Loading...
HomeMy WebLinkAboutProduct Approval .= t ij - MIAMI RADE COUNTY MIAMbQA®Efi v PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 248 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODEAi1A NISTRAIION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE(NOA) wnris.miamidade.gor•/economy �e, �eed�TCorpora�io�u 1400 Union Meeting Road,P.O.Boz 1100 Blue Bell,PA 19422-0761 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other area.0 where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have flus product or material tested for quality assures m purposes_If this product or material fails to perform in the accepted.manner, the manufacturer will incur.the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this a=epwnc-, if it is determined by MiamiDade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This,product is approved as descn'bed herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRII''I`ION:CeinTdil�trcdifi 'Bite :Roofingystsms over,Wood ITecks. LABELING:Each unit shall bear a permanent label with the manufictur&s name or logo,city,state and following statement:"Miami Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered atter a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or ifthere has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. 'INSPEC'lt ION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#13-0204.03 and consists of pages 1 through 16. The submitted documentation was reviewed by Alex Tigers. "MMADECOMUW" Expirat-ion Date:% f19 S--j Approval Date: 04/10/14 Page 1 of 16 Membrane Type: SBS Modified Deck Type 1L Wood,Insulated Deck Description: '9/32"or greater plywood or wood plank System Type A(2): Anchor sheet mechanically fastened,all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type VI)mechanically attached as detained below. Fastening. Anchor sheet shall be lapped 4"and fastened with I I ga.annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener able 3 Densitv/fe ACFoam IL;ENRGY 3,ENRGY 3 25 PSI,FlintBoard ISO,H,Shield Minimum 1.5"thick NIA NIA Approved Perlite Minimum'/."thiek N/A NIA Approved High Density Wood Fiberboard Minimum Y2"thick NIA ,N/A DensDeck,DensDeck Prime Minimum 114"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet.in full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbsJ100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment: Insolation_listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply.of All Mr/Einp ebbe Ultra Poly SMS,Glas Base,Flex I Glas Base,Flex I Glas FR Base or Poly SMS base adhered in a fWl mopping of approved asphalt applied within the EVT range and at a rate of 20-441bsJsq Ply Sheet: (Optional)One or more plies of Flintglas Ply Sheet(Type M.or Flintglas Premium Ply Sheet (Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq.or one ply of Black Diamond Base Sheet(for use with a torched cap sheet only)self-adhered NOA No.-14-0224.03 MIAMI DA►DE COUN CY Expiration Date: 06119/18 . • .. Approval Date. 04110114 Page 7 of 16 Membrane: One ply of Fliff IME Flintlastic GMS CoolStar,Flintlastic Premium GMS,.Flintlastic Premium GMS CoolStar, Flintlastic FR-P,Flintlastic FRP CoolStar,Flintlastic Premium FR- P,Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap sheet,Flintlastic FR Cap Sheet CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbsJsq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to base/ply sheet. Surfacing. (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 4004bJsq.gravel or 3004bJsq..slag in a flood coat of approved mopping asphalt at an application rate of 601bJsq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of I %Z gal./sq. Ma3dmum Design Pressure: -52!Sp-sf(See General Limitation 47) NOA No.:14-0224.03 M(AMFDADE COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/1.4 Page 9 of 16