HomeMy WebLinkAboutEngineering Joseph P. McCarty,Architect, Inc.
900 East Osceola Street
Stuart, Florida, 34994
772-287-6735 fax: 772-287-4618
DPR Registration Number 9639
FILE � .-
August 18, 2015
St. Lucie County Building Department
2300 Virginia Avenue
Fort Pierce, FL 34962
RE: 1840 Coppenhaven Road,Fort Pierce Re-roof
Wind Certification—Design Criteria
These plans are designed to the following standards
Florida Building Code 2014
Wind Speed—165 MPH V ult
Exposure"B"
Structure is enclosed
Internal Pressure Coefficient+/-.18
Design Pressures—maximum zone 3-30.4
Building Category II Importance Factor 1.0
To whom it may concern:
Please be advised that the above referenced is to be re-roofed with 26 gauge 5v-crimp roofing
manufactured by Metal Sales Manufacturing Corporation. Florida Building Code project
approval FL 15478.1. (NOA attached)with fasteners at 16" on center. This product is rated with
a design uplift pressures of 74:8 psf with fasteners at 16"on center.
This metal roof is to be applied over Trinity ERD Soprema Roof Underlayment. Florida Building
Code product approval FL 2569-R6
ood is to be nailed to the roof with 8d ring-shank nails,4" on center on
-- es and-6" on cente
iricereYy
- 1
- tel `L•' .- - _
�' Joseph P.- AcC`arty