HomeMy WebLinkAboutEngineering Joseph P. McCarty,Architect, Inc. 900 East Osceola Street Stuart, Florida, 34994 772-287-6735 fax: 772-287-4618 DPR Registration Number 9639 FILE � .- August 18, 2015 St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34962 RE: 1840 Coppenhaven Road,Fort Pierce Re-roof Wind Certification—Design Criteria These plans are designed to the following standards Florida Building Code 2014 Wind Speed—165 MPH V ult Exposure"B" Structure is enclosed Internal Pressure Coefficient+/-.18 Design Pressures—maximum zone 3-30.4 Building Category II Importance Factor 1.0 To whom it may concern: Please be advised that the above referenced is to be re-roofed with 26 gauge 5v-crimp roofing manufactured by Metal Sales Manufacturing Corporation. Florida Building Code project approval FL 15478.1. (NOA attached)with fasteners at 16" on center. This product is rated with a design uplift pressures of 74:8 psf with fasteners at 16"on center. This metal roof is to be applied over Trinity ERD Soprema Roof Underlayment. Florida Building Code product approval FL 2569-R6 ood is to be nailed to the roof with 8d ring-shank nails,4" on center on -- es and-6" on cente iricereYy - 1 - tel `L•' .- - _ �' Joseph P.- AcC`arty