Loading...
HomeMy WebLinkAboutEngineering ' R Chief Building Official August 4, 2015 St Lucie County Building Department 2300 Virginia Avenue Ft Pierce, FL 34982 Reference: Hodgens Residence 4700 Oleander Ave Fort Pierce, FL 34982 Subject: RAS-117 Nailing The roofer may secure the CertainTeed All Weather Empire base sheet, for Systems Type A(2),page 7/16 of NOA 14-0224.03, using 11 gauge annular ring shank nails and 1-5/8"dia. tin caps. Then tapered perlite insulation. The mechanical fastener spacing is as follows: Zone#1 (37 psf)—8" o.c. in the 4" lap and three rows, staggered, spaced 8" apart @ 8" O.C. Zone#2 (62 psf)—6" o.c. in the 4" lap and three rows, staggered, spaced 8" apart @ 6" o.c. Zone#3 (93 psf)—4" o.c. in the 4" lap and three rows, staggered, spaced 8" apart @ 4" o.c. All calculations are based on RAS-117 and the information contained in CertainTeed NOA 14-0224.03, expiring 06/19/2018. These fastening patterns will meet the structural criteria of the 2010 Florida Building code,with a"C" exposure during a 170 mph„It, 132 mph asd wind event. The cap sheet will be CertainTeed Flintlastic GMS. If you have any questions, please call me at your convenience. Tha U. _ Dr. Ernest A. Kuonen, PE 022920 President, The Erning Corporation CA-8327 802A Muirfield Court Jupiter, FL 33458