Loading...
HomeMy WebLinkAboutEngineering TURQUOISE Engineering, LLC Structural Engineering, Design & Testing, CA#28948, NOA#13-0222.02 6915 Washington Rd,West Palm Beach, FL 33405/Phone(561)804-9908/Fax(561)804-9907/e-mail:turginc@aol.com July 30, 2015 TO: St. Lucie County / Building Department FROM: Riza N. ALTAN, P.E. SUBJECT: Flat Roof Uplift Pressures & Base Sheet Enhanced F..r ADDRESS: Residence for Deutsche Bank Trust;Co. 2994 Conifer Dr., Ft Pierce, FL 34982 CONTRACTOR: Larry Neese Roofing, LLC Dear Sir: The re-roofing specifications for flat roof areas of the subject residence are rev ie3ED myself. The purpose of this letter is to determine the wind uplift pressures and ene spacing of the mechanical fasteners. The one-story-high property is located in Exposure C area. The flat roof areas consist of and 5/8" plywood deck with positive drainage. The roof mean height is 10 ft. As per the 2014 Florida Building Code, ASCE 7-10, 165 MPH ultimate wind velocity for Risk Category II in Exposure C area, using Wind Load Factor of 0.6 for ASD; the wind pressures are determined as follows: Field: P1 = -44 psf . / Perimeter (4'wide): P2 = - 74 psf / Corner (4'x4'): P3 = -111 psf The proposed CertainTeed Modified Bitumen Roof System over Wood Decks (NOA #14-0224.03) consists of mechanically attached Empire-All Weather Base base sheet, followed by torched-down FlintLastic GTA modified bitumen cap sheet. The system max. design pressure of -60 psf (Deck 1I, Syst.E(3), page 14116, Limitation #7) is specified by tin-tagging the base sheet with 11 ga., 1'/4" long ring-shanked roofing nails, spaced at 811o.c. along the laps and 811o.c., three rows staggered in mid-sheet. It is required that, as per RAS 117 in order to meet the actual roof pressures, the base sheet is tin-tagged to the existing wood decks in the following enhanced pattern: Zone 1: Field (Intermediate areas): @ 8"o.c., staggered three rows in mid-sheet Zone 2: Perimeter (4' from edges): @ 6"o.c., staggered three rows in mid-sheet Zone 3: Corner (4' from ea. side): @ 4"o.c., staggered three rows in mid-sheet Laps: Field (4"min.): @ 8"o.c., Perimeter @ 611o.c. & Corners: @ 411o.c. Therefore, this letter is to certify that installation of CertainTeed Modified torched-down -_ Bitumen Roof System (NOA #14-0224.03) conforms to the requirements ,of-the -2014_ Florida Building Code which specifies 165 MPH ultimate wind speed for Risk Category II ly,fARMure C area. ���E N. At, ®�0, i, \ •1es2•e pD . If you have any questions regarding this matter or I may be of further-assS`tan�r�',,& e°°do �� not hesitate to call me. y _+ N,.38521` Sincerely, L a _ STRTE-OF" == _+ Riza N. ALTAN, P. 38521s/0NA . s � Consulting Engineer gc �g4