Loading...
HomeMy WebLinkAboutProduct Approval MIAMI•DADE MIAMI-DADE COUNTY ffe M1 PRODUCT CONTROL SECTION r' 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECt?4O (RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSIO T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE NOA www.miamidade.¢ov/economy DAB Door Company,Inc. 12195 NW 98"Avenue ! . Hialeah Gardens,FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Hurricane Master®Model 824/811 Steel Sectional Garage Door 16'-2"Wide with Window Lite Option(DP+36.0,44.0 PSF) APPROVAL DOCUMENT:Drawing No.02-21,titled"24 GA.Roll Formed Steel Sectional Garage Door",dated 09/10/2002,with last revision K dated 03/09/2015,sheets 1 through 5 of 5,prepared by Al- Farooq Corporation,signed and sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING:A permanent label with the manufacturer's name or logo,manufacturing address,model/series number,the positive and negative design pressure rating,indicate impact rated if applicable,installation instruction drawing reference number, approval number(NOA),the applicable test standards,and the statement reading`Miami-Dade County Product Control Approved' is to be located on the door's side track, bottom angle,or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#14-0814.10 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.15-0304.01 MIAMI•DADECOUNTY Expiration Date:July 21,2020 1S Approval Date:April 23,2015 to Page 1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.02-21,titled"24 GA.Roll Formed Steel Sectional Garage Door",dated 09/10/2002,with last revision J dated 11/07/2014,sheets 1 through 5 of 5,prepared by Al- Farooq Corporation,signed and sealed by Javad Ahmad,P.E. B. TESTS `Submitted under NOA#11-0414.12" 1. Test Report on Uniform Static Air Pressure Test,Loading and Forced Entry Test per FBC, TAS 202-94,of"DAB 824 Sectional Residential Garage Door"prepared by Hurricane Engineering&Testing Inc.,Report No.HETI-07-4200,dated 05/02/2007,signed and sealed by Candido F.Font,P.E. 2. Test Report on Large Missile Impact Test per FBC,TAS 201-94 and Cyclic Wind Pressure Test per FBC,TAS 203-94,of"DAB 824 Sectional Residential Garage Door",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI-11-3204,dated 01/20/2011,signed and sealed by Candido F.Font,P.E. 3. Test Report on Tensile Test per ASTM E8-08 of"Sectional Residential Door(skin)", prepared by Hurricane Engineering&Testing Inc,Report No.HETI-11-T100,dated 01/21/2011,signed and sealed by Candido F.Font,P.E. "Submitted under NOA#05-0228.02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test,of"Sectional Residential Door with Windows",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 03-1328,dated 07/15/2003,signed and sealed by Rafael E.Droz-Seda,P.E. S. Test Report on Uniform Static Air Pressure Test,of"Sectional Residential Door"prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 03-1329,dated 07/15/2003,signed and sealed by Rafael E.Droz-Seda,P.E. 6. Test Report on Tensile Test per ASTM E-8 of"Sectional Residential Door(skin)",prepared by Hurricane Engineering&Testing Inc,Report No.HETI 03-T078,dated 10/31/2003, signed and sealed by Rafael E.Droz-Seda,P.E. "Submitted under NOA#03-0210.04" 7. Test report on Salt Spray(Corrosion)Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation,Test Report NQ.258592,dated 08/17/1998,signed by W.A. Jackson,P.E. C. CALCULATIONS "Submitted under NOA#14-0814.10" 1. Anchor verification calculations prepared by Al-Farooq Corporation,dated 09/22/2014 and 07/24/2014,signed and sealed by Javad Ahmad,P.E. o41G��S Carlos M.Utrera,P.E. Product Control Examiner NOA No.15-0304.01 Expiration Date:July 21,2020 Approval Date:April 23,2015 E-1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS(Cont.) "Submitted under NOA#11-0414.12" 2. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007,dated 04/07/2011,signed and sealed by Javad Ahmad,P.E. 3. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007,dated 12/19/2008,signed and sealed by Humayoun Farooq,P.E. "Submitted under NOA#09-0128.02" D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.13-0717.01, issued to SABIC Innovative Plastics,for their Lexan Sheet Products,approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08,issued to Insulfoam,LLC,for their Insulfoam Expanded Polystyrene Insulation,approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07,issued to Dyplast Products,LLC,for their Expanded Polystyrene Block Type Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No.11-0926.06,issued to Dyplast Products,LLC,for their Dyplast ISO-C1 Polyisocyanurate Insulation,approved on 11/10/2011 and expiring on 01/11/2017. S. Notice of Acceptance No. 10-1129.04,issued to Cellofoam North America Inc,for their Expanded Polystyrene Block Insulation,approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA#05-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of"PVC Extrusion Material",prepared by Hurricane Engineering& Testing,Inc.,Report No.HETI 04-A002,dated 09/27/2004,signed and sealed by Rafael E. Droz-Seda,P.E. 7. Test Reports on Tensile Test per ASTM D638 of"PVC Extrusion Material",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 04-T251,dated 11/29/2004 signed and sealed by I. Ghia,P.E. 8. Test Report on Self-Ignition Temperature Test,Rate of Burn Test and Smoke Density Test of"REHAU non-foam PVC extrusion material",prepared by ETC Laboratories, Report No.04-761-15019.0,dated 05/06/2004,signed and sealed by J.L.Doldan,P.E. F. STATEMENTS "Submitted under NOA#14-0814.10" 1. Statement letter of code conformance to the 511 edition(2014)FBC and no financial interest issued by Al-Farooq Corporation,dated 05/13/2014,signed and sealed by Javad Ahmad,P.E. � iLhp)S Carlos M.Utrera,P.E. Product Control Examiner NOA No.15-0304.01 Expiration Date:July 21,2020 Approval Date:April 23,2015 E-2 7-1/2"X 2-1/4"X 18 GA. --- PUSH NUT TOP FIXTURE 5-1/2"X 2-3/4'X 0.1" GALV. STEEL CENTER HINGE ' STEEL PLATE WITH ONE 5/16-18 MS W/NUT OPTIONAL DOOR VIEWER Q W/(4)014 X 5/8"SMS / `♦♦ -FASTENED TO ENO STILE WITH TO BE INSTALLED AT 1!6 N WITHOUT DELRON SLEEVE(SID.) (6) 014 X 3/4"SELF DRILLING SCREWS ANY CENTER STILE 4Y 1 O 7-1/2"X 3"X .071'GALV.STEEL E O 0 t SEE SHEET 3 FOR TOP BRACKET OPTIONS o END ROLLER HINGE I I Z W/(6)014 X 5/8"SMS t O O r CENTER STILES r A Q WITHOUT DELRON SLEEVE(STD.) / SEE n O WITH DELRON SLEEVE(OPTIONAL) L♦`p /2"X 2-1 4'X •071" LOCK ♦♦ ``-` III III JII�II III jIIf . STEEL ER NINGE IFCI O (4)014 X 5/8'SMS _2/DOOR W ♦ I O WITH DELRON SLEEVE(OPT)ONALf_:� _�`` `♦ i"W X.15 THK. LATCH♦♦ � t - I. - - a CENTER_HINGE 11♦ STANDARD LOCK ♦ S I rc rc g1 n 2 ♦ SPRING LOADED SLIDE BOLT(BOTH SID�Si W FASTENED W/(4) 014 X 1/2"S.M.S. ♦ _/1 I r o Q 3 ., ti �_____5/8"MIN.LOCH ENGAGEMENT ♦♦ [` - -_ ""-- —�-- __ � -. _ 1 =o �$ w�:°� . CONFORMS TO SECTION 1008 REGARDING 1 J -— - _ - _ _ 3 N$C1 GARAGE DOORS -- -- Z ¢Z Q y 5 -_ f tt �I ,• Dw ow .158 DIA.CALV.AIRCRAFT TYPE O o s g 0 WACABLE&NIGO-PRESS SLEEVE `�♦ p `♦♦♦ B - ,1 _ B i b. IN. 5 TO 1 SAFETY FACTOR r, ♦♦ r ` r —.-_.__._'_ -- 1tzo .n 2-3/4"W X 5-5/8"H X.090'THK.' STEEL PLATE, 1-3/8"DE,P i t i -- -_- - _•-= 6"'�" _ - — — _ WITH (3)014 X 3/4" ♦U tO ♦♦ O ' -- ---. .] o n SELF DRIVING SCREWS xI IZviBRACKET BRACKETSTD. LIFT DOOR LOW HEADROOMTOTAL g OF DOOR OPTION r _ _ - - - -- U v e DOOR 'U'BMS AT El N co HEIGHT CONSISTS OF EACH DOOR 7-7/8'X 3-1/8"X.010' r OPTIONAL VENTS I e 6'-6' T SECTIONS I8'2 SECTIONS 2j' STEEL PLATE AT 7"O.C. MAX. OPTIONAL FLUSH FACE O� % A (3) 5"WIDE 6'-9• f SECTION te' 3 SECTIONS 21' WITH (4)014 X 3/4'SOS OPNG.ARFA NOT TO EXCEED 120 SO.IN. MAX. DOOR WIDTH -WOOD GRAIN DESIGN L p p .CO N Z x - 7' 4 SECTIONS 21'- ______ 16'-2" ....— .. v"1 7'-6" 5 SECTIONS 18"- CENTER STILE DAB DOORS INC. e3 INSIDE ELEVATION ¢a 7'-9' 4 SECTIONS 18'1 SECTION 21' Hurricane Master®Model 824/811 r D x OUTSIDE RAISED PANEL EMBOSSED DOOR e' 3 SECTIONS 18'2 SECTIONS 21" HANDLE ENp STILE MOX. SiNa w ute X ion High O 8'-J' 2 SECTIONS 18'3 SECTIONS 21" With Window Lite Option W S" 1 SECTION 18" 4 SECTIONS 21• 014 X 3/4"SELF DRIVING SCREWS MAY BE USED W-9" 5 SECTIONS 21'- IN LIEU OF 014 X 5/8"SMS 9' a SECTIONS 18•- LocK BAR cu1DEs -/8-SMS DESIGN PRESSURE RATING = + 36.0 PSP W-3' 5 SECTIONS 18'1 SECTION 21' INSTALLED ON END STILE - 44.0 PSF V' 6' 4 SECTIONS 18'2 SECTIONS 21' WITH (4) 014 X 5/8"sMS THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT GENERAL NOTES gg 9'-9' 3 SECTIONS 18'3 SECTIONS 21' 4 c 2 p€€€ 10' 2 SECTIONS ia'4 SECTIONS 21' 18T X .6W LOCK BAR I. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE 2 o rruu 10'-3• 1 SECTION is, 5 SECTIONS 21' ENGAGES IN TRACK REQUIREMENTS OF THE FLORIDA BUILOI G CODE(FBC)FIFTH EDITION(2014) 22SS ON EACH SIDE OF DOOR INCLUDING HIGH VELOCITY HURRICANE ZONE MMZ u f0'-6'6 SECTIONS 21'- CENTER SALES SCHEDULE'A' ( )• �+ 10'-9"6 SECTIONS 18'1 SECTION 21" OUTSIDE KEYED LOCK 2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. 11' S SECTIONS 18"2 SECTIONS 2t' CENTER STILES CONFIGURATION ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL 11'-3' 4 SECTIONS 16"3 SECTIONS 21' OPTIONAL ® ®® ® DOOR VADTHS 0 Oi CENTER STILES DRESSING OR STUCCO. - IV-8' 3 SECTIONS 18'4 SECTIONS 21' LOCK BAR LOCKING SHOWN W-0"TO V-10' 2 3. ALL BOLTS,NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL 11'-9'2 SECTIONS 1a'S SECTIONS 21' ALTERNATE TO 10'-0'TO I1'-10" _ _2 _ 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN 0 12' 1 SECTIONS 18'5 SECTIONS 21• SPRING LOADED SLIDE BOLT 12'-0"TO 13'-10' 3 o n 9 THESE DETAILS ARE NOT PART OF THIS APPROVAL. 'i o S=o 12'-3' 7 SECTIONS 21'- LOCKS SHOWN ABOVE I W-O"TO 9'-1O" 14'-0•TO 15'-10' 4 'S 12'-6" 6 SECTIONS 18'2 SECTIONS 21" I^ 15'-1f•TO 18'-2' S 5. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. i_ x DOOR WIDTHS 12'-9' 6 SECTIONS 18'J SECTIONS 21' DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA 0 13' 4 SECTIONS 18'4 SECTIONS 21' BUILDING CODE,TAS-202,TAS-201 &TAS-203 FOR HVHZ AND 1J'-J' 3 SECTIONS 18"S SECTIONS 21" ASTM EI886-O5/ASTM E1996-09. N Y ® ® ® In 0 g 13'-8' 2 SECTIONS 18'8 SECTIONS Ti' En9r.JAVAD AHMAD a IS-S" 1 SECTION 18• 7 SECTIONS 21' CML lROWLTfIGI4EWFD n 14' 8 SECTIONS 21'- IP I FU.PE 3B 10'-0'TO 11'-10" 14'-0'TO 15'-10` CA.N. 3B 8 SECTIONS 18'3 SECTIONS 21' IV-6' 5 SECTIONS 18'4 SECTIONS 21' DOOR WIDTHS DOOR WIDTHS � 1 IS- 4 SECTIONS 18 5 SECTIONS 21' ® r� ® ® ®® ® T— I 15' 3 SECTIONS 18'6 SECTIONS 21' IO7 All By dm__ g n0. 15'-3' 2 SECTIONS 18'7 SECTIONS 21' 4V2015 15'-6' 1 SECTION 18' a SECTIONS 21" n 11 n IT02-21 I5'-9" 9 SECTIONS 21'- �12'-0'TO 13'-10'_� ��15'-11"TO 16'-2" 16' 6 SECTIONS 18'4 SECTIONS 21" DOOR WIDTHS DOOR WIDTHS sheet 1 of 5 24 GA.STEEL PANEL- _ O ® FLAPS BENT OVER PANEL-\ Q N O O �aQSI � - - r GI o 1/2"PUNCHED HOLES I C 0 4"O.C. o, 1 O pelf cy Irl p 4c oss'x z-1/4•x J/a'x z• 04�& GAILY.STEEL U.BAR REINFORCING TRUSS - I C� G A BOTTOM OF PANEL TRUSS FASTENED TO 1 a W o VERTICAL INTERMEDIATE STILES W/TWO I Qt4 x 5/8'S.M.S.AND TO END STILE - 1 z gg W/FOUR(114 X 3/4"SELF ORILUNG S. Ip Q 10 1 1 - - - ®O Z uWi v l s o 3/16"POP RIVETS TEND AT 4"O.C.6)FOR 21"STILES 9 .(5) FOR 18"STILES .024'STL PANELTILE y ¢J OUTSIDE OF DOOR C3 W Z F Z 6 _mW N am o I IST SECTION (BOTTOM) INTERMEDIATE SECTION TOP SECTION 6c 0 z 0 w & �01 OPTIONAL STOP MOULDING BY DOOR INSTALLER SOLID BRASS DOOR VIEWER r x STEEL TRACK BRACKET FASTENED BY 'SCHIAGE SECURITY HARDWARE' TO WOOD JAMB WITH S 14 x 5/8'SMS 3/4"X 2'x 2-1/2"x .049'STEEL INSTALLED IN 9/16" DIA HOLES IN CENTER STILE 5/16'X 1-5/8"LAG SCREW 6 PER HINGE END STILE,CONNECT TO PANELS WITH (FULLY THREADFLAPS AND(5)OR(6)3/16"ALUM RIVETS POSITIONED AT EYE LEVEL ED) HEX WASHER HEAD TYPE A 1/2"% 1-3/4'%.058'FORKED STEEL SEE DETAIL ABOVE G ONE PER BRACKET CLUED TO PANEL AND SECURED TO ANCHORS AT TRACK BRACKET• END STILE WITH (4)3/16'POP RIVETSEDGE ---���111 3a*DLA.POWER-BOLT BY'POWERS' h b SOUTHERN PINE ,%a�• 1-7/8'X 2-5/8"X.049'STEEL DISTANCE A) 2'MIN.EMBED INTO CONCRETE(3000 PSI MIN.) o 0.55 S, � CENTER STILE,GLUED AND RIVETED 2"MIN.EDGE DISTANCE TO PANEL W/(4)3/18"RIVETS A' 1- MIN. POP 16 RIVETS ° v11-3/18 ,.)/8'Ole c EEVc BY'HILT? w Q 14 X 5/8'S.M.S. 1 DIST• I 4/HINGE 1 \ ° `�.° '1y B) 1-1/4"MIN, EMBED INTO CONCRETE OR FILLED BLOCK .29.2 2 2 f 2-1/4"MIN.EDGE DISTANCE INTO CONCRETE F 1 I 1 4' MIN.EDGE DISTANCE INTO FILLED BLOCK i 1-3/18• CONCRETE 1'c -3000 PSI MIN. o c 2 H;4 e C-90 GROUT FILLED BLOCK I'm 2000 PSI MIN. A a B 8 1.9'X2.19'% 3.3'% 090' ANCHOR TYPE A ORB 0ux_,x STEEL TRACK BRACKETS I I I i r (I)PER BRACKET o SEE SHEET J FOR SPACING E SHEEP 3 FOR BRACKET SPACING Engr:JAVAD AHMAD PUIDDUCrItENEMM 1 I FIA PES 70594 o00r116161MMI�NFW1Ws Yi 1 CTp� b 7-(0"X .050" 7-1/2"% .071' 1/4-20 SS BOLT CA.N. 38 �� b , LV.STEEL INTERIOR SIDE END ROLLER HINGE & Ntn � $ STEEL TRACK CENTER HINGE 14 CA. X 2-1/8'X 1'(STANDARD) 1.82•DIA% .60"STEEL ROLLERS(STD.)) 0 015 A drawing njo I2 GA.X 3-5/16'X 1-1/2•(OPTIONAL) 7/B'PUSHNUT 1.82"DIA. X .50"NYLON ROLLERS(OPTIONAL3 , FASTENED TO 8"TR PLATES INSTALLED ON ROLLER SHAFT 2.75'DIA. X.50"STEEL ROLLERS((OPTIONAL— C_4 W/1/4-20 X 5/8'TRUSS NO. 2.75"OIA. X .50"NYLON ROLLERS(OPTIONAL) SLOTTED M.S. k LOCK NUT SECTION B-B WITH 5'STEM sheat 2-f 1-1/2"X 1/2"X 1/8"HORIZ.ANGLE m ° /POP RIVETS5/16"% 1-5/B"LAG SCREWS INTO WOOD OR HORIZ.TRACK SUPPORT, FOR DOOR HEIGHTS UPTO 8 FT. �u o I I/ 2-3/4'X 5-1/2"X 3"X.104° - - 5/16•SLEEVE ANCHORS CENTER SUPPORT REOD. ON DOORS WITHOUT INSULATION OR WINDOWS, N I2 �W.STEEL WITH 1-1/4'EMBED INTO MASONRY EXREEDING B FT.IN HEIGHT 2"X 2-X 1/8"HORIZ.ANGLE I OP ROLLER BRACKET ON EACH SIDE 3 PER BRACKET II A FOR DOOR HEIGHTS ABOVE B FT.OR o FASTENED W/(6)Y 14 X 5/6'S.M.S. II 1 DOORS WITH INSULATION OR WINDOWS Z SPOT WELDED TO HORZ,TRACK O 14 GA.GALV.STEEL ADJUSTABLE WITH TWO WELDS AT 1-1/2'APART 2-1/2'X 4-1/4'X 13 GA STEEL PLATES A J FIRST AT 3"O.C.,REST AT SLIDE FASTENED TO BRACKET WELDED TO 1-1/2"X 1-1/2`X 14 GA ANGLE -- N� M. CREWS B%J/4•HEX HEAD - CONNECTED TO FIA/BPACKET ANGLE M.SCREWS&NUTS. FASTENED TO TRACK - -- W/3/8-16%3/4'BOLT&NUf O WITH (4) 1/4-20 SS. BOLT&NUTS -- HORIZ.TRACK LENGTH- OPENING HEIGHT PLUS 12° AND TO SPRING SHAFT GUIDE WITH TOP BRACKET - - (2) 1/4-20 X 5/8'BOLT&NUT °(STANDARD) TOP BRACKET) c( �Q 4 LOW HEAORbOMnDOD _ v 14 GA.GALV.STEEL TRACK G HORIZONTAL REINFORCEMENT a�wa Q 1/2"X 1-3/4"X.058'FORMED STEEL VERTICAL TRACK Q'1 Q O GLUED TO PANEL AND FASTENED TO 2-1/8•%1'%.OBD' 0 ea m VERTICAL STILES WITH Y X 5-1/2•x too' SECTION A—A (2)3/18'POP RIVETS (( GALV.STEEL FASTENED W[OP4 RJLLER BRACKET FOR .1 S. a HORIZONTAL REINFORCEMENT LOW HEADROOM DOOR OPTION DOOR • SECTION HEIGHTS BRACKET PLACEMENTS a F 1/2°X 1-3/4°X.058'FORMED STEEL HEIGHT IST 2ND 3RD 4TH 5TH 81 82 B3 B4 B5 86 87 BH GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH - 6'-0' 18" 18' 18" 18"N/A 1"TO 2"I1-3/4" 23" 34` 45° 56" 67" a (2)3/16'POP RIVETS 6'-6" 21' 18' 18"21'N/A 1°TO 2'11-3/4" 23" 34' 45" 56" 67" 5/16'MEETING RIB 7'-0" 21'21" 21°21°N/A 1°TO 2'11-3/4" 23' 34° 45' S6" 67" - _ PLASTIC/STEEL ROLLERS 7'-6' 18"18° iB" 18" 18"1"TO 2'I1-3/4" 23• 34 45" 56" 67" 7B-i/4" ®. PLASTIC/STEEL DIA. X.50" _ 8'-0' 21" 18' 18" 1B' 21"1°TO 2"11-3/4" 23° N. 45" 56 67" 78-1/4' 1.82"�W/.44 DIA X 4-1/4'STEM M w —SECTIONS ARE NUMBERED STARTING AT THE BOTTOM M ®. x FOR DOORS MORE THAN 8 FT.HIGH, USE ADDITIONAL TRACK BRACKETS AT 10"O.C. OPTIONAL INSULATIONS: z m Q BY'DYPLAST PRODUCTS LLC' 3o EPS EXPANDED POLYSTYRENE 'o m 1.9'X 2.19°%3.3'%.090' m USN DENSITY a 1.05 PCF o / Z e N.OA®11-0926.07 STEEL TRACK BRACKETS W u OR n 2-3/18'HIGH B OI p I ISO-25 PDLY-ISOCYANURATE m CONNECTED TO TRACK WITH K DENSITY-2.0 PCF ) 1/4"BOLTS&NUTS. O Z p N - ----N.OA.®11-0926.06 m _.� / o BY'CELLOFOAM NORTH AMERICA' � rn�... DENSITY- 1.03 PCF N OR d10-1129.04 BY'INSULFOAM LLC' C' DENSITY-0.92 PCF '� O N.OA #14-0311.08 m / 0 14 GA GALY.STEEL ROLLER HINGES FASTENED m W/(6)1114 X 5/8'SMS MIN. 024'ROLL FORMED STEEL PANEL m 8 y€; DRAWING DUALITY G-40 C 3$ MIN.YIELD STRENGTH-39 KSI 3 -- "'WITH PRMER AND BAKED-ON at= g POLYSTER PAINTED TOP COAT TRACK CONFIGURATION APPLIED TO BOTH SIDES OF STEEL d a rn - oo:l�d6� N VERTICAL LIFT HIGH L{FT STANDARD LIFT LOW HEADROOM S a � DOUBLE TRACK r� 12 GA.GALV.STEEL BOTTOM BRACKET FASTENED X11 AAI F.TRACK OPTIONS o J W/(4) B 14 X 5/8'SMS EAgr.JAVAD ANMAD b CIVIL ]PRODUCT RENEWED FLAPE 70592 w�L w11b1YPIoliO� I O' BOTTOM SEAL OPTIONS CA.N. 3B SEE SHEET 5 R � tAroalaC� drawing n0. SECTION A-A 02-21 SEE SHEET 2 FOR LOCATION OF REINFORCING TRUSSES sheet 3oL 5 REINFORCEMENT �f 'IN. 4W-:TR 'X 1-3/4'X.058" ED STEEL EEL i 1-1/2'MIN. DISI. SELF DRILLING SCREWS �— X 1" Z LF DRILLING SCREWS I GE DIST. I m 3/16''RIVEIC'STEEL RIVETS 1. iv n MULTIGRIP W/DOME HEAD 16"'RNEW STEEL RIVETS Q Z AT 48'O.C. LTIGRIP W/DOME HEAD F'" La 1 i \ 48'O.C. a r REINFORCEMENT S 1/2'X 1-3/4'X.058' Q 2BY 1/4'DIA.UG SCREWS 28Y 1/4'DIA.LAG SCREWS FORMED STEEL OLWOOD BU 1 AT 6"FROM ENDS WOOD SU I AT 6°FROM ENDS AND 15'O.C.MNG. ; AND 15'O.C.MAX. pW STRIPMINUM ADAPTER OCQL RUBBER W'STRIPPING R W'STRIPPING ,040 I Ip .22�4 6.3 LS 1J. 4 700 348 0 BOTTOM SEAL OPTIONS 4�4� OPTION 'A' OPTION 'B' c`5 WOOD BUCK CONNECTION TO WOOD SUBSTRATE(WOOD SPECIFIC GRAVITY SG-0.55 MIN.) n n THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN Q LL WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE _. Z uj r VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. _ ANCHOR SPACING 03 W '$ ANCHORS STRUCTURE _EMBED SPACING EDGE 01ST. 8 N OIin 1 318-HLC SLEEVE BY HILTI CONC. 1-1/4'1 B' 2" d. J 8 CONFLIX BY'ELCO FILLED BLOCK3-3 4' B'DYNABOLT BY 11 GONG. 1-1" N 3 2 B' 2-1 2 -1 O Z STEEL STRUCTURE BY OTHERS 3 8 POWER-BOLT BY POWERS CONC. 8' 2' o 0 5/16'X 1-5/8" MUST SUPPORT THE LOADS IMPOSED 3 8 SLEEVE-ALl BY SIMPSONS CONC. 1-1.2 _ 8' 3_, O'nj Ii UC SCR�ws 8Y DOOR SYSTEM Q N g AT 12' CONCRETE f'c=3000 PSI MIN. C-90 GROUT FILLED BLOCK MmZPSI N '-"_ 5/16"DIA BOLTS . WITH WASHER&NUT WOOD BUCK CONNECTION TO MASONRY �. .'_• �AT 12"D.C.MAX. EDGE DIST. PRESSURE TREATED 2X8 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 6 G <1 ROUTED REINFORCED MASONRY BLOCK WALL OR CONC.COLUMN WITH j g 1/4 ULTRACON BY ELCO WITH SPACING OF 12"O.C.INTO GROUT FILLED BLOCK WALL,WITH 2-1 4"MIN. EMBED 13'O.C.INTO 3000 PSI CONCRETE,WITH 1-3/4'MIN.EMBED 1-1/4'%2-1 2"% 14 CA _ I o pg5 2-1/2"MIN, EDGE DISTANCE 1 1-1/2" 1-1/2° CONT.STEEL ANGLE 11-1/2 B B 1/4"TAPPER BY'POWERS'WITH SPACING OF 12 GA GAIN.STEEL H 11"O.C.INTO GROUT FILLED BLOCK WALL,WITH 1-1/2'MIN. EMBED —PUT BRACKETS t3'LONG 2_1 g % 1'X 14 OA. 01 13'O.C.INTO 3000 PSI CONCRETE,WITH 1-3/4'MIH,EMBED 1/16'%2-1/2 AT 12"O.C. IN DOOR OF G. GAL STEEL TRACK 3"MIN. EDGE DISTANCE FILLET WELDS AT 18"O.C.ABOVE ODOR DPNG. FASTENED TO TRACK PLATES 3/8'CONFLEX BY'ELCO'OR AT 12"O.C.MAX. CONNECTED TO CONT.ANGLE W/(2)1/4-2OX5/8'TRUSS HD. m 3/8'LOT BY'ITV WITH SPACING OF W/(3)SPOT WELDS AT EACH SIDE SLOTTED 1.S.&LOCK NUr C S v m 23°O.C,INTO 3000 PSI CONCRETE,WITH 2-1/2'MIN.EMBED °e^; N.MIN.EDGE DISTANCE CONTINUOUS ANGLE TRACK REVERSE TRACK CONTINUOUS ANGLE TRACK 'm d^n 15 3/B'HLC SLEEVE BY'HILTI'WITH SPACING OF TO WOOD RUCK TO STEEL TO CONCRETE ANO FII l FO BLOCK c 10'O.C.INTO GROUT FILLED BLOCK WALL,WITH 1-1 4'MIN.EMBED,4"MIN. EDGE DIST, C--� 15'O.C.INTO 3000 PSI CONCRETE,WITH 1-1/4'MIN.EMBED AND 2-1/2"MIN.EDGE DISTANCE ALTERNATE TRACK INSTALLATION PREPARATION OF JAMBS BY OTHERS � J�CML 70592 P PRODUCT RENEWPD FLA. lj4�g4.p.4udXr FloTiO� d I FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY CAN.'S538 DJIdIy Q7i1 ' ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED Aft mNo B/ 1t BY DOOR SYSTEM. a7JA v $ J$ FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD,DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY Browing no. BURRING OFFICIAL UPON INSPECTION. Z0�5 A�Orol CoYd MAXIMUM EXTERIOR(+)LOAD PER JAMB (16.16'X 62 PSF)/2 291 Lbs per Ft. OZ-Z 1 MAXIMUM INTERIOR(-)LOAD PER JAMB (16.16' X 44 PSF)/2 0 355.5 Lba per Ft. sheet 4of 5 ' .5G0 f�-a•F-.256 U *PLASTIC COMPLIES WITH I w CHAPTER 26 OF FBC ev DOOR PANEL SEE EVIDENCE PAGE 24 GA(.024)STEEL MIN, d 1.765 7/16'DIA.WASHER 1.144 p �I V r I V p r1 p8% 3/4-SMS 21 3/4" o FROM ENDS MAX. .176 .000 a Q D.C. ® 11 .Iii t1 nND 7" .C.MAX. wDw.WIDTH *EXTERIOR FRAME * j�ERIOR FRAME 0D c _ a 18 1/8" RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION Q w m 3 "G 1111 (4)BB X 3/4'SMS w = o MAX. LL y t 1 i i l t 0 1-3/8-FROM ENDS r; a O.L.O. AND 6-1/2.O.C.MAX. a g iO -- _ R W.�f I I I O L iii _ E51E] '' � oil w 1111 175 X .062 DEEP 11 i I 0 GROOVE 1/4-POLYCAROGNATElE7NN 0Y'SAOIC INNOVATIVE PLASTICS'A @13-0717.01a III! .. .. :iujfa 4o 3i= owIppzrnr� u -- I'i l 175 X.062 DEEP 1111 GROOVE _ o 111 P. (4)g8 X 3/4-SMS INSIDE ELEVATION O 1-3/8'FROM ENDS RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS AND 6-t/2'D.C.W. WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION d8 X 3/4'SMS i C 175 X.062 DEEP c S ®3/8'FROM ENDS 0 d g j t j i AND 4-1/2'O.C.MAX. GROOVE •o o q g8 X 3/4'SMS ®3/8'FROM ENDS 1.-t - nq AND 7'O.C.MAX. --' I?IxQpUC!'REt!tKV1Ft► d o CPAL 7/16-GAA WASHER `v - __J_ _ _ _ _ _ _ _ F CAN.LA.PE 538 2 DOOR PANEL EXTERIOR pp 11ulYRCt11 dr4w1�-� 24 CAL(.024)STEEL MIN. 15/16'MIN. D.L.OPG. i �J - ^ g rano. 240R PANEL GA.(.024)STEEL MIN. GLAZING 817E 02-21 WINDOW WIDTH sheet$Qf $ t M1AMPDADE MIAMI-RADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www.mlamldade.eov/economy DAB Door Company,Inc. , 12195 NW 9811 Avenue Hialeah Gardens,FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the usiof co n materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Pr " ct C trol Section to be used in Miami Dade County and other areas where allowed by the Authority Having Junsdi (A This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Pro on I Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right ave i duct or material tested for quality assurance purposes. If this product or material fails to perform in the a er, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or sut a use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is d ed by Miami-Dade County Product Control Section that this product or material fails to meet the requirem" s of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Hurricane Master Model 824/811 Steel Sectional Garage Door up to 9'-4"Wide w/ Window Lite Option(DP+50.0,-60.0 PSF) APPROVAL DOCUMENT:Drawing No.01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5, dated 02/01/2001,with last revision J dated 03/09/2015,prepared by Al-Farooq Corporation,signed and sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING:A permanent label with the manufacturer's name or logo,manufacturing address,model number,the positive and negative design pressure rating,indicate impact rated if applicable,installation instruction drawing reference number,approval number(NOA),the applicable test standards,and the statement reading`Miami-Dade County Product Control Approved' is to be located on the door's side hack, bottom angle,or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION.of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#14-0814.04 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.15-0317.02 C •DADEcouNTY Expiration Date:August 9,2016 • Approval Date:June 11,2015 ms Page 1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5,dated 02/01/2001,with last revision J dated 03/09/2015;prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. B. TESTS "Submitted under NOA#09-0128.04" 1. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 4)Forced Entry Test,per FBC 24113.2.1,TAS 202-94 i along with marked-up drawings and installation diagram of a DAB 824 24 GA Sectional Garage Door with Fixed Windows,prepared by Hurricane Engineering& Testing,Inc,Test Reports No.HETI-08-2149A/B,dated 06/27/2008,signed and sealed by Candido F.Font,P.E. "Submitted under NOA#09-0128.04" 2. Test report of Tensile Test per ASTM E 8,Report No.HETI 08-T182,prepared by Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by Candido F.Pont,P.E. "Submitted under NOA #01-0516.03" 3. Test report of large missile impact test per PA 201 and cyclic wind pressure test per PA 203 on"Sectional Residential Garage Door",prepared by Hurricane Engineering &Testing,Inc.,Report No. HETI 01-974A,dated 01/29/2001,signed and sealed by Hector M.Medina,P.E. 4. Test report of Uniform Static Air Pressure Test per PA 202 and Force Entry Resistance Test on"Sectional Residential Garage Door",prepared by Hurricane Engineering&Testing,Inc.,Report No.HETI 01-969,dated 01/18/2001,signed and sealed by Hector M.Medina,P.E. 5. Test report on Salt Spray(Corrosion)Test per ASTM B 117 of a painted G-40 steel panels,prepared by Celotex Corporation,Test Report No.258592, dated 08/17/1998, signed by W.A.Jackson,P.E. o�Jo2��•is Carlos M.Utrera,P.E. Product Control Examiner NOA No.15-0317.02 Expiration Date:August 9,2016 Approval Date:June 11,2015 E-1 DAB Door Comnanv,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS "Submitted under NOA#14-0814.04" 1. Anchor verification calculations prepared by Al-Farooq Corporation,dated 09/22/2014 and 07/24/2014,signed and sealed by Javad Ahmad,P.E. "Submitted under NOA#09-0128.04" 2. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007,dated 12/19/2008,signed and sealed by Humayoun Farooq,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0717.01,issued to SABIC Innovative Plastics,for their Lexan Sheet Products,approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08,issued to Insulfoam,LLC,for their Insulfoam Expanded Polystyrene Insulation,approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. I1-0926.07,issued to Dyplast Products,LLC,for their Expanded Polystyrene Block Type Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06,issued to Dyplast Products,LLC,for their Dyplast ISO-C1 Polyisocyanurate Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 10-1129.04,issued to Cellofoam North America Inc,for their Expanded Polystyrene Block Insulation,approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA#OS-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per ASTM G155 of"PVC Extrusion Material",prepared by Hurricane Engineering& Testing,Inc.,Report No.HETI 04-A002,dated 09/27/2004,signed and sealed by Rafael E. Droz-Seda,P.E. 7. Test Reports on Tensile Test per ASTM D638 of"PVC Extrusion Material',prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 04-T251,dated 11/29/2004 signed and sealed by I.Ghia,Pte. 8. Test Report on Self-Ignition Temperature Test,Rate of Burn Test and Smoke Density Test of"REHAU non-foam PVC extnision material',prepared by ETC Laboratories, Report No. 04-761-15019.0,dated 05/06/2004,signed and sealed by J.L.Doldan,P.E. F. STATEMENTS "Submitted under NOA#14-0814.04" 1. Statement letter of code conformance to the 5"edition(2014)FBC and of no financial interest issued by Al-Farooq Corporation,dated 05/13/2014,signed and sealed by Javad Ahmad,P.E. . � a2 Zots Carlos M, trera,P.E. Product Control Examiner NOA No. 15-0317.02 Expiration Date:August 9,2016 Approval Date:June 11,2015 E-2 7-1/2'X 3"X,071"GALV.STEEL TOP FI)CTURE 5-1/2'X 2-3/4'X 0.1" Y o END ROLLER HINGE _-_ STEEL PLATE WITH ONE 5/16-18 MS W/NUT m W/(6) 914 X 5/8'SMS FASTENED TO END STILE WITH OPTIONAL DOOR VIEWER WITHOUT DELRON SLEEVE (STD.) �'� (6) 914 X 3/4'SELF DRILLING SCREWS TO BE INSTALLED AT o WITH DELRON SLEEVE(OPTIONAL) v ``�� CENTER STILE T. CENTER STILE C 1 e 1 T Q'&gym 7-1/2' X 2-1/4'%.071" 1 ---- - !_0 Cp o 1 e CALV.STEEL CENTER HINGE - �� '. a0� 1 W/ (4) 914 X 5/8°SMS _.— -- -- - ¢ o: 9 r WITH DELRON SLEEVE(OPTIONAL) B 1� o $ LL=N---S \` LOCK 2/DOOR ' %0 o ' t '01 Z 1"W X .15°THK. LATCH0ARD LOCK o r - —= I 00 LOADED SLIDE BOLT(BOTH SIDES) =�r6'� - - = O FASTENED W/(4)914 X 1/2"S.M.S. — - —� - O -- 5/8"MIN.LOCK ENGAGEMENT ''L V a~ V I O LLj 1'1 CONFORMS TO SECTION 1008 REGARDING GARAGI`DOORS II1I 1111 IIf�_I''(IIII Q, - O`1 1 � _ �OPTIONAL mDOOR HOW CONSISTS OF I `6'-6' 2 SECTIONS 18'2 SECTIONS 21' 158 DIA.GALV.AIRCRAFT TYPE i, ` i ® � �s� O 03�6'-9' 1 SECTION IB' 3 SECTIONS 21' LE&NICO-PRESS SLEEVE-i-- 1 i 1 � OPTIONAL VENTLA i= O ZW MIN. 5 TO 1 SAFETY FACTOR 1 11 I i (J)5'WIDE AT 7"O.C. MAX. FLUSH FACE L3 0 7' 4 SECTIONS 21'- 1 1 OPENING AN NOT TO EXCEED WOOD GRAIN DESIGN W 7'-J" - - i 5 1 120 SO. A CDESIGN � mm ami 7'-6' S SECTIONS I8'- 6"X 3"X 0.1' 7'-9' 4 SECTIONS 18'1 SECTION Z1' 11 i 0 T e' J SECCICNS 18'2 SECTIONS 21' WITF1 2 14% 5 8"SMS `�11 `` U m MAX. DOOR WIDTH 8'-3' 2 SECTIONS 18'3 SECTIONS 21' () A / 9'-4' O W-6' I SECTION 18" 4 SECTIONS 21' `--�--''' W-9' S SECTIONS 21"- BRACKET BRACKET INSIDE ELEVATION 9' 6 SECTIONS is'- STD. LIFT DOOR LOW HEADROOM RAISED PANEL EMBOSSED DOOR ' _g-JL. 5 SECTIONS 18'1 SECTION 21' DOOR OPTION 9'-6' 4 SECTIONS 18"2 SECTIONS 3 SEC71DNS 18'3 SECTIONS 21' 7-7/8°X 3-1/8°% .010° 10' 2 SECTIONS 18'4 SECTIONS 21' STEEL PLATE DAD DOORS INC. 0 R ' iv-3" 1 SECTION 18' 6 SECTIONS 21' CENTER STILE WITH(4) (114 X 3/4'SDS Hurricane Master®Model 824/811 ID'-6' 6 SECTIONS 21'- Max. Size 9'-4" X 16'-0" High ID'-9' 8 SECTIONS Ill'1 SECTION 21' OUTSIDE 914 X_3/4"SELF DRI NG SCREWS MAY BE USED '�S 11' 5 SECTIONS 10'12 SECTIONS 21' HANDLE END STILE IN LIEU OF 914 X 5/8'SMS With Window Lite Option 11'-3" 4 SECTIONS 18'3 SECTIONS 21' 11'-6' 3 SECTIONS 18"4 SECTIONS 21' THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT DESIGN PRESSURE RATING = + 50.0 PSF 1I'-9' 2 SECTIONS 18"5 SECTIONS 21• _ - 60.0 PSF LOCK BAR GUIDES ..11 12' 1 SECTIONS 18'8 SECTIONS 21' INSTALLED ON END STILE 1z'-J' 7 SECTIONS 21'- WITH (4)X74%5/e"SMS GENERAL NOTES 12'-6' 6 SECTIONS 18"2 SECTIONS 21' " 125-9' 5 SECTIONS 18'3 SECTIONS 21' 0 TBT X .6W LOCK BAR 1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE 1J' 4 SECRONS 18'4 SECTIONS 21' ENGAGES IN TRACK REQUIREMENTS OF THE FLORIDA BUILDING CODE(FOC)FIFTH EDITION(2014) 13-3' 3 SECTIONS 18'S SECTIONS 21' ON EACH SIDE OF DOOR INCLUDING HIGH VELOCITY HURRICANE ZONE(HVHZ). ll j -2 SECTIONS 18'6 SECTIONS 21' 2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. EO9r:JAVAD AHM AD t1R�ODUCf at vam .0 9 I SECTION 18" 7 SECTIONS 21' OUTSIDE KEYED LOCK (OPTIONAL ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WILLL CJVA �a�411y 1Milar14' a SECTIONS 21'- LOCK BAR LOCKING SHOWN DRESSING OR STUCCO. FIA.PE 70592 aww" C.AN. 38 14'-3' 8 SECTIONS 18'J SECTIONS 21' ALTERNATE TO SPRING LOADED SLIDE BOLT 3. ALL BOLTS,NUTS AND WASHERS SHALL 8E ZINC PLATED CARBON STEEL. ft)� 14'-6' 5 SECTIONS 18'4 SECTIONS 21' LOCKS SHOWN ABOVE G $ f! 14'-9' 4 SECTIONS 18'5 SECTIONS 21' 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN 13' 3 SECTIONS 18'6 SECTIONS 21' THESE DETAILS ARE NOT PART OF THIS APPROVAL. _15'-3'.,._2 SECTIONS 18'7 SECTIONS 21' 3. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. A Q 015 drawing no. 1 SECTION 18 B SECTIONS 21' DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA 01-09 11 1' 9 SECTIONS 21'- BUILDING CODE,TAS-202,TAS-201 h TAS-203 FOR LMR AND _ 16' 6 SECTIONS is;!Z SECTIONS 21' ASTM E1886-05/ASTM E1996-09. eheeL l of 5 24 CA STEE®RIV�PANELU " 3/16"ALU I '1 U FLAPS BENT OVER PANEL21/2"PUNCHED HOLES•.024"STL PANEL 0 4"O.C. OUTSIDE OF DOOR Q F 4zo B� j �l STEEL TRACK BRACKET FASTENED SOLID BRASS DOOR VIEWER TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 5/16'X THREADED) LAC SCREW INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE (FULLY THREADED) END STILE (o: m ONE PER BRACKET POSITIONED AT EYE LEVEL o 0 ANCHORS AT TRACK BRACKET: p OPTIONAL STOP MOULDING A) 3/8'DIA.POWER-BOLT BY'POWERS' w j FOR CONNECTION OF WOOD BUCK BY DOOR INSTALLER 2'MIN. EMBED INTO CONCRETE Q TO MASONRY SEE NOTE ON SHEET 4 1-7/8°MIN.EDGE DISTANCE (U 1 SMS PER HINGE 3/4'X 2'X 2-1/2"% 18 CA STEEL g)�/8"DIA.HLC SLEEVE 'HILTI' ? Z 8 'gym m END STILE,CONNECT TO PANELS WITH w 1/2"% 1-3/4°% .059'FORMED STEEL FLIPS AND 3/16"ALUM RIVETS I-1/4'MIN. EMBED INTO CONCRETE OR FILLED BLOCK -I (n rn pOC I SOUTHERN PINE GLUED TO PANEL AND SECURED TO SEE DETAIL ABOVE 1-5/B'MIN. EDGE DISTANCE INTO CONCRETE O O 3 G 0.55 S.G. EOG D ST:!•• END STILE WITH 3/16'POP RIVETS O 12"O.C. 4"MIN. EDGE DISTANCE INTO FILLED BLOCK H O 0 ° • EDGE CONCRETE Fc -3000 PSI MIN. � p rn 1-7/8'%2-5/8'% .045"STEEL CENTER STILE,GLUED AND RNETED DISTANCE I C-90 GROUT FILLED BLOCK I'm 2000 PSI MIN. •+ TO PANEL W/(4)3/16'RIVETS I p N= 1 1/'MIN. �I PQP RIMS :. . X14%5/8'S.MS. I 1 4/HINGE I I b1- ANCHOR TYPE A OR 8 1.9"% 2.19"X 3.3"X 102" ((1 PER BRACKET H STEEL TRACK BRACKETS S'E�E SHEET 3 FOR BRACKET SPACING u CIVIL SEE SHEET 3 FOR;12 u $g 1 I 1 1/4-20 SS BOLT& NUT o d ,d'��'•, 7-1/2'% .071 GALV.STEEL CENTER HINGE 7-1/2"X 3'X .071' c" El 7/16'PUSHNUT SECTION B—B ENO ROLLER HINGE O INSTALLED ON ROLLER SHAFT PRWt1C 9AVLgW Q Engn JAVAD AHMAD EL TRACK INTERIOR SIDE 1.82'DIA.X .50'STEEL ROLLERS (STD.) CLb A 3 FIA.PE 70592 EL %2-1/8"%1'(STANDARD) 1.82"DIA.X .50"NYLON ROLLERS(OPTIONAL) CAkNSHarv..Nn�7 34�GA.X 3-5/16'% 1-1/2"(OPTIONAL) 2.75' DIA. X.50'STEEL ROLLERS(OPTIONAL) OOeOAl09pal y 3 2.75"DIA X .50"NYLON ROLLERS(OPTIONAL) WFASTENED4-20%55//8'TRUSS HD. WITH 5"STEM By —� SLOTTED M.S.&LOCK NUT drawing n0. MAR 01-09 sheet 2 of 5 POP RIVETS 2 X 2 X 1/8"HORIZ.ANGLE (� " 2" 5/16"X 1-5/8"LAG SCREWS INTO WOOD OR HORIZ.TRACK SUPPORT, SPOT WELDED TO HORIZ.TRACK V 2-3/4"X 5-1/2'X 3"X.104' 5/16°SLEEVE ANCHORS CENTER SUPPORT REDD. ON DOORS WITH TWO WELDS AT 1-1/2"APART GA.TOPVROLLEL BRACKET ON EACH SIDE WITH 1-1/4'EMBED INTO MASONRY EXREEDING B FT.IN HEM" FIRST AT J"O.C. �I FASTENED W/(6) 0 14 X 5/8'S.M.S. - 3 PER BRACKET p+ REST AT 9"O.C. Z CONNECTED TO FLA/BRACKET ANGLE LID HK.GALV.STEEL ADJUSTABLE D TO SPRING SHAFT GUIDE WITH SLIDE FASTENED TO RACKET 2-1/2'X 4-1/4'X 13 CA STEEL PLATES � A`, O Z W/5/16-18 X 3/4°HEX HEAD _ _ WELDED TO 1-1/2°X 1-1/2"X 14 GA.ANGLE -- (2) 1/4-20 X 5/8'BOLT&NUT W M.SCREWS&NUTS. fASTENEO TO TRACK - -- 0. TOP BRACKET WITH(4) 1/4-20 55. BOLT&NUTS -- HORIZ.TRACK LENGTH =OPENING HEIGHT PLUS 12" (STANDARD) - Ya O TOP BRACKET nA (OPTIONAL) VERTICAL TRACK V = LOW HEADROOM DOOR 14 GA GALV.STEEL TRACK 2-1/8'X 1"X.060° VVVV p 142 SECTION A—A C 0 w R HORIZONTAL REINFORCEMENT O Q Q o= 1/2'X 1-3/4"X.059°FORMED STEEL 2'X 5-1/2"X.104' p+(A GLUED TO PANEL AND FASTENED TO GALV.STEEL a-o VERTICAL STILES WITH FASTENED W/ 4)y 14 X 5/8-S.M.S. O:N C a a (2)3/16'POP RIVETS TOP 91-LER BRACKET FOR Q u1 LOW HEADROOM DOOR OPTION {L Z N F-� 5 0I 5 HORIZONTAL REINFORCEMENT DOOR " SECTION HEIGHTS BRACKET PLACEMENTS ��q� 1/2°X 1-3/4'X.059'FORMED STEEL HEIGHT 1ST 2ND 3RD 4TH 5TH 81 82 B3 84 B5 B6 97 BB GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH 6�0 '-0' 18'1B" 1B°18"N/A 1"TO 2"11-3/4" 23" 34" 45" 56" 67" (2)3/18"POP RNEfS 6'-6' 21'18" 18'21"N/A 1"TO 2"11-3/4" 23" 34" 45" 56" 67" 5/16'MEETING RIR 21"21" 21"21"N/A 1'TO 2'11-3/4" 23" 34" 45' 56" 67" - 7'-6" 18"18" 18' 18" 18°1"TO 2"11-3/4" 23 34" 45 56 67° 78-1/4" 1.82"DA. X.50"ROLLERS rs _ 8'-0" 21"18" 18°18" 21"1"TO 2"11-3/4" 23" 34" 45" 56" 67" 78-1/4 °0 W/ .44 DA.%4-1/4'STEM = •-SECTIONS ARE NUMBERED STARTING AT THE BOTTOM o M x FOR DOORS MORE THAN 8 FT, HIGH,USE ADDITIONAL TRACK BRACKETS AT 10"O.C. OPTIONAL NSULA7IONS: _¢ q 13Y'DYP ACT PRODUCTS LCC' EPS-EXPANDED POLYSTYRENE a _ o� 1.9'X2.19"X3.3'% .080" U r DENSITY a 1.05 PCf STEEL TRACK BRACKETS (Q9 Z Z ,Amo N.OJI.011-0928.07 n 2-3/16'HIGH J aO w w u OR m CONNECTED TO TRACK WITH Q to ISO-25 POLY-ISOCYANURATE Z � m p= DENSITY=2.0 PCF ) 1/4"BOLTS&NUTS. / O O$ w w N.O.A./11-0928.06 OC]Z=H BY'CELLOFOAM NORTH AMERICA' cn w DENSITY- 1.03 PCF Rr / Q N N.OA 010-1129.04 _ OR BY'INSULFOAM LLC' - DENSITY-0.92 PCF m .®' N.OA 114-0311.08 6 O\14 GA.GALV.STEEL ROLLER HINGES FASTENED W/(4)014 X 5/8'SMS m ° � MIN. .024 ROLL FORMED STEEL PANEL DRAWING OUALTN 0-40 u _— MIN.YIELD STRENGTH s 34 HSI WITH PRIMER AND BAKED-ON TRACK CONFIGURATION w o 15 POLYSTER PAINTED TOP COAT APPLIED TO BOH SIDES OF STEEL �= Naory=a$ IM VERTICAL LIFT HIGH l� STANDARD LIFT LOW HEADROOM .>o u$ - - DOUBLE TRACK 12 GA.GALV.STEEL AVAILABLE TRACK OPTIONS BOTTOM BRACKET FASTENED W/(4)014%5/8"SMS Engr.JAVAD PHMAD Q 4 CML FIA PE/70592 PRODUCCREVLSW CA.N.,S BOTTOM O SEE SHEET OPTIONS TDAN o A �_. Z0�5 B) drawing no. SECTION A—A sheet 3 of 5 3 4" REINFORCEMENT O OGE FORMED 1EEL'%.058" �li V O OGEDIST. BB% 1' 1� SELF DRILLING SCREWS W z 1-1/2"MIN. OR a 3/16"'RIVE%'STEEL RIVETS SELF DRILLING SCREWS Z I GE DIST. I m 0 o MULTIGRIP W/DOME HEAD 3/16•RINE%'DOSTEEL HEAD fy AT 48'O.C. IY MULTIGRIP W/DOME HEAD j a 3 AT 48'O.C. REINFORCEMENT a' m 1/2'X 1-3/4"X .058" D w FORMED STEEL O + a �t 2BY 1/4'DIA. UIC SCREWS 28Y 1/4'OLA.LAG SCREWS �O u WOOD BU �-AT 6'FROM ENDS 2BY WOODBU `AT 6'FROM ENDS A I AND 19 O.C.MAX. WOOD I 1 AND 19'D.C.MAX. W's ADAPTER UM STRIP ADAPTER c R STEEL 0 A.Q G C) RUBBER W'STRIPPING RUBBER W'STRIPPING Q 9 3 G 1 050 —� T— .040 LL ZZ9 Uu��fS- .224I .534 .700 340 Q bi H ��1.750-J� —f It 1.790 BOTTOM SEAL OPTIONS OPTION 'A' OPTION 'B' o= � WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG-0.55 MIN.) 0 n THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT M1 TO WOOD STRUCTURES.IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN CW.7 Q WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. LL ANCHOR SPACING FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD,INSTALLATION MAY BE _..._ Q Z n VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. _ ANCHORS STRUCTURE EMBED SPACING EDGE GIST. O _ Z m • 3 8 HLC SLEEVE BY'HILT]" CONC. 1-1 4 8" 1-5 8 -J t/►rn o I 3/6 HLC SLEEVE BY HILTI FILLED BLOCK 1-1 4" " 3 8"OYNABOLT DY'ITW' CONC. 1-1/2' _ B" 2- O 0�+f�•J STEEL STRUCTURE BY OTHERS 3 8"DYNABOLT BY'ITW FILLED BLOCK 1-1 2 8"_ 2-11/4' 5/16'X 1-5/8' 3 8 POWER-BOLT BY POWERS' CONC. 2' 8" 1-7 8 U p Z in LAG SOREWS MUST SUPPORT THE LOADS IMPOSED 3 B SLEEVE-ALL BY SfNPSONS CONC_ 1_1 2 B' 1-7 8 cn U) n AT 12"O.C. BY DOOR SYSTEM - mm O1.J CONCRETE f'c -3000 PSI MIN. Q N C-90 GROUT FILLED BLOCK Fm 2000 PSI MIN. 0 _ ' 5/16'010.BOLTS WOOD'BUCK CONNECTION TO MASONRY >' WITH WASHER k NUT —� AT 12"O.C.MAX. b • EDGE DIST. PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 1' GROUTED REINFORCED MASONRY BLOCK WALL OR CONC.COLUMN WITH 1 1/4"ULTRACON BY'ELOO'WITH SPACING OF 2000Z 16"D.C. INTO GROUT FILLED BLACK WALL,WITH 2-1/4'MIN.EMBED 18"O.C. INTO 3000 PSI CONCRETE,WITH 1-3/4"MIN.EMBED 2-1/2"MIN.EDGE DISTANCE � 1-1[4'X 2-1/2'X 14 GA U R 1-1/2' 1-1/2' CONT..STEEL aArvNGLE 1-1/2' & 1/4"TAPPER BY'POWERS'WITH SPACING OF - 14'O.C.INTO GROUT FILLED BLOCK WALL,WITH 1-1/2'MIN. EMBED 12 GA GALV.STEEL 16"O.C.INTO 3000 PSI CONCRETE,WITH 1-3/4'MIN.EMBED / FIAT BRACKETS f3"LONG 2-t/8'X 1'X 14 CA y a m 3"MIN.EDGE DISTANCE 1/1 FI %2-1 2 AT 12'O.C. IN DOOR OPNG. GAL.STEEL TRACK .+ FILLET WELDS FASTENED TO TRACK PLATES 3/8'CONFLIX BY'ELCO'OR . AT 12"O.C.MAX AT 18'O.C.ABOVE DOOR OPNG. W/(2) 1/4-20X5/8'TRUSS NO. 3/B'LDT BY'ITW WITH SPACING OF CONNECTED TO CONT.ANGLE S O7TED M.S.&LOCK NUT 24'O.C. INTO 3000 PSI CONCRETE,WITH 2-1/2'MIN.EMBED W/(3)SPOT WELDS AT EACH 510E y 2'MIN. EDGE DISTANCE CONTINUOUS ANGLE TRACK REVERSE TRACK CONTIUWS ANGLE TRACK a o d H $ 3/8-HLC SLEEVE BY'HILTI'WITH SPACING OF TO WOOD_BUCK TO STEEL TO CONCRETE AND FILLED BLOCK '�°c LL S 8'O.C. INTO GROUT FILLED BLOCK WALL,WITH 1-1/4"MIN. EMBEO,4"MIN.EDGE DIST. o 18"O.C. INTO 3000 PSI CONCRETE,WITH 1-1/4"MIN.EMBED AND 2-1/2MIN. EDGE DISTANCE ALTERNATE TRACK INSTALLATION _ Engn JAVAD AHMAD Q PREPARATION OF JAMBS BY OTHERS CML PROMIcEallVall) FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY FIA,PE B 70592 ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED C.AN.'3538 BY DOOR SYSTEM. Ampnoe Tb 31 OZ . L $ FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD,DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. Y) drawing Do. MAXIMUM EXTERIOR(+)LOAD PER JAMB (9.33' X SO PSF)/2 233.3 Lbs per Ft. 1015 LO —09 MAXIMUM INTERIOR(-) LOAD PER JAMB-(9.33'X 60 PSF)/2-279.9 Lbs per Ft. sheelof 5 , ' * PLASTIC COMPLIES WITH .500 r1-.250 V DOOR PANEL CHAPTER 26 OF FBC 24 GA (.024)STEEL MIN. SEE EVIDENCE PAGE o 1.765 ,.725 7/16°CIA.WASHER 1.144 d S j A (� Ia X 3/4"SMS 21 3/4• C 3/B•FROM ENDS MAX. .176 .800 d t III 1 t1 AND 7.O.C.MAX. WDW.WIDTH 0 Q D 1 � * EXTERIOR FRAME * INTERIOR FRAME i 11 1 W 18 1/8" RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION 3 90 n 1 1 , 1 (4)88%3/4•SMS = j Q LL � ® 1-3/8•FROM ENDS \3 \0 0 I t AND 6-1/2°D.C.MAX, o u, Q W c+l ;III 1 j Y a, o YI l� L 1 - ED �--7 I I I 175 X.062 DEEP 1111 GROOVE El I I 1111 LI y I I 1111 O 1111 m i. i. .. O O 1111 1/4"POLYCARBONATE LEXAN � � i' p W M I BY'SARIC INNOVATIVE PLASTICS' W > 1 MOA 113-0717.01 �� I 0 ¢-j �E D: II11 Z0 00 In N olit 1IS 0 o WWW 1 1 1 1 m IS 0 3;; 5 O z 0 H N p 0) v 1�1� � •/ A Q0) 1111 LI I 0 11 I I I'll .1175 GROOVE•062 DEEP IIII I.Ala�18 S5m O€ €S m I (4)18 X 3/4°SMS INSIDE ELEVATION �+ 1 111 ; ® 1-3/a•FROM ENDS RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS " j 111 I AND 6-1/2.O.C. MAX. 1 WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION O I /B X 3/4'SMS C 8 3/8•FROM ENDS 175 X.062 DEEP - 1 I AND 4-1/2"O.C.MAX. GROOVE d N 4 0 8 S _i /8 X 3/4°SMS ®3/8•FROM ENDS AND 7"O.C.MAX. r- _- -_- Eapl:JAVAD AHMAD Q g Cori 7/16°DIA.WASHER _ _ _ _ _ _ _ Z. _ _ _ _ _ _ _ FLA.PE 70 92 PRODUCT�VL9P� � ftflq11 Q 1 ODOR PANELEXTERIOR L_ 24 CA. (.024)STEEL MIN. DOOR PANEL 15/16"MIN. D.L.OPG. 131' PNdIM CaM,d drawing O� 24 GA. (.024)STEEL MIN. GLAZING BITE WINDOW WIDTH sheet 5 of 5