes Atlas Underlayments.pdf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes other:See evaluation report for limits of use. Evaluation Reports FLi7322 R1 AE ATL14001.1 2014 FBC Evaluation Report Atlas Underlavments.odf Created by Independent Third Party: Yes 6acic PJext Contact Us::1940 North Monroe Street,Tallahassee FL 32349 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click-here. — -- Product Approval Accepts: RX a-cAtsfc M SfCltrl 'StIiTItiCS' CREEK Certificate of Authorization No.29824 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: ATLAS ROOFING CORPORATION Issued April 19,2015 2000 Riveredge Parkway,Suite 800 Atlanta,GA 30328 (770)612-6267 www.atiasroofina.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1,1507.4.5.2, 1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1507.6.5,1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8,T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9,1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Enty Report No. Standard Year PRI Construction Materials Technologies(TST6049) ATL-033-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) ATL-068-02-01 TAS 110 2000 PRI Construction Materials Technologies(TST6049) ATL-069-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) ATL-090-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) ATL-149-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) ATL-164-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-006-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-029-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 110 2000 PRI Construction Materials Technologies(TST6049) NEI-046-02-01 Tensile Adhesion 2007 PRI Construction Materials Technologies(TST6049) NEI-062-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-063-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-063-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) NEI-063-02-01 TAS 110 2000 PRI Construction Materials Technologies(TST6049) NEI-076-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-076-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) NEI-076-02-01 TAS 110 2000 UL LLC(TST1740) 02-NK40952 ASTM D 1970 2009 UL LLC(TST1740) 02-NK40952 ASTM D 226 2006 UL LLC(TST1740) 02-NK40952 ASTM D 2626 2004 UL LLC(TST1740) 02-NK40952 ASTM D 4869 2005e01 UL LLC(TST1740) 02-NK40952 ASTM D 6380 2003(2009) ATL14001.1 FL17322-R1 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard®EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ and non-HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster0 Granular ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster®Polyseal ASTM D 1970 SBS modified, self-adhering underlayment with a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film,which is removed during installation. WeatherMaster®TU Ultra ASTM D 1970 and TAS 103 SBS modified, self-adhering underlayment with a non-woven polyester fabric surface for use in the non-HVHZ and HVHZ. The self- adhesive side is covered with a release film,which is removed during installation. WeatherMaster®200 SE ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster®Film SE ASTM D 1970 SBS modified,self-adhering underlayment with plastic film surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film,which is removed during installation. WeatherMaster®Granular SE ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ PolySeal SE TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster®TUUltra SE TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during —`—` --`installation. ATI-14001.1 FL17322-R1 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION jj Roofing Underlayments TECHNICAL SERVICES, LLC APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt,#30 Specification Felt, and #40 Base Sheet -exposure for than 24 hours may adversely affect product performance b) WeatherMaster0 Granular SE or WeatherMaster0 Granular-maximum 14 days c) WeatherMaster@ Polyseal SE and WeatherMaster0 TU Ultra SE-maximum 90 days d) WeatherMaster0 TU Ultra-maximum 180 days Self-adhering underlayments may be adhered to the following substrates as follows in the non-HVHZ: a) WeatherMasterO Granular, WeatherMasterO Polyseal, or WeatherMaster0 TU Ultra - primed concrete,plywood,primed plywood,OSB,or primed OSB b) WeatherMasterO Granular SE, WeatherMaster® Polyseal SE, or WeatherMaster0 TU Ultra SE - plywood or primed plywood c) WeatherMaster0 Granular or WeatherMasterOO TU Ultra-DensDeck Prime d) WeatherMaster0 Polyseal-ACFoam HS Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMasterO TU Ultra-Convenience Products Touch n' Seal Storm Bond Roof Tile Adhesive or 3M 2-Component Roof Tile Adhesive AH-160 b) WeatherMaster0 Polyseal SE or WeatherMastert) TU Ultra SE-3M 2-Component Roof Tile Adhesive AH-160 c) Slate/Tile Underlayment or#90 Mineral Surface Roll Roofing - Convenience Products Touch n' Seal Storm Bond Roof Tile Adhesive,Dow TileBond, or 3M.2-Component Roof-Tile-Adhesive-AH-1 60 Allowable Roof Coverings: Metal Roof Wood Asphalt Panels and Composite Shingles and Slate Clay and Underlayment Shingles Shingles Shingles Shakes Shingles Concrete Tile #15 Specification Felt Y Y Y Y Y N #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y Y Y Y #90 Mineral Surface Roll Roofing Y' N N N N Y Gorilla Guard®EVERFELT 30 Y Y Y Y Y N Slate/Tile Underlayment Y, N N N N Y WeatherMaster®Granular Y N Y Y Y N WeatherMaster®Polyseal Y Y Y Y Y N WeatherMaster®TU Ultra Y Y Y Y Y Y WeatherMasterw?200SE Y N Y Y Y N WeatherMaster®Film SE Y Y Y Y Y N WeatherMaster®Granular SE Y N Y Y Y N WeatherMasterO Polyseal BE Y Y Y Y Y Y WeatherMasterSTU Ultra SE Y Y Y Y Y Y Notes,=1}Gpen�ralIeyzappIicationsper=1207-2.-9.-2 ATL14001.1 FL17322-R1 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREAK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Minimum roof slope shall be in accordance with FBC requirements. 4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources,the more restrictive and FBC compliant installation detail shall prevail. 5) Products described within this report may be used as described in other current FBC product approval documents. 6) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. `�e%%�PRY R. p���i�� =',ti�.''•`'�GENSF 2015.04.19 No 74021 = *� * = 14:19:46 13STATE OF :�4 -04�00� O'•. Zachary R.Priest,P.E. , O R, G\`. Florida Registration No.74021 -0NA� �'� Organization No.--ANE9641 - - - CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL14001.1 FL17322-RI Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.