Loading...
HomeMy WebLinkAboutProduct Approval rTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: gnim Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&•Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition' Duration', Duration® Premium Cool, TruDefinition® Duration' Designer Color Collection, Tru Definition'Oakridge',Oakridge®and WeatherGuard'HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(Vit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-RS Certificate of Autharizatian#9503 FL10674-R10 Revision 5:04/22/2015 Page 2 of 6 QOTRINITYJ ERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle. ➢ DevonshireTM shingles require minimum six(6)nails per shingle. ➢ Starter Strip Plus requires minimum five(S)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pare Normal Mansard or Area pare Wind Areas High Wind desvenes y Wind Areas High Wind deavenes y A es pare vientos nermates Areas vientos fuertes Area porn vientos normeies Areas vientos fuertes. rt" 2`1 IB z• t• t" (Al t" t z" ' 2 r ILtr tr tzt tzt r IB r S'Exposure 5 5/8"Exposure Exposici6n Exposici6n 6.2.6 Minimum Nailing—Berkshire": Sealant strip Sealant strip La Ura de soda La fka do sdladbi t" a 4 a--iii---► s'e , 6 —► �s —s• 'a�--—► —�• 8 Vi" 9 V 9V 8 VT 8 Yf 8 t/f 8 Yt° 8 Yf to r . 1 r.� 2" Asphaft roofing oemenl Cemento dot&ho de astano Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R5 Certtficate of Authorisation#9503 FL10674-R10 Revision 5:04/22/2015 Page 3 of 6 C-"YD TRINITY I ERD 6.2.7 Minimum Nailing—Devonshire—: a Nails r r s• K a• r r I r � t � .r 13-V Nails Ten T'Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing—Duration®,TruDefinition® Duration, Duration®Premium Cool&TruDefinition Duration Designer Color Collection: 4 Nail"Pattern;, 6 Nail NP sardandSleep slo teten Oehwm SureNa Esquema de 4 clavos Pattern area andtop d eut out. Es uenra opardierdes S,urellaila fastening area widthdo 6 claVOs , a"uof aArea.dedams SureNailo �W.Pe,h �l uparhr dal ranla. SunNaif° \ iP 1° 1� SureNa6Steiting9 � DStm'v9 Bred WiUttl � a1W Wiflh 12' - 1P'.—� dreada T. kea SmeNail° .� 1Z' 1TLE Sure;ai@' 5W Exposure Nails 55a"Exposure Uh'pufg.de'exposid6f? Davos 6a%pulg.de exp9sicf6n 5%"Exposure Nails 5V Exposure 51%pufg.deerposici6n Claws 5�Ap1lg.deerrposlelon 6.2.9 Minimum Nailing—TruDefinition®Oakridge®,Oakridge®: 4 Nall Pattem 8 Nail Pattern Esquena•con 4 clavos Esquema con 6 cfavos 1. 1. 1. r I<— ,z.. --1►I -,—�- � ,z- 55/8"Exposure Nails 5 518"Exposure Nails Exposid6n.de'65/8pulg. clavos Exp-Wn46618pufg. 5518"E>.posute Nails 55tH"Exposure Expaslddn de 66/Bpulg. Expasidon de 65/8pulg. 6.2.10 Minimum Nailing—WeatherGuard®HP: .S:••; :�::r'• Firrtone7lnw�r Mail lliw . __ C�u�wa�eri¢dfe Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorisation#9503 FL10674-R10 Revision 5:04/22/2015 Page 4 of 6 TRINITY I ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire'Hip and Ridge Shingles, High Ridge, Hip& Ridge with Sealant, WeatherGuard• HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidgell Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 t— PleuaiengliNntl Median p Topinav SideXrjm 'Nails Nails 4 TOP Lanlnatetl A I' Piece 1 I I I i I p I I I I osure I ul 1 I I I I I �tr I 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: 00 Fig_ :=.High W i d`f steln'rig RaPe►m' rim''Sh:ingl�' 6cCass Sealaint -- strip. ':Faayheti rlRg:. le S. Expasuire Distances 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig•t_prevailing Wind /� 44 Top Vlew olnictbn A A Nails p I I Nails Nails I 1 A I I T• 4 I I Z. I I I I V° 1• jk A � � I I • I I y 1 EVOCUM EIposum 8' Erposule I 12 Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-115 Certificate afAuthariratian 119503 FL10674-R10 Revision 5:04/22/2015 Page 5 of 6 TRINITY I ERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Sealant Strip Pattering A- - 6°Exposure I� wlwl I�2° a 12° 1 Sealant Fasten 7t(:°O\ 7tft° 1 6"Exposure Cover Exposed ISI_ 14 Fasteners with Roof Cement 6.3.7 Minimum Nailing—DuraRidge'"Hip&Ridge Shingles: l� Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Praraiing Wind Diratdm Top View Direction domimntackz nt _ �I- Vista a I' Diracd6n dal vitnto pradorninsnta r IN.1 Cbu n 2 j e Omns Costing SutcNail' Q_ x!12 1 1 C1swt\ 4 J J ala Iro Nk I P 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 CA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R5 Certificate of Authorization x/9503 FL10674-R10 Revision 5:04/22/2015 Page 6 of 6