Product Approval Menu>Product or Aoolication Search>Application List>Application Detail >fl JUL 2 9'203
a.. FL# FL10674-R9
Application Type Revision
Code Version 2010
Application Status Approved
Comments
Archived -
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway .
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owen.scorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who Robert J.M. Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/17/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R9 COI 2014 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161, Class F 2006
ASTM D3462 2007
ASTM D7158, Class H 2007
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 12/29/2014
Florida Building Code Online Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/28/2014
Date Validated 03/05/2014
Date Pending FBC Approval 03/05/2014
Date Approved 04/18/2014
':Summary of Products
FL IlModel,Number or Name IlDescription
10674.1 =FOwens Corning Asphalt Roofing 3-tab,4-tab, 5-tab, laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R9 II 2014 03 FINAL OC Asphalt
Approved for use outside HVHZ:Yes Shingles FL10674-R9.pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other: Refer to ER, Section 5. Evaluation Reports
FL10674 R9 AE 2014 03 FINAL OC Asphalt
Shingles FL10674-R9.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.
'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® hxt ®
sLLuritvm i,Cn ics
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 12/29/2014
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
l TR�N�TY ERD 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R4
One Owens Corning Parkway FL10674-R9
Toledo, OH 43659 Date of Issuance: 02/06/2012
Revision 4: 03/04/2014
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
The facsimile seal appearing was authorized
by Robert Nieminen,P.E.on 03/04/2014
-�' This does not serve as an electronically signed
Robert J.M. Nieminen P.E. •''%,�s,:;_' 'o' c' document. Signed,sealed hardcopies have been
transmitted to the
Florida Registration No. 59166, Florida DCA ANE1983 �""""" to the named I enProdud Approval Administrator and
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinityiERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007
3. REFERENCES:
Entity Examination Reference Date
UL LLC (CER9626) Physicals &Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals &Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals &Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme° are fiberglass reinforced; 3-tab asphalt roof shingles.
4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire TM are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration@, TruDefinition° DurationO, Duration® Premium Cool, TruDefinitionO Durationo
Designer Color Collection, TruDefinitionO Oakridge®, Oakridge° and WeatherGuardO HP are
fiberglass reinforced, laminated asphalt roof shingles.
4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardo HP Hip
& Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip & Ridge Shingles are
fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 2 of 7
-fRINITY ERD
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,it = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
Berkshires shingles require minimum five (5) nails per shingle.
> WeatherGuard® HP shingles require minimum six (6) nails per shingle.
> Devonshire TM shingles require minimum six (6) nails per shingle.
> Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 3 of 7
TRINITY ERD
6.2.5 Minimum Nailing — Classic@ &Supreme:
r r
Normal Mansard or Area pare Normal Mansard or Area para
Wind Areas High Wind desvenes y Wind Areas High Wind desvenes y
Area para vientos normales Areas vientos fueKes Area pars vientos nonnales Areas vientos fuertss
t.1t• (A) 77,1" r1" 2' (B ✓2' r2. t.
12 wet2 1
1
5"Exposure S 5/8'Exposure
Exposition Exposici in
6.2.6 Minimum Nailing — Berkshire@:
Sealant strip Sealars strip
Ca tLa de seaada !a tka da sdlarbr
1— �}t--►a�---) a {---► a 9 )a 04------64--------*e • 64----------*•
9 Yf 9 Yf B Yt t B Yt B Yi' B Y B
1. t•J 1' t"J
r
r
r
Asphalt roofrtg cement
Cemeeto de techode aslafto
6.2.7 Minimum Nailing — Devonshire TM:
Nails
Nails Ten 1"Spots of Asphalt Roof Cement
6.2.8 Minimum Nailing — Duration@, TruDefinition@ Duration, Duration@ Premium Cool &
TruDefinitionO DurationO Designer Color Collection:
4 Nal Pattern 6 Nail kb%rdaid$tn;Sion
}as'rn benreer Wariar9
Esquema de 4 davos Pattern arra andtd;U cut eL4.
Esquema — �='dr-rdE reS
SuRNal tntening ar•a width de 6 davos agkrs§ erre sr
Area dodawsSureNafle e a e :re S, "3tarbpand
sgtnafraae.
1• 1• Suretla3'� N SueYti!'
tastemff9!�� tastm�qq
arta riidiri 3r[a 9CiQti
12' 12• /iP.a de 1• �a
SUttt'i� t_ 1Z' 12" sa ja�p
5%'Exposure
Was 5 •� �°
9.4 ping.de exposidcn paws 5SS ping.de exposkidn
W"Exposure Nais 5W Exposure
5!5 ping,do exposkl6n darns 54 pulg.do rxpnsidda
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-1114
Certificate of Authorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 4 of 7
TRINITY ERD
6.2.9 Minimum Nailing —TruDefinitionOOakridge@, Oakridge@:
4 Nail Pattern 6 Nail Pattern
Esquema con 4 cfavos Esquema con 6 cfavos
r t.
r r
tz•
I� tr --il IF—
55/9"Exposure 5 5/9"Exposure
Ex osiadn de 55/8 u; NailsEx s!eidn de 55/8 u!. 5 5/9"Ex osuie Naos 5 5/9"Ex
P P g- Clavus Po P 9 P Clavus Posure
Exposludn de 55/6 ping. Exposicidn de 55/8 pulg.
6.2.10 Minimum Nailing — WeatherGuard@ HP:
1 single side view
rmum Thmu*Ndl lb
cfM w it ier ab
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply
with the manufacturer's current published instructions, using four (4) nails per shingle.
Installation of DuraRidgell Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing
for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-114
Certificate ofAuthorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 5 of 7
^
'
`
--
TRoNUTY ERD
6J.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge:
Direction
Nails Nals
7' Top Larninated
Piece
Expusme
6.3.4 Minimum Nailing - Hip 8Ridge with Sealant:
tem Fig. 2 - High Wind Fastening Pattem
(4 Nails)
'rim Shingle
and Discard
Excess 2�1 I'
Sealant —
Strip 12"
Fastening 511s 5"Exposure
6.3.5 Minimum Nailing - VVeatherGuandU0 MP Hip and Ridge:
Fig.A Prmillng Wind Fig.C Hip&Ridge Shingle Fastening
.4- TopMw
Direction Q
Nails Nails
Exposure
Exposure
IN
Exterior Research and Design, LLC. Evaluation Report ms794o.oa.10-R4
Certificate prxumurizauon#esos pL10674+11e
Revision 4` os/04/z014
Page 6nf 7
f
TRINITY ERD
6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing Standard -11"-
Wind Direction Fastening
Sealant Strip Pattern
6°Exposure7° I-� hl I- V
72 I ttt Sealant
Fasten 71h' 7 6"Exposure
Cover Exposed {
Fasteners with
Roof Cement
1-12'
6.3.7 Minimum Nailing — DuraRidgell Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to
Owens Corning published installation instructions for their minimum requirements.
PrasaiintWnd Diraceon Top View
Diremon domirante di voltVue en plan
Direcd6ndel rientapredcrnirente II' Visca='ralor I-H
t.
\\ Clou
n' ��r Ovrcns Corrir I surcNatT
Naik _—� —
Slom —t""I I
c.Iaror� I I
� I I
Iia.
"ice`
P I� 12_
`I
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this.product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann(a-)ul.com
- END OF EVALUATION REPORT -