Loading...
HomeMy WebLinkAboutEngineering PAUL WELCH INC. P/I RECEIVED AUG 1410 Mechanical * Electrical * Civil Engineering CO 1984 S.W. Biltmore St. Suite#114 P)e Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com August 13, 2015 Re: McManus Window/Door Installation 10600 S Ocean Dr. (#1006) Jensen Beach,FL. 34957 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of window and door replacement at the above referenced address. Wind speed: Vuit: 165 mph, V,,d: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Location: Covered Porch(See Attached Sketch) Required Design Pressure: Doors +43.7/-47.5 psif Window +43.7/-47.5psf Products to be installed shall be equal to,or exceed the required design pressures as listed above "Required Design Pressure". Products shall be installed in accordance with the manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Doors shall be FL# 16133.2 Window shall be NOA# 12-0306.02 Thank you for your attention to this matter. PAUL, L•-CH �_CP-,.v- PauVwelc Reg.No 29945 McMANUS RESIDENCE FLOOR PLAN 10600 S. OCEAN DRIVE - #1006 S�'©I C� thlAS�$'DOOR M AM IM � D®©R UV ENDO OPENING SCHEDULE y a i ✓ r r.. #1-910" X 8'0" SG #2- 12'0" X8'0" SGD ' tia #3-#35 SH PAULJWELCH'INC•r?'-yi'I M ECH-ELECT=.CI VIL ENG: 1984 BILTMORE,ST.'',#1;;14 " i PORT SAINT LUCIE;"FL 34984 PAUL WELCH P.E. FLA REG NO.29945