HomeMy WebLinkAboutProduct Approval CREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued Apri113, 2015 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 hftp://www.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: U nderlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2,,1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1507.6.5, 1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8,T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-191-02-01REV ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2005e01 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2005e01 UL LLC(TST9628) 13CA12269 ASTM D 226 2006 PRODUCT DESCRIPTION AND APPLICATION TAMKOO ASTM Slate ASTM D 6380,Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. Min.slope: 2:12 Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"staggered end laps and in accordance with FRSAITRI 07230 for file applications. Allowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete tile shall be permitted in accordance with the FBC. TBP14001.1 FI-12328-R5 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. is CRK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKOO ASTM Tile ASTM D 6380,Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"staggered end laps and in accordance with FRSA/TRI 07230 for tile applications. Allowable roof coverings: Attachment of clay and concrete tile shall be permitted in accordance with the FBC. TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle valleys shall be permitted in accordance with the FBC. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 3-1/2" side laps and minimum 6"staggered end laps. Min.application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and clay tile roofing shall be permitted in accordance with the FBC. TAMKOO No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TBP14001.1 FL12328-R5 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEI1 TAMKO BUILDING PROINC. j� TAMKO Underlayderlayments TECHNICAL SERVICES, LLC TAMKO®No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete file, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKOO No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete file, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKOO TW Metal and Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Tile Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered end laps. Min.application temperature: 40"F Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and mechanically fastened clay and concrete tiles shall be permitted in accordance with the FBC. TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered end laps. Min.application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles and metal roofing shall be permitted in accordance with the FBC. TBP14001.1 FL12328-R5 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GRID TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Minimum application temperature shall be 50°F unless otherwise noted. Contact the manufacturer when installing at temperatures below the minimum application temperature. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 8) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment may be used as described in other current FBC product approval documents. 11) The underlayment shall not be installed over existing roof coverings. 12) Contact the manufacturer regarding specific exposure limits for each underlayment. 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. ��` ,PRY" ,IR , ��i o�••......... 9Z 2015.04.1 No 74021 3 09:06:05 -04'00' :''.• STATE OF QJ :�4", p. ��� Zachary R. Priest, P.E. ��i,FSi• R 1�•••�j���` Florida Registration No.74021 A,;G �� Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is hot owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF REPORT TBP14001.1 FL12328-R5 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. i • . , . . . . . . . . , . Gulf 'Coa R�t SUPPLY & MANUFACTURING TM GULFRHB 26 • C • • OVER • •D • . , PRODUCT APPROVAL NO. 11651.22 i.a TM Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfRibT m Roof Panel over 15/32"Plywood Florida Product Approval #11651.22 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 �+•``N�EL S�'j��,, Newberry, FL 32669 OP% �,.0ENSF tit' *: Engineer Evaluator: . No. 75,519 Dan Kuhn, P.E. #75519 . Florida Evaluation ANE ID: 10743 'A*- STATE OF :Q: 'xNFS+'��0 R41 Validator: 0itONAL EN Locke Bowden, P.E. #49704 It,,°Z2'i t% 9450 Alysbury Place °6�315 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL#11651.22 R2•JUNE 15,2015 P11,01DUCT J , REPORT. , NEERING, LLC i / o e ® ® e . o GulfC&Nt SUPPLY & MANUFACTURING TM GULFRHE GULFRIB TM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfRibTM' 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal '/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15A2" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" Maxmurn Tota Up ift ResignPressure 69.25 psf 159.2L5 psf _�v Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" �aFasfen er Pattern Spacing Design Pressure includes a Safety Factor=2.0. FL#11651.22 R2•JUNE 15,2015 PROD ® ® . ENGINEERING,KURN FLORIDA PR , , APPROVAL Gulf 'Cozi'� SUPPLY & MANUFACTURING TM GULFHHL�) 26 GLIAGE ' iTM PANEL OVER PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. FL#11651.22 R2•JUNE 15,2015 PRODUCTEVALUA10,NHPO . ENGINEERING,KUHN ulfcoat F11-01111DA PR.-O:DUCT APPROVAL G SUPPLY & MANUFACTURING TM GULFRHIE 26 GUAGE GULFRIBPANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product.in High Velocity Hurricane Zone. FL#11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION OKUHN . ENGINEEPJNG, LLC G61CoA SUPPLY & MANUFACTURING a GULFR � S OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood �B�In.gs having a Roof Mean.Height<20'-®"; Roof Slope: Pon, I 12"orida B ilding Code 2014. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING �ZONNE 1: #9-1;5X11.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 Z4 TYPE 1 ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 ��ZONE 3 #9-15x1..5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 1Z",TYPE 2 12",TYPE 2 12",TYPE 2 12",TYPE 2 1.)PANEL DESCRIPTION:GULFRIBTM' MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4"TALL. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN.75/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 zONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or ------------- ZONE l� 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be Ja less than either 4%of the minimum width of the building or 3 feet. ^ \ i 7 TYPE 1 FASTENER PATTERN `i\\\ \\ RIDGE /�� i �9° g„ y° I tPanelLa I � ` I / i/ ZONE 1 \\ \\ L Cont.Tape Seal for use on Slopes less than 3:12 I,/ (1)#&15 x 1-1/2°w/Sealer Washer Q 24.O.C.Max ------------------- EAVE TYPE 2 FASTENER PATTERN ZONE 2 GABLE ROOF { —8.5"—{2.5°{ —8.5°—{2.5°{ —6.5°—{2.5°{ —6.5° 2.5° I I I RIDGE Cont.Tape Seal for use on Slopes less than 3:12 ----- -- ------------ (1)#8-15x1-1/2'w/Sealer Washer@ 12,O.C.Max a +---------------------- a ZONE 1 I I +---------------------+ ZONE 3 EAVE FL#11651.22 R2•JUNE 15,2015 PRQDUCT .EVA'1;UAT10JN REPORT i • • 0 • • TM a1 G Ifco SUPPLY & MANUFACTURING s 4 r r r 1 H.4,y Aim- a 1 GULFnI L�:D EXPOSED SCREW METAL ROOF SYSTEM -e.4a4u.av2`,9�4.�1` s n iR s w ' ar ■: °° T GU00 : . GuIK5,as FORMERLY KNOWN AS TUFF-R16 SUPPLY & MANUFACTURING The Gulf Coast Tuff-Rib® Roofing Panel Gulf Coast Tuff-rib®panels are a strong, durable, economic, and attractive answer to ' the growing demand for metal roofing needs in Florida and southern Georgia. Extremely versatile, they are suitable for homes and " businesses as well as agricultural and utility buildings Tuff-rib®panels provide a 36-inch coverage with 3/4 inch ribs on nine-inch centers, and utilize an anti-siphoning channel to provide protection from severe weather Figure 1 The Gulf Coast Supply office(left)and manu- facturing facility. ,r wo „ conditions. Both panels and trim are fabricated using r." T� state-of-the-art computerized equipment at our facility ' near Horseshoe Beach, Florida, to assure unifor- ta 1 7t ji ,L mity and consistency in product manufacture. io N Braffiora Panels are roll-formed to the lengths specified t "` 1-7 . by customers in either Galvalume or any of 49 more than twenty colors of painted 29-gauge, l 26-gauge, and 24-gauge high-tensile metal, ,�1 1 19 Cross 51 ready for either customer pickup or on-site delivery (customers should call about Guff of neat° -��► �e� 19 � eQu�le availability of 24-gauge metal). Your Gulf Mejdco Old Coast representative is waiting to assist you 51 Ghte�fland in making the best choice for your particular Gulf oast oC4& Horseshoe roofing needs. supply%kh. Ch ` Gulf Coast's Tuff-rib®panels are 14 mlleof south Figure 2 Location of Gulf Coast Supply fabricated from AZ-50 (painted) orAZ-55 cross Cityg PP y (bare Galvalume) grade 80 coil stock(grade 50 for 24 gauge). The bare Galvalume finish is not only durable and cost effective, but offers reflectivity so valuable here in the South. The paint system ;v employed on painted products offers optimum ! exterior protection plus superior resistance to corrosion and ultraviolet radiation. Figure 3 The Tuff-rib panel I~-9 �I While bare Galvalume carries a 25-year limited coil manufacturer's finish warranty, most painted metal carries a 40-year warranty. Both painted and unpainted are of the highest known quality in the industry. Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet every need of both the do-it-yourself homeowner and the roofing contractor. A complete line of both in-stock and custom-made flashings and trims are available in all colors as.well." 1(889) a : . Gulf . FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Installation of Panels Roof Pitch Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage. Florida-Building Code allows:"a,minimum pitch of 2/12 for Tuff rib®panels as long as lap screws and sealant are applied to the laps to prevent water from siphoning over the ribs (see Fig. S on p. 4). Lap screws and sealant are optional when the pitch is 4/12 or greater(4/12 pitch means that there is 4 inches of rise for every 12 inches running horizontally). As:a general principle,the less steep the roof, and the more necessary also that sealant be used at all side-laps. Consult our representative for recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12 pitch. Roof Preparation, Oil-canning is a wave-like, rippled appearance extending up the length of the panel after it has been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped plywood,uneven trusses,poor application:of underlayment,the use of button caps with felt"paper, etc., can promote oil-canning. Care should be taken to provide a flat, uniform surface on which to attach the panels. See page 6 for more details. Roof Application Panel installation should begin'at the gable end of the roof opposite the prevailing rain-bearing wind(this will provide added assurance against wind-driven rain being forced under the laps). Measure one panel width in from the roof edge. At this point chalk a line from ridge to eave. Place the leading edge of the first panel along this line. It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frame. It.is wise to have a person at the eave and at the ridge to ensure that-the proper panel coverage is being maintained across the roof. Also be sure that the panels are properly side-lapped(see fig. 7 on page 7). In applications where end-lapping is necessary,the upper panel on the slope should lap over the panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of panel overlap. All end-lap applications should use two horizontal rows of butyl sealant tape across the panel and proper fastening to provide a maximum water seal. An overhang of 2 to 3 inches on the eave is recommended to provide a drip edge,while only 1 inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with inside closures. For maximum weather-tightness, a row of butyl tape can be applied above and beneath closure material. Trimming and Cutting Steel Panels The best device for cutting steel panels across the profile is either hand snips or a nibbler. Nibblers, and especially Carborundum blades on electric saws,however, do have a tendency to either leave hot metal particles that can bum paint surface&or.to leave rust marks on panels and trim. The same is true of any filings left,on.the roof caused by the application of screws. Care should be taken to brush all such particles from roof surfaces after application. To cut panels lengthwise: Note carefully where the panel is to be cut, and,using a straightedge, score.deeply down the length of the panel with a sharp-pointed utility knife. Folding the panel along the score:mark, and_bending back again if necessary, should produce a clean break in the panel. CAUTIONI clean all metal shavings and particles"off of roof to.avoid unsightly rust stains • . i F�R�ERLY KN��N Ag��F�R/g t 4 S'ee pe �jal o !� 2.fOy .p1 U p p�l CY S�dZng 1'�ims & MA N U xA cTU R/NG -endN'alI v } ng r f (p e Fl dewacaU � �p:E � . Roil oor a el a detail Lap screw Tras� an-� overlap App1Y sea lasfllq to lap ant l9ure.4 r.p lui b /4cation orRfunoong trl ig leg ction of that ms an �5hin9s are F�9tire 5 -d�C�C1 t alar piece on h V the. eye rY Bch 1�3 gape or caul $.. • uilding. On pitcheeet to rna of less wi���re9'uired, tape.:are s greater a'n water. lee screws the seepgs.soptiona/. than 3/12,la ghtness of applied and or amore aetaiis°nand butyl screws aGULFRIB . Gulf FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Ordering Roof Panels and Screws Care should be taken to order panels of the correct length to avoid having to make corrective measures after purchase. Panel lengths should fall 2 to.3 inches short of the ridge when a vented ridge is desired, and should extend 2 to 3 inches past the eave.to allow a sufficient drip edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of the upper portion should be ordered short to allow placement of the transition flashing(see diagram on p. 10). The Gulf Coast sales personnel are ready to:assist customers with information specific to their particular roof. Specially-washered screws applied through the flat of the metal is the most recommended method used to attachroofing panels. 1-inch screws can be used if penetration of only 3/4 inch is either necessary or desired; otherwise, 1%2`inch screws are usually recommended. 2%2 inch screws are also available, and are often used by those who adhere to through-the-rib fastening, and for ridge-cap application: See pages 6 and 7 for more information on screw spacing and ordering. Ordering and Applying Trim The most common flashing for metal roofing is the ridge cap, whichis used at the peak of a roof where two opposing roof slopes join. Other flashings include transition flashing,end wall and sidewall flashings, and.valleys(see diagram on right for application). Eave trims include gable flashing and eave drip, either of which_are often applied above fascia trim. When roof pitch exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the;roof should be mentioned when ordering _ ridge caps, endwalls, and eave drip. When,a steeper roof slope meets a lesser_ slope,both:slopes should be mentioned when ordering transition flashing. At the gable edge the use of gable trim adds to the appearance of the structure and protects the fly-rafter,and sidewall flashing is used where the side of panel butts up against an adjacent wall. In either case, the installer should be careful to seal between the gable rake or sidewall and panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip should be specified separately from that used on the drip edge when ordering. To prevent penetration of water, insects, and debris at the ridge, outside closures should be inserted between the,ridge cap and the top end of the panel. Screws are applied through-,the ridge . cap, closure, and rib in at least every other rib of the panels. At least a 11/2" (or preferably 2%2") screw should be used for attaching ridge caps. Self-drilling lap screws,can also be used to attach ridge caps. Keep Materials Dry! Paint and finishes of Gulf Coast panels and trim are designed to withstand severe rain and wet,weather:conditions.. Neither paint, galvanized, or Galvalume finishes, however,:are designed to be in continuous contact with water for long periods of time.-:Damage will result if uninstalled panels or trim are allowed to remain wet in storage. Besure to store material that will"not be installed immediately in a dry location. Wet material should:be air-dried and re-stacked if . installation is not planned right away. . . 7 / GULFRIB :: Gulf C5a FORMERLY KNOWN AS TUFF-R111 SUPPLY & MANUFACTURING Figure and Apply Screws screw urlin Spacing How to Fi g PP Y 1,2 inch._•18 inch 2.4 inch ' 0 501 270-' , 180 { 135 Gulf Coast Supply carries screws in 3 different lengths: 1 inch, 1% c 100, 540 360` i 270 inch, and 2 '/z inch. 1-inch screws will barely penetrate a 1x4,but the o '200 1080 ,720:1540 1'/z inch are the best all-purpose size. 1V2-or 2V2-inch screws are 300 1620 .1080 810 necessary for attaching ridge caps. The table on the right can be `400 2160 ; 1440',,1080 500 ;2700_ 1800 1350 used to figure approximate quantities of screws for various purlin 600: 3240i.2160''T 1620 spacings and sizes of roofs. For 2-foot spacing between rows of o ' 700 3780 '2520`� 1890 screws, multiply the total linear feet of metal times 2.7 0 8 00 1 4320 � 2880 2160 j Example: your order is 1250 feet of Tuff-rib roofing. t 900 4860 ' 3240 2430 6 .1000 5400 . 3600. _2700 1250 x 2.7 =3375 screws 110 _5940 3960 2970 3 Please confirm all estimates with your Gulf Coast representative when 1:20. 6480 1-4320 3240 i, you placed your order. Figure 6_:Tuff;rib panel screw _ . Codes allow re-roofing over shingles without the use of battens calculation chart provided the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity. Tuff-rib metal roofing can be separated from the moisture barrier by minimum, nominal 1"x3" yellow pine battens spaced on maximum 24"centers, or according to ASCE calculations where applicable. Since direct contact between pressure treated lumber and metal roofmg must be avoided in order to prevent potential corrosion, Gulf Coast Supply sells only untreated battens. CAUTION: Battens must be fastened to the roof deck with minimum#6 screws at 12" on-center, or two minimum 8d common or pneumatic nails spaced 8" on-center, or one every 4" on-center(or by applicable calculations according to ASCE 7-98). Battens.must be installed to support the entire width and length of ridge, eave,hip,valley, and gable-end trims. For solid decking, at least 15/32-iuch structural plywood supported on rafters at a maximum of 24" on center is required. . If care is taken, metal roofing application can be aided by pre-drilling panels, allowing screws to go quickly and accurately into the desired spacing. Pre-drilling will work provided that pilot holes are placed accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured. For panel lap details, see Figure 5 on page 4. Gulf Coast Policies Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales department for details. Sales tax All orders picked up at Gulf Coast Supply, and all orders delivered within the state of Florida, are subject to state sales tax. Tax exemptions should be verified prior to delivery or customer pickup. Warrantied products A 40 year warranty applies to most material*manufactured from painted coil stock,and a 25-year warranty to Galvalume material. Ask for details. Indemnity All prices and designs are subject to change.without notice Disclaimer While we have made every attempt at accuracy in this manual,we are not responsible for typographic, printing,or technical errors. Oil Canning--a repeating,wave-like appearance in the length of the panel—is.a common and often unavoidable phenomenon in metal panels like Tuff-rib roofing that have large,flat areas within the panel. It is therefore not a defect,nor a cause for rejection. See.p. 3 for details on how to avoid oil-canning. Return policy 'All panel orders and special order(non-stock);trim are considered the property of the customer and non-refundable once they are manufactured. Standard trim and accessories are refundable providing they are returned in a clean,resalable condition. Restocking charges will apply to any items at the discretion of the Gulf Coast representative. GULFRIB" DETAIL e e FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Gulf Coast Tuff-Rib® Roofing Panels SECTION PROPERTIES ALLOWABLE LOADS(PSF) Fb., Live Load' Lige Load Ixlrr.Sx In.•U In.Sx in Wind Load . Stress (Deflection -Panei Fy ickne KSI Weight Girth (Stress) ) Gauge KSI . .-.An.- Pos. Neg. PSF ;In',,` .Positive ; Negative2;�.2'6 3' 3 6 4'� 2' 2'6 3 ,-6' 4- `2- 2-6- 3 '3-6' 4" Bending'} _ Bending ,, 26 ga. 80 .0187 36 36 .91 42 0288.0482 .0288.1892 170 109 76 56 42 128 82 57 42 32 102 52 30 19 13 29 ga. 80 .0142 36 36 .69 40.875 0232.0374.0232.1786 133 85 59 43133 1100­64 44 33 25 82 42 25 15 10 Fastening Schedule for Various Wind Speeds Wind Speed Zone 110 MPH 120 MPH 130 MPH 140 MPH Roof Fastener OnCenter OnCenter OnCenter OnCenter Zone Type Fastener Size Attaching to: Spacing Spacing Spacing Spacing Wo 1x4 wood Zone 1 or . '#9A5 x 1'/� 24" : 24" 24" 24" WoodZac® _,:purl'IRs__:_ - Wood rip® Zone 2 WoodZac® #9-15 x 1'/z 1 pu wood 24" 24" 24" . 12" Woodgrip. 1x4 wood 4!r 2.. 2.. 2.. Zone.3,.WoodZac® #9-15 x-1% purlins 2 Zone 2 -� a Eave Roof Zones ;........................... ;... Each "zone" of the roof has its own screw requirements. Dimension a is defined as 10%of the minimum width of the building, or 40% of the mean ............................. .......................................... ... height of the roof, whichever is ________________ a smaller; however,a cannot be less Ridge-------------- than either 4% of the minimum width . ........................................................................... of the building, or 3 feet. Zone 1 Gable .......................................... Ridge � k Eave A x Zone 3 rlter On OSPa�in aq 'il. 3�f�fJ �f f t'fiZZ� J <. ,.�.►.�-e•:=...gra;ve.. 'F -.�, .F-. �,: �y* f �,4y 1 .:. Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, EaVe and on the overlap side of the panel lap. 1(1888) 1 . . 00, :Tm . Gulf CoaA. FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING ` ® Eave Drip & Fascia FHA Style ED-3 Style 2 3/8 r Eave drip Eave drip. Y 7/16' w—b--►i R For custom eave drip, specify the Eave drip with fascia and inside closureEave drip a amount of the eave that will be Figure 8 Eave drip and fascia give a finished look along the drip covered(dimension"a"), and, for eave of the house, as well as providing protection for the steeper roofs, specify pitch . If materials they cover.The eave drip should completely cover the Fascia a fascia is desired,be sure that the top edge of the fascia. Inside closures,which seal off the open 1 dimension you order will be ribs of the panels,are optional: hidden by the eave drip. Summary of Stock Trims and Flashings item special order information Ridge caps(RC-2) specify,pitch if less than,,3/12 or greater than 6/12:' Also available in arger widths. Closures recommended: Eave drip (FHA,ED-3) 2 common styles. FHA style is pre-pitched for 3/12 to 6/12 roofs. For appearance or ease of application, order by either specific pitch or as gable trim (901). Gable flashings Residential(EF-1),large (GR-2), and small(GR-1) rakes available..°Use butyl sealant between rake and panel: Valleys (PV-1) specify.pitch if greater than 7/12. Seal with universal foam closure material..Open-hemmed valleys (PV-2). aid water-tightness. Sidewall (SW-1) Use butyl sealant between sidewall flashing and panel. Endwall (EW-1) Specify pitch if greater than 5/12.-Seal with'outside closures. Transition flashing Specify pitches of-both roofs. Seal lower slope,using outside closures and, if desired,inside closures on upper slope; ■. ■ i l . GuZlf FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Ridge Cap The Ridge Cap is used to seal the point at which two upward slopes meet. This can be both along the ridge of the roof as well as a covering for a hip. Either woodgrip or self-drilling lap TEK screws are applied through the ribs of the metal. Since debris, insects, and blowing rain can find easy access under the ridge cap, closures are required to either completely or partially seal the opening. `:'` , ' Closures under ridge caps come in 3 types: solid,vented,and hip tape. Figure 9 Ridge cap showing outside closure (left) and profile vent Solid closures ("Outside Closures") are (right). the same width as the panels. They lock together in a row placed directly ; under the screws that attach the ridge cap, and form a solid,water-tight, F air-tight barrier. Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water- retardant, insect resistant barrier that allows hot air to escape from the = , attic,and is superior to many more elaborate and expensive vent systems. Any length may be ordered. < Hip closure tape(Peel and Seal)is a sticky, adhesive-backed metallic tape that seals the hip roof. It is 6 inches wide and comes in 33%2 foot rolls. Because it must be conformed to the rise and fall of the panel ridges, approximately 10% extra may be needed beyond the length of the hip being covered. Figure 10 Pipe Boots provide a water-tight. seal around roof Outside Profile Vent® vents and come in a variety of closure 6 or Versa-Vent® sizes. They.seal with caulk and conform to the shape of the panel ribs. pane ,. `Lap or 2'/z"Woodgrip�► screw required RC-2 Standard 12-inch Ridge Caps are strong,economical and adequate for most of your roofing needs a� 6"� RC-2 style over-sized ridge caps are available with 18-inch coverage,or as a custom trim RC-1 style 124nch Ridge Caps item in total widths(2 times"a")of l4-, l6-, l8-,20_, are also available in custom widths 22-,and 24-inch 000, LF RIB MANUAL GUIKSayt FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING � g . k End-Wall Flashing End-wall flashing is applied where the upward slope of a roof meets a wall. The wall side of the flashing can be covered with siding or w: .._ counter-flashing, and outside closures are X. necessary to seal caulk(Solar Seah between t h e recommended) caulk edge(order EW--1C) flashing and the ' - (used if endwall not panel.Roof slope ' 3 covered by siding) s h o u l d be Zo . r mentioned.if roof -- %►, exceeds 5/12 pitch. Figure 11 As with the ridge cap, the ENDWALL° FLASHING above is sealed using outside closures. pad EW-1 Stepped Use EW-2 hemmed endwall when cornering endwalls with sidewall b Endwall EW-2 Hemmed flashing,such as with dormers or chimneys. b Endwall For custom end-walls, sped roofpitch and dimensions"a"and"b". a a_4i/11 b=31 Transition Flashing loo, The TRANSITION FLASHING .prevents leakage at the point where two different roof pitches meet. It must be sealed on the lower side with outside closures,and can be sealed underneath the upper panels with inside closures. The similar GAMBREL y . FLASHING is used where the lower pitch is steeper than the upper. Transition Flashing closure 14--a-'r/ Figure 12 The transition flashing (above) and the GF-1 gambrel flashing (right) provide a For custom transition flashing specify the pitches continuous drainage where two of the two roof slopes and,if necessary,dimensions slopes meet. Both seal 'with ' "a"and"b". outside closures on the lower side. ZIP. .: . IfCoaYt ' 1 FORMERLY KNOWN AS TUFF-RIB SUPPLY & M A N U F A C T U R I N G Gable Flashing Poo.' f 311 Bulyl tape 3/4" 311 I EF-1 style Custom trim—specify a custom R length for a or b. r—a-01 Standard dimensions — a=3" View of EF-1 gable trim(fascia board removed b=3" Figure 13 Gable flashing is used to trim the edge of the roofing panel at the gable end of the roof. It should match GR-1 style the eave drip that extends along the drip edge of the roof. If Custom.trim—specify a custom the panel is-allowed to hang over the.gable end,eave drip length for a or b. b can be used instead. Butyl tape between the trim and Standard dimensions a= 2 fig" panel eliminates leaks. V-24811 Sid - e wall Flashing caulk (Solar Sea)p recommended) caulk edge (order SW-1C) (used if sidewall not covered by siding) ,3n n —3 --� Butyl tape 3/4' }} iTrtew O Standard sidew'all trim , Figure 14 Sidewall flashing is applied when the side of the SW-1 roof butts up against an adjacent wall. The wall-side of the ' - flashing can either be covered over with siding or sealed Custom trim=specify a custom with caulk (order SW-1C). Butyl tape should be>applied length for a or b:` 1 �� where the"foot"of the flashing attaches to the roof. Standard dimensions — a=3" b=3" 1(888) 393-0335 - FAX(352)498-7852 -www.GulfCoastSupply.com .. 000, i LFRiB GUlf0. .1 FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Preformed Valley Install panels 4 to 6" from diverter ` 0 41 9��i► ° o PV-1 style a ° PV:2 style - Two basic styles of valley are available. For custom valleys, specify dimension"'a" Figure 15 Pre-formed valleys use a diverterto preventwater from rushing under panels on the opposite side, while meanwhile channeling water off the roof. Expanding foam closures are often used to assure a good seal. Gulf Coast Tuff-Rib® Siding r- GR-2 Rake & Corner' 13 Drip Cap Sliding - Door us d`e Corner utter ' J-Channel ` - 9 % t� TC1 Track; w= Base Coved(P �l'S) (p. 14) Figure 16 Common trims associated with Tuff-rib roofing panels www.GulfCoastSupply.com 12. B m DETAIL MANUAL Gulf 1� FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING GR-2 Outside Corner Polo. The GR-2 Rake and Comer can be used as a gable trim or a comer for metal-sided buildings. As an alternative, the smaller EF-1 or the GR-1 (both on p. 11)can also used as gable rakes,and the PC-5(below)or the GR-1 as comers. ,� ;` '� 2 Customizing rakes or comers is often necessary due to their landing on a panel rib. Both the GR-2 ' and the IS.2 can be ordered as custom trim items by specifying custom dimensions "a" or"b". Be fi sure to take into account the W" h x head space when figuring custom dimensions. � f � {�3'-�j r aner The PC-5 flat corner P. works best on smaller Figure 17 When used as corner trim,the GR-2 straddles the ribs 3" / structures, and where of the panels where they meet at the corner of the building. The `�!, . Tuff-Rib outside comer also serves as a gable rake(see below). the panels are running .outside horizontally. It can be The inside corner (IS-2) has similar dimensions but with a }' 'closure sealed with outside reverse middle bend. closures. as PC-5 WNW—& goo GR-2 Gable Rake 611 _ - —45/8 1 3/411 11I a � I � 45/811 GR-2 b b IS-2 Figure 18 When used as a gable rake,the GR-2 runs parallel to the ribs of 14—a--►q the roof panel, and is attached with screws running through theribs of upright siding. As with the EF-1 residential rake, the roof side can be sealed with butyl sealant. 1(888) 393-033:5 - FAX(1352)498-7852 .Wvvvv.Gu1fCoastSupp1y.com i M[f2j/) B Tm DETAIL MANUALGulf fORMFRLY KNOWN AS TUFF-RIR SUPPLY & MANUFACTURING _: . Drip Cap and C, 4 J-Channel DC-1 Drip cap 10. rip cap m 2'V2 ``. - ��chant 91 capping the panel end c< JC-1 I J-channel Figure 19 The drip cap is commonly used to trim out the bottoms of panels; over doorways and windows, and occasionally takes the place of base drip.;' I� J-channel is used to cap raw panel edges where run-off is not a problem;and panel 7/8 is most commonly used to trim around the bottom,sides,and occasionally the top of windows and doors,and also to cap the top sides of skirting. �--a-2 '/4"—► capping the panel edge Base Drip -BD-1: . . 11/4" Base,drip Figure 20 Base drip seals off the bottoms of panels at the floor level,where it helps to prevent the entrance of rodents and insects,as well as a base for the setting of panels. lGULFRIBTm DETAIL MANUALGulf FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Gutters ► 0-00000� Gulf Coast Supply produces 29-, 26-, and 24- gauge gutters in either 5-or 6-inch widths(depth is approximately equal to width). All gutters should be ordered specific to the pitch of the roof. Downspouts are available in 3"x4" (for 5- inch gutters) and 4"x4" (for larger gutters). End caps should.be ordered at the same time as the gutters to assure a custom fit. Special hangers fit into the panel rib and under the gutter lip. Panels should extend no:more than 1" to 1'/z" inches beyond the eave on which gutters are planned. lap screws ye Figure 29 Exposed view of gutter showing gutter hanger placement, �--5 or 6-'—► IN °o downspouts,and end caps Hangers employ lap screws,and end caps are best attached with rivets. Gutter:hangers fit inside panel rib and under lip o Outer Inner Outer Inner iter of gutter(apply at least one per panel)and are Inner and outer gutter sections(marked'7"and "O') Attached-with lap screws alternate'along the eave to assure ease of application and or`rivets. gutter appearance. Downspout Downspouls in excess of 10 feet in length must be made in 2 sections. T". ; t Track Covers, Door header;-. TC-1 3 sliding door r 3/4 , ► track cover n 2Y211 k 5" f Figure"22 Sliding door track covers fit.over,the door track and Door under the panels to hide the track,assure a neat appearance,and shed water over the door. 11(088) 393-0335 FAX(352)498-7852 www.GulfCoastSupply.com 15 000, GULF RIB , 1. Gulf N,-, FORMERLY KNOWN AS TUFF-RIR SUPPLY & MANUFACTURING Ridge caps(pg. 9) Eave drip(pg. 8) Valleys(pg. 12) Gable rakes(pg. 11) Sidewalls(pg. 11) Endwalls(pg.10) 1 Transition&gambrel Door&window ` flashings (pg. 10) Corner trims(pg. 13) trims(pg. 14) Base drip(pg. 14) Pipe Boot(pg. 11) Electrical Boot 'r Inside Closures M r ) ® Expanding, Outside Closures Versa-Vent Profile Vent Foam Peel and Seal Touch-up Paint zv Fc r S/D EK Lan TEK Foil-backed thermal Butyl Tape Solar Seal® barrier insulation Woodgrip Screws TEK screws ZAC screws Guide to Misc. Accessories item application pipe boot Fits over vent and heat pipes. Available also in heat-resistant boots. _electrical boot Fits aroundpipesfwith inaccessible tops (such as,weatherh_ea_ds). _ outside closures Required to seal under ridge caps and transition and endwall flashings. inside closures _Seals under panels, particularly on the-eave. _ _.L........,,... -,..`l._ .._.. .._.__ ._..._......_-..Y_.— ._..__.�_.......,—.._ ._..—...ti—._..—.._ _ dam.-.... _..— Proflle Vent®Versa-Vent® Vented closure material surpassing many other venting systems. expanding foam - C®mpressed-'adhesive fo - 'expands to-seal between-valleys and=panels_=, Peel and Seal® Seals hips under hip caps. Also, a general purpose sealing tape(6" wide). touch up paint__ u .Hides scratches and marsencountered in installation Over 20;colors butyl tape_ _ _ General purpose low-cost sealant, used on panel laps and under trim. - Solar Seal®, _tiA_superior general purpose caulk for'all ioints. Matches panel colors Low profile insulation .Greatly reduces radiant heat when installed under panels. �— V6Toodgrip screws .-Used in all applications attaching metal to wood. 111,- 1V2", X21/" sizes J .ter TEK screws Self-drilling TEK screws for metal purlins. Lap TEK screws draw together Joints and attach'trim. ZAC® screws ; `.`Lifetime" screws; 11/2",'21/2", threaded for wood; self-drilling available.