HomeMy WebLinkAboutInspection Affidavt Public Works Department
Code Compliance Division
* 2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2172 Fax: 772-462-6443
INSPECTION AFFIDAVIT
Re: ermit# ' l
I, licensed as a(n)Contractor*/Engineer/Architect
(Please print name&circle license type) *F5468 Building Inspector
*General,Building,Residential or Roofing Contractor or any individual certified under 468 F.S.to make such an inspection.
On or about I did personally inspect the roof deck nailing and/or
(Date) (circleK�s
hat apply)
secondary water barrier work at: I(�V1 ?cqrzrz.(
(Job site address)
Based upon that examination I have determined the installation was done according to the
Hurric ne Mitigation Retrofit Manual (Based on 553.844 F.S.)
i nature and Seal License#
STATE OF FLORIDA
COUNTY OF -
Sworn to ani subscribed before me this rl U day of. 0 ������.,, LASHAHNA INGRAM
by ��� Who is personally know to me or who' nU°`��' Notary Public-state of Florida
as identification. c•: ; My comm.Expires Dec 20,2018
Nr• `oma; commission#FF 177249
°'••� Bonded through National Notary Assn.
Notary Publi&osta
Signature ofCommission (Seal)
En 09/17/09
Mills, Short 8 Associates
CIVIL I STRUCTURAL I SURVEYING I ENVIRONMENTAL
CERTIFICATION OF AUTHORIZATION 30698
August 17,2015
St.Lucie County Building and Inspections
2300-Virginia Ave.
Fort Pierce,FL 34982
Re: Wind Load on Roofing Components Analysis for a Mobile Home Structure
Pellegrini Residence
13959 Zorzal Ave.
Fort Pierce,FL 34951
Permit#
To Whom It May Concern:
This letter is written to provide certification that.I,.as a Professional Engineer, have been retained to establish
compliance with the St. Lucie County codes and regulations pertaining to the roofing installation at the
residence listed above. I have analyzed the proposed roof modification', and have determined the "Gulf Coast
Metal, Inc." Gulf Rib Metal Roof System (FL #11651:22) may be installed' on the'existing mobile home
structure; and will not compromise the structural integrity. The modifications and application will be in
compliance with the 2014 Florida Building Code,and F.A.C. 15C-2.0081 (Mobile Home Repair)section(1)(c).
Furthermore,_the"Gulf Coast Metal, Inc."Gulf Rib Metal Roof System(FL#11651.22)is rated to a maximum
design pressure rating of-159.25 PSF,and the"Palram Americas,Inc."Clear Panel system is rated to-45 PSF,
and may be used in zone 1.My analysis was based on the design criteria below:
Wind Design Speed: 160 mph(Volt)
124 mph(Vasd)
Exposure.Category: "C
59
GCPI:Main Structure +%-0.18(Enclosed)
Zone 1:+17.7/-28.1 PSF
Zone 1+17.7/-573 PSF
Zone:3:+17.7/-96.4 PSF
All provisions of the Florida product approval (FL#1,1651.22)listed above.must be followed. Including,
but not limited to, the underlayment, and replacement of wood decking (if required) that is composed
15/32" CDX (or OSB) mina with 8d ring shank nails @ 6" O.C. in the field & at the corners. If the
decking is less than 15/32"the attachment method listed will be in addition to the existing.Due to the low
slope of the.metal roofing system, Schnee-Morehead SM9200 JAWS adhesive or equivalent must be used
per FBC 1507.4.2.
The engineering services addressed therein have been performed and based upon my professional engineering
knowledge, technical documentation, information and belief, and in accordance with commonly accepted
\ \,,prbbhlilt'resig9nsistent with applicable.standards of practice, and is not a guaranty or warranty, either expressed
t2it� oylfi you have any questions,please feel free to call me at(772)473- 2571.
S C Iy,
0 X018
!' Jason W. Short.PA,�.,`14.ASCE
PEUMTngirie_`/
c9)4 ftnfib\gdYstruction&Roofing, Inc.
800 Eighth Street I Vero Beach FL 32962 772.226.7282