HomeMy WebLinkAboutProduct Approval `Florida Building Code Online Page 1 of 2
~-rte
a
8 v3v _ i �$
, °F > � � a
BCIS Home Log In z User Registration Hot Topics Submit Surcharge Stats&Facts Publications ; FBC Staff 's BCIS Site Map Links i Search
BusinesProdut
� �
Professik.dI USER:Public User
APPrOVBI
'11-gU Flo I
Product Approval Menu>Product or Application Search>Application List>Application Detail
U' FL# FL10674-R10
Mal
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen od
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 8/21/2015
'Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 04/22/2015
Date Validated 04/23/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R10 II 2015.04 FINAL ER OC__ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-RSO.Ddf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R10.Ddf
Created by Independent Third Party:Yes
f3�31:Lt NE'.Xt
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
90 d hssk
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgtBNbEY5 V%2... 8/21/2015
}> EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
s 353 CHRISTIAN STREET,UNIT#13
TRINITYIERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-115
One Owens Corning Parkway FL10674-R10
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 5: 04/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
�•••c'-r""tC The facsimile seals
Robert J.M.Nieminen,P.E. - .Thisdoppearing wastserveizean Robert Nieminen,
���^•�?.L��ss`" P.E.on 04/22/2015.This does not serve as an electronically sign ed
Florida Registration No.59166,Florida DCA ANE1983r"......� document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
T I I ER®
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance
with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Kaftif Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic`and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire—are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition Duration, Duration® Premium Cool, Tru Definition® Duration Designer Color Collection,
TruDefinition®Oakridge®,Oakridge and WeatherGuard'HP are fiberglass reinforced,laminated asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard® HP Hip & Ridge Shingles,
ProEdge Hip& Ridge Shingles and DuraRidge- Hip& Ridge Shingles are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings ofthis product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to
Vasa=150 mph(V„1t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to
Vwd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 FL10674-R10
Revision 5:04/22/2015
Page 2 of 6
TRINITYIRD
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
➢ Berkshire®shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshirer°"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Plus requires minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Classic°&Supreme:
Normal Mansard or Area para Normal Mansard or Area pare
Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y
Area pare vientos normales Areas vientos fuertes Area para vientos normales Areas vientos fuertes
�• (Al �" jt" z lel Cz• t•� t�zt fAi �� t" t" z• f6) rz" I' '
tr �r
a
5"Exposure 5 5/8"Exposure
Exposicidn Exposicici
6.2.6 Minimum Nailing—Berkshire°:
Sealara strip Sealant strip
La Pira de sellador La rira de milador
t" f s•
't--s • r--► •4 �0 • • -►•�--►•
BV{'
r
r -
t
2. Montt rooting cement
Cerrrenlo de!echo de astatto
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 FL10674-R10
Revision 5:04/22/2015
Page 3 of 6
QTRIERD
6.2.7 Minimum Nailing—Devonshire*"":
Nails
7: r
>� TE•. f J
Nails Ten 1"Spots of Asphalt Roof Cement
6.2.8 Minimum Nailing—Duration®,TruDefinition°Duration, Duration°Premium Cool&TruDefinition'Duration'Designer
Color Collection:
4 Nail Pattern 5 Nail iM1 sardaru 31eep Sbpe
,atm-Mmen SUTA3
Esquema do d efavos Pattern anaandlep dcut ou.
Esquema — er,mrmorvde fes
SumNaif fastening arae width de 6 efavos 3wdasfipia gnus er
Area deelavosSureNail3 e e 1eaSmet7a3''rbyarra
umeda�treare.
p t. Su;Mi2tl" ♦ Swetlaip
4itela�9 tastenmgg
auawdth � ar:atviUlh
tY—! Araade '1" Aram01, — `t nates
wlav 72' ^t'L'~ SUI ifs
I � Imo—^
55s'Exposure Nails 55"Exposure j
f E pug.de exposfd6n Geavos 5.s pulq.de exposici6n
Sts'Exposure Nails 5V Exposure
55i pulg.da erposlridn Clavas 5A6 puig.de expoOdtin
6.2.9 Minimum Nailing—TruDefinition®Oakridge°,Oakridge°:
4 Nail Pattern 6 Nail Pattern
Esquema can 4 efavos Esquenia con 6 clavas
t• t.
����.11 t• r
55/8 Exposure Nails 5518 Exposure Nails
Exposicidndo 56618pu;g. Clavas Exposici6n de 55/Spulg. 56/8"Exposure Clavas 5 518"Exposure
Erposicfdn de 5518 pulp. Erposlcf6n de 5518 pufg.
6.2.10 Minimum Nailing—WeatherGuardm HP:
1 "Y 1 singleEside View
2. hEda/
NO••: Fu*wm Thewtdt Nil lire
rtmasaIir dwfl}d&
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 FL10674-R10
Revision 5:04/22/2015
Page 4 of 6
RINI Ty ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire'Hip and Ridge Shingles, High Ridge, Hip& Ridge with Sealant, WeatherGuard® HP Hip and
Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle. Installation of DuraRidge'"Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind
resistance and installation limitations,including the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing–Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
.�— Prwatlng4Mnd ,r�� \
Di—Wo // .\ \\A\ ioPVrew SiUeView
i Nails—......... ...... \i\:. l��N�\ I Nais ---Nails
V\ � TUP LanUrwtul 2'��), 1
I Piece
\\` \
04
i NN \ I I 1 I I
�Posure ,cc— ei
12" sl
6.3.4 Minimum Nailing–Hip&Ridge with Sealant: II
em Fig. 2-High Wind Fastening Pattern
(4 Nails)
rim Shingle—►
nd Discard
Exemss 22
Sealant —�
Strip 124►
'Fastening, 55/9" 5"Exposure
Distance I
12„
6.3.5 Minimum Nailing–WeatherGuard®HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A Provaging Wind i1\ 4 4 � Top View
—Direction
Nails
Nails Nails
\ A\ T
\4.................._..._._..— .. i y v v
r...............
Eiposum
\\` 5^ Exposure +I
i
_Y
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5
Certificate of Authorization tl9503 FL10674-R10
Revision 5:04/22/2015
Page 5 of 6
* I ESD
6.3.6 Minimum Nailing-Pro Edge Hip&Ridge Shingles:
Prevailing Standard
Wind DirectionFastening
Sealant Strip Pattern
&"Exposure T It
• 92' Sealant
Fasten 71h„ 7`j2
6°Exposure
Cover Exposed {I I+
Fasteners with
Roof Cement
6.3.7 Minimum Nailing—Durallidge'"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pravaiing Wind Dirocdon Top View
�iroaian dornimnto du omt Vue en pian
Girocdwdairirntoprwkmiranta i" Vismstperior
v t TI ae-
2 e" _._...__ ..._. cmc
p �- r OvnensCaesd SuroNaii' s
arae
I I I
II-P
A
..._N i i I I g I I—
r i i «I�a
.rrbpa.n-s u I a$
I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization 119503 FL10674-R10
Revision 5:04/22/2015
Page 6 of 6
Florida Building Code Online Page 1 of 2
.a:,"n BCIS Home Log In c User Registration Hot Topics ? Submit Surcharge Stats&Facts i Publications t FBC Staff i BCIS Site Map Links Search i
3s.` ,
BusinesC'm
Product Approval
Professional USER:Public User
q
-idol:, n
Product Aooroval Menu>Product or Application Search>Application List>Application Detail
r FL# FL16906-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived i;...
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
r Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL16906 R1 COI TBM14001.1 2014 FPA TRI-BUILT Self Adherino HT
Underlayment- FINAL.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvBwYu9TrZN... 8/21/2015
Florida Building Code Online Page 2 of 2
Date Submitted 04/19/2015
Date Validated 04/20/2015
Date Pending FBC Approval 04/22/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
16906.1 TRI-BUILT Self Adhering HT ASTM D 1970 underlayment
Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16906 R1 II TBM14001.1 2014 FPA TRI-BUILT Self
Approved for use outside HVHZ:Yes Adhering HT Underlayment-FINAL.odf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FI-1.6906 R1 AF. TBM1.4001.1 7.014 FPA TRI-BUILT Self
AcJhering_HT Untlerl<3.yrnellt-FINAUxif
Created by Independent Third Party: Yes
6adc Pdext
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
91 F0 utak RRI
yyc 1
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZN... 8/21/2015
'domph—long% 11 W1 Certificate of Authorization No. 29824
17520 Edinburgh Drive
�> Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: TRI-BUILT Materials Group Issued April 15, 2015
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485
www.tribuiltmaterialsgroup.com
Manufacturing Location: Petrolia, Ontario, Canada
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.5.3, 1507.5.3.2,
1507.7.3, 1507.7.3.2, 1507.8.8, 1507.9.9
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) HGC-140-02-01 ASTM D 1970 2009
PRODUCT DESCRIPTION AND APPLICATION
TRI-BUILT Self TRI-BUILT Self Adhering HT Underlayment is a self-adhered,ASTM D 1970
Adhering HT underlayment reinforced with a polyethylene film surface for use on steep slope roofs.
Underlayment
Roof Deck: The roof deck shall be constructed of closely fitted
plywood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8"gap at abutting joints.
Min.slope: In accordance with FBC requirements
Attachment method: The underlayment shall be attached by adhering
directly to the roof deck with minimum 2.75' side
laps and minimum 2.75' end laps. All side laps
seams shall be installed to shed water from the
deck. Priming of the roof deck shall be optional.
Min. application temperature: 40°F. Contact the manufacturer when installing at
temperatures below 40°F.
Allowable roof coverings: Roof coverings shall be mechanically fastened
through to the roof deck. Attachment of asphalt
shingles, wood shakes and shingles, slate
shingles, metal roof panels and shingles shall be
permitted.
TBM14001.1 FL16906-R1 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
TRI-BUILT MATERIALS GROUP
CREEK TRI-BUILT Self Adhering HT Underlayment
TECHNICAL SERVICES,LLC
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) The underlayment may be used as described in other current FBC product approval documents.
7) Roof coverings shall not be adhered directly to the underlayment.
8) The underlayment shall not be installed over existing roof coverings.
9) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
It5Y 'R'I11
Pi
P ......
E IV 2 015.04.1
No 74021 = c7° ' S 09:46:12
-04'00'
: 3% STATE OF :•41J
'• 4 Zachary R. Priest, P.E.
4 p R k O P����`� Florid Registration No.74021
'i,.,till,,
S j� -A �` Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBM14001.1 FL16906-R1 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.