Loading...
HomeMy WebLinkAboutRoof Inspection Affidavit Public Works Department Code Compliance Division � COUNTY 2300 Virginia Avenue Fora Pierce, FL 34982 . 772-462-2172 Fax: 772-462-6443 INSPECTION AFFIDAVIT Re: Permit#—i COPY � I, %"1 S���'�OJr— licensed as a(n)Contractor*/Engineer/Architect (Please print name&circle license type) *FS468 Building Inspector *General,Building,Residential or Roofing Contractor or any individual certified under 468 F.S.to make such an inspection. on or about , I did personally inspect the roof deck nailing and/or (Date) th osethat apply) secondary water barrier work at: l . . (Job site address) Based upon that examination I have determined the installation was done according to the Hurrican Mitigation Retrofit Manual (Based on 553.844 F.S.) Si toe and Seal License# STATE OF FLORIDA COUNTYOF �n'�1.5t"c3t� Sworn to and subscribed before me this.Q day of 20J bVt, S1��1�`13C�,1C Who is personally known me or who has produced as identification. 'Notary Public, a rid Signature of N tary: 6 - Commission Nu ber. (Seal) ,`.SPRY n�a. LASHAHNA IN6RAM En 09/17/09 ° .`�:; Notary Public-State of Florida iL My Comm.Expires Dec 20,2018 o�oc Commission#FF 177249 Bonded through National Notary Assn. Mills, Shoat 8 Associates CIVIL I STRUCTURAL I. SURVEYING I ENVIRONMENTAL CERTIFICATION OF'AUTHORIZATION 30698 August 17,201.5 St'.Lucie County Building and Inspections 2300,Virgmia Ave. Fort Pierce,FL 34982 Re:Wind Load on Roofing Components Analysis fora Mobile Home Structure Beckman Residence 11 Sierra Del Norte FortPierce,FL 34951 Permit# To Whom it May Concern: This letter is written to provide certification that I, as a Professional Engineer;.have been retained to establish compliance with the St. Lucie County codes and regulations pertaining to the roofing installation at the. residence listed above. I have analyzed the proposed.roof modification; and have determined the"Gulf Coast Metal, Inc?' Gulf Rib Metal :Roof System (FL #11651.22) may be.installed on the-existing mobile home structure, and will .not: compromise the structural integrity. The'modifications and application_will be in compliance with,the 2014, Florida Building Code;and F.A.C. 15C-2.0081 (Mobile Home Repair)section(1)(c). Furthermore,the"Gulf Coast Metal;Inc."Gulf Rib Metal Roof System(FL.#11651.22)is rated to a maximum design pressure rating of 7159.25 PSF.My analysis was based on the design criteria below: Wind Design Speed: 160 mph(VUn) 124 mph(Vas d) ry Ex ,,.. Exposure Category: C P g COPY GCPI:Main Structure +/-0:18 nclosed� ) Zone 1:+17.7/=28.1 PSF Zone 2:+17.7/-57.3 PSF Zone 3:+1;7.7/-96.4 PSF All provisions of the.Florida product_approval (FL#11651.22) listed above must be followed:Including, but not limited the underlayment and application. Per section.l'510.3 of the 2014 Florida Building Code it isnot required to re=nail sheathing,over 1 layer or less of existing shingle application (ref: "Gulf Coast: Supply&Mfg., LLC".letter from'President Jonathan Sherrill). Due to the low slope of the metal roofing system, Schnee-Morehead SM9200 JAWS adhesive or equivalent must be used per FBC 1507.4.2. The engineering services addressed therein have been performed and based upon my professional engineering knowledge; technical documentation, information and belief, and in accordance with commonly accepted procedures consistent with applicable standards of practice, and is not.a guaranty or warranty, either expressed r lei+7Should you have any questions,please feel free to call meat(772)473-2571. r so4kW. Short,P.E..:M.ASCE 4 rincipal Engineer`, �1 STATE OF .�y'• CR:tlautie'CUffstruction&Roofing,Inc. 800 Eighth Street Vero Beach FL 32962 1772.226.7282