Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 aU .Meo,a ' 0 R f d , 'd a Depai tm..nt,: rc BCIS Home Log In ' User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links i Search usines �) Professional {��I � PEoduPublic Approval User Regulation RECEIVE Product Approval Menu>Product or Aoolication Search>Application List>Application Detail >fl JUL 2 9'203 a.. FL# FL10674-R9 Application Type Revision Code Version 2010 Application Status Approved Comments Archived - Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway . Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owen.scorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/17/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R9 COI 2014 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2007 Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 12/29/2014 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/28/2014 Date Validated 03/05/2014 Date Pending FBC Approval 03/05/2014 Date Approved 04/18/2014 ':Summary of Products FL IlModel,Number or Name IlDescription 10674.1 =FOwens Corning Asphalt Roofing 3-tab,4-tab, 5-tab, laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R9 II 2014 03 FINAL OC Asphalt Approved for use outside HVHZ:Yes Shingles FL10674-R9.pdf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R9 AE 2014 03 FINAL OC Asphalt Shingles FL10674-R9.pdf Created by Independent Third Party: Yes Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ® hxt ® sLLuritvm i,Cn ics http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 12/29/2014 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 l TR�N�TY ERD 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R4 One Owens Corning Parkway FL10674-R9 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 4: 03/04/2014 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 03/04/2014 -�' This does not serve as an electronically signed Robert J.M. Nieminen P.E. •''%,�s,:;_' 'o' c' document. Signed,sealed hardcopies have been transmitted to the Florida Registration No. 59166, Florida DCA ANE1983 �""""" to the named I enProdud Approval Administrator and CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinityiERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals &Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals &Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals &Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme° are fiberglass reinforced; 3-tab asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire TM are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration@, TruDefinition° DurationO, Duration® Premium Cool, TruDefinitionO Durationo Designer Color Collection, TruDefinitionO Oakridge®, Oakridge° and WeatherGuardO HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardo HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4: 03/04/2014 Page 2 of 7 -fRINITY ERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: Berkshires shingles require minimum five (5) nails per shingle. > WeatherGuard® HP shingles require minimum six (6) nails per shingle. > Devonshire TM shingles require minimum six (6) nails per shingle. > Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4: 03/04/2014 Page 3 of 7 TRINITY ERD 6.2.5 Minimum Nailing — Classic@ &Supreme: r r Normal Mansard or Area pare Normal Mansard or Area para Wind Areas High Wind desvenes y Wind Areas High Wind desvenes y Area para vientos normales Areas vientos fueKes Area pars vientos nonnales Areas vientos fuertss t.1t• (A) 77,1" r1" 2' (B ✓2' r2. t. 12 wet2 1 1 5"Exposure S 5/8'Exposure Exposition Exposici in 6.2.6 Minimum Nailing — Berkshire@: Sealant strip Sealars strip Ca tLa de seaada !a tka da sdlarbr 1— �}t--►a�---) a {---► a 9 )a 04------64--------*e • 64----------*• 9 Yf 9 Yf B Yt t B Yt B Yi' B Y B 1. t•J 1' t"J r r r Asphalt roofrtg cement Cemeeto de techode aslafto 6.2.7 Minimum Nailing — Devonshire TM: Nails Nails Ten 1"Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing — Duration@, TruDefinition@ Duration, Duration@ Premium Cool & TruDefinitionO DurationO Designer Color Collection: 4 Nal Pattern 6 Nail kb%rdaid$tn;Sion }as'rn benreer Wariar9 Esquema de 4 davos Pattern arra andtd;U cut eL4. Esquema — �='dr-rdE reS SuRNal tntening ar•a width de 6 davos agkrs§ erre sr Area dodawsSureNafle e a e :re S, "3tarbpand sgtnafraae. 1• 1• Suretla3'� N SueYti!' tastemff9!�� tastm�qq arta riidiri 3r[a 9CiQti 12' 12• /iP.a de 1• �a SUttt'i� t_ 1Z' 12" sa ja�p 5%'Exposure Was 5 •� �° 9.4 ping.de exposidcn paws 5SS ping.de exposkidn W"Exposure Nais 5W Exposure 5!5 ping,do exposkl6n darns 54 pulg.do rxpnsidda Exterior Research and Design, LLC. Evaluation Report 037940.02.12-1114 Certificate of Authorization#9503 FL10674-R9 Revision 4: 03/04/2014 Page 4 of 7 TRINITY ERD 6.2.9 Minimum Nailing —TruDefinitionOOakridge@, Oakridge@: 4 Nail Pattern 6 Nail Pattern Esquema con 4 cfavos Esquema con 6 cfavos r t. r r tz• I� tr --il IF— 55/9"Exposure 5 5/9"Exposure Ex osiadn de 55/8 u; NailsEx s!eidn de 55/8 u!. 5 5/9"Ex osuie Naos 5 5/9"Ex P P g- Clavus Po P 9 P Clavus Posure Exposludn de 55/6 ping. Exposicidn de 55/8 pulg. 6.2.10 Minimum Nailing — WeatherGuard@ HP: 1 single side view rmum Thmu*Ndl lb cfM w it ier ab 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgell Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-114 Certificate ofAuthorization#9503 FL10674-R9 Revision 4: 03/04/2014 Page 5 of 7 ^ ' ` -- TRoNUTY ERD 6J.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge: Direction Nails Nals 7' Top Larninated Piece Expusme 6.3.4 Minimum Nailing - Hip 8Ridge with Sealant: tem Fig. 2 - High Wind Fastening Pattem (4 Nails) 'rim Shingle and Discard Excess 2�1 I' Sealant — Strip 12" Fastening 511s 5"Exposure 6.3.5 Minimum Nailing - VVeatherGuandU0 MP Hip and Ridge: Fig.A Prmillng Wind Fig.C Hip&Ridge Shingle Fastening .4- TopMw Direction Q Nails Nails Exposure Exposure IN Exterior Research and Design, LLC. Evaluation Report ms794o.oa.10-R4 Certificate prxumurizauon#esos pL10674+11e Revision 4` os/04/z014 Page 6nf 7 f TRINITY ERD 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Standard -11"- Wind Direction Fastening Sealant Strip Pattern 6°Exposure7° I-� hl I- V 72 I ttt Sealant Fasten 71h' 7 6"Exposure Cover Exposed { Fasteners with Roof Cement 1-12' 6.3.7 Minimum Nailing — DuraRidgell Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. PrasaiintWnd Diraceon Top View Diremon domirante di voltVue en plan Direcd6ndel rientapredcrnirente II' Visca='ralor I-H t. \\ Clou n' ��r Ovrcns Corrir I surcNatT Naik _—� — Slom —t""I I c.Iaror� I I � I I Iia. "ice` P I� 12_ `I 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this.product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann(a-)ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate ofAuthorization#9503 FL10674-R9 Revision 4: 03/04/2014 Page 7 of 7