HomeMy WebLinkAboutEngineering MULE-HIDE TPO ROOF APLICATION SYSTEM FL 12772.1
Q �
� w � M
1%ROOF SLOPE(EXISTING)
1/4"DENS DECK ATTACHED SIMULTANEOUSLY WITH TPO O a U
1.5"POLY ISO ISULATION(4 FASTENERS PER 4'x8'BOARD IN THE FIELD AND WITH 8 IN THE PERIMETER AND CORNER ZONE) a
z
�60mil TPO(MECH FASTENING-SEE SCHEDULE BELOW) 0
400
0
� EXISTING 5/8"PLYWOOD SHEATHING
ev
Ll J N
v TPO FASTENING SCHEDULE ALLOWABLE DP FASTENER: OMG XHD FASTENERS w a
wWITH OMG 2-3/8"BARBED U w
FIELD : 6" OC @ 5.5"LAP, 1 ROW @ 72" OC +/- 67.5 psf XHD PLATES W w v
EDGE: 6" OC @ 5.5"LAP' 1 ROWS @ 36" OC +/- 135 psf
SEAMS 1.5"WIDE E~ Ga
CORNER: 6" OC @ 5.5"LAP, 1 ROWS @ 36"OC +/- 135 psf HEAT WELDED w
Q � w
H o0
DESIGN PRESSURES FOR Vasd= 160 MPH,EXPOSURE C
,Somme.
•.• A• B�••. Lildon Engineering Company, Inc.
U FIELD : -35.8 psf ROOF HEIGHT=20 ft ;' �•• •'•'•\GENSF0• '.� 920 Sunset Shores Dr.
�� •'C Minneola, Florida 34715
PERIMETER: -60.0 psf3 X352)394-2590 Ph.&FAX
Na, 5258 *; cert. o uth. 2898
U— CORNER: -90.3 psf e �`
STATE OF :
* DERIVED FROM RAS 128 USING ASCE 7-10 �••FSSIONENG
••• AI-••
Namesgust 26,2015
Wayne . Block, PE#52583
Appt: Sales Contact: 8104 lakeland bled
Job# FORT PIERCE, FL 34951
Miami/Dade Field Inspector: RECEIV�
�DAUG271013
Area DiRhn n .R,
Total Area: 3,658 sq ft, 6 facets
There are 398 sq ft of roof with a pitch below 3/12 (See Gray facets on Pitch Diagram)
374
r
104 104
z^
1586
1092
398
A
- N � s
Note: This diagram shows the square feet of each roof facet (rounded to the nearest foot). The total
area in square feet, at the top of this page, is based on the non-rounded values of each roof
facet(rounded to the nearest square foot being totaled).
r
HOME IMPROVEMENT CONTRACT
PLEASE READ THIS CONTRACT
ROOFING SPECIFICATION SHEET
DESCRIPTION OF WORK
Customer Name: Mr.Kaus bywaletz Date: 8/14/2015
Branch Name: Miami Job#: 8476469
Sales Consultant: Paul F Mclean
I LINE#"1
Hurricane Mitigation=No, Flat Product=TPO-60 mil, Flat Material Removal
Roof Color=White,Taper System=No,Standard 2 Year, Flat Roof Decking Replacement=No
Atlas GlassMaster,Atlas GlassMaster=Silver White
Number of Squares(excluding Low Slope)=34.33,
Number of Flat Roof Squares=6 Flashing
Misc Linear Ft of Drip Edge to be Installed=345,Color of Drip
Off Ridge Vent=No, Replace Fascia=No, Hurricane Edge to be Installed=White,Linear Ft Flashing to be
Mitigation Inspection=No Installed=Yes, Linear Ft Base Flashing to be Installed=
60, Color of Flashing to be Installed=White, Chimney
Flashing=Yes, Chimneys Requiring New Flashing=1,
Color of Chimney Flashing to be Installed=White
Pricing Includes:
Base Flashing
Chimney Flashing
Drip Edge-in 1 Oft Sgmts
Shingle Removal and Application
Flat Roof
SPECIAL CONSIDERATIONS
y
Homeowner comments:CUST IS HARD OF HEARING,TALKS VERY LOUD,ISNT YELLING..Cust number is alt...primary is his
contact due to hearing
PRE JISTING GONDITtONS
ADDIT ONAL CHARGES
If rotted or damaged wood is discovered AFTER removing the existing roofing,or could not be identified at the time of sale,there will
be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per linear ft.of dimensional lumber for decking.
If additional layers of roofing are discovered AFTER removing the first layer,or could not be identified at the time of sale,there will be
an additional charge per square to remove each additional layer based on product to be removed:
$ 21 for composition shingles,$ 55 for wood shingles.Low or flat roofs will be priced on a per job basis based on
complexity.
06117/14-SA Page 7 of 9