Loading...
HomeMy WebLinkAboutEngineering FL® A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866) 784-8550 wwar.floridaengineeringandtesting.com 250 S.W.13th Avenue Pompano Beach,FL 33069 DATE: 7/30/15 JOB ORDER#: 15-2456 CLIENT: All Area Roofing ADDRESS: 3921 S.US Highway 1 Fort Pierce,Florida 34982 PROJECT: Lawrence Residence Flat Non-Insulated Wood Deck ADDRESS: 6501 Santa Clara Blvd. Fort Pierce,Florida FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Height= 15' Exposure: C Basic/Ultimate Wind Speed: Vuit=170 mph Length= 27' Category: H Nominal Wind Speed: V.d=Vuit*40.6 Width= 13' Slope: <7° (asd=allowable strength design) Parapet Wall: <3' Residential KZ=0.85,Kzt= 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q= 0.00256*KZKaKdV2 Velocity Pressure („it): q=0.00256(0.85)(1.0)(0.85)(170)2] =53.45 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*x0.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(13') = 1.3' 0.4(15') = 6.0' } use: 3'0" Effective Wind Area: <10A2 For parapet height three feet(3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 I I I '-'r % iQ u. Qrfff ty�-:6'Ag4saacrance Page 2,7/30/15,Job Order#15-2456 • All Area Roofing F1,01VIPA Lawrence Residence-Flat Non-Insulated Wood Deck 6501 Santa Clara Blvd.; Fort Pierce,FL: r• Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0)—(0.18)] =-37.8 psf 2) Perimeter P2 = 32.07*[(-1.8)—(0.18)] =-63.5 psf 3) Corners P3 = 32.07*[(-2.8)—(0.18)] =-95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #14-0224.03, System Type E(1),pg 12 of 16,with a maximum design pressure of -52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non-insulated) deck utilizing approved 11 ga. annular ring shank nails and approved tin caps: Field: 8" o.c. @ 4" laps and 3 staggered rows 8" o.c. Perimeter: 8" o.c. @ 4" laps and 4 staggered rows 8" o.c. Corners: 6" o.c. @ 4" laps and 5 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a=3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, Reza idan,P.E. Florida Engineering&Testing, Inc. Florida Reg.No. 60223 Certificate of Authorization No. 6923