Loading...
HomeMy WebLinkAboutEngineering MULE-HIDE TPO ROOF APLICATION SYSTEM FL 12772.1 Q � � w � M 1%ROOF SLOPE(EXISTING) 1/4"DENS DECK ATTACHED SIMULTANEOUSLY WITH TPO O a U 1.5"POLY ISO ISULATION(4 FASTENERS PER 4'x8'BOARD IN THE FIELD AND WITH 8 IN THE PERIMETER AND CORNER ZONE) a z �60mil TPO(MECH FASTENING-SEE SCHEDULE BELOW) 0 400 0 � EXISTING 5/8"PLYWOOD SHEATHING ev Ll J N v TPO FASTENING SCHEDULE ALLOWABLE DP FASTENER: OMG XHD FASTENERS w a wWITH OMG 2-3/8"BARBED U w FIELD : 6" OC @ 5.5"LAP, 1 ROW @ 72" OC +/- 67.5 psf XHD PLATES W w v EDGE: 6" OC @ 5.5"LAP' 1 ROWS @ 36" OC +/- 135 psf SEAMS 1.5"WIDE E~ Ga CORNER: 6" OC @ 5.5"LAP, 1 ROWS @ 36"OC +/- 135 psf HEAT WELDED w Q � w H o0 DESIGN PRESSURES FOR Vasd= 160 MPH,EXPOSURE C ,Somme. •.• A• B�••. Lildon Engineering Company, Inc. U FIELD : -35.8 psf ROOF HEIGHT=20 ft ;' �•• •'•'•\GENSF0• '.� 920 Sunset Shores Dr. �� •'C Minneola, Florida 34715 PERIMETER: -60.0 psf3 X352)394-2590 Ph.&FAX Na, 5258 *; cert. o uth. 2898 U— CORNER: -90.3 psf e �` STATE OF : * DERIVED FROM RAS 128 USING ASCE 7-10 �••FSSIONENG ••• AI-•• Namesgust 26,2015 Wayne . Block, PE#52583 Appt: Sales Contact: 8104 lakeland bled Job# FORT PIERCE, FL 34951 Miami/Dade Field Inspector: RECEIV� �DAUG271013 Area DiRhn n .R, Total Area: 3,658 sq ft, 6 facets There are 398 sq ft of roof with a pitch below 3/12 (See Gray facets on Pitch Diagram) 374 r 104 104 z^ 1586 1092 398 A - N � s Note: This diagram shows the square feet of each roof facet (rounded to the nearest foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet(rounded to the nearest square foot being totaled). r HOME IMPROVEMENT CONTRACT PLEASE READ THIS CONTRACT ROOFING SPECIFICATION SHEET DESCRIPTION OF WORK Customer Name: Mr.Kaus bywaletz Date: 8/14/2015 Branch Name: Miami Job#: 8476469 Sales Consultant: Paul F Mclean I LINE#"1 Hurricane Mitigation=No, Flat Product=TPO-60 mil, Flat Material Removal Roof Color=White,Taper System=No,Standard 2 Year, Flat Roof Decking Replacement=No Atlas GlassMaster,Atlas GlassMaster=Silver White Number of Squares(excluding Low Slope)=34.33, Number of Flat Roof Squares=6 Flashing Misc Linear Ft of Drip Edge to be Installed=345,Color of Drip Off Ridge Vent=No, Replace Fascia=No, Hurricane Edge to be Installed=White,Linear Ft Flashing to be Mitigation Inspection=No Installed=Yes, Linear Ft Base Flashing to be Installed= 60, Color of Flashing to be Installed=White, Chimney Flashing=Yes, Chimneys Requiring New Flashing=1, Color of Chimney Flashing to be Installed=White Pricing Includes: Base Flashing Chimney Flashing Drip Edge-in 1 Oft Sgmts Shingle Removal and Application Flat Roof SPECIAL CONSIDERATIONS y Homeowner comments:CUST IS HARD OF HEARING,TALKS VERY LOUD,ISNT YELLING..Cust number is alt...primary is his contact due to hearing PRE JISTING GONDITtONS ADDIT ONAL CHARGES If rotted or damaged wood is discovered AFTER removing the existing roofing,or could not be identified at the time of sale,there will be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per linear ft.of dimensional lumber for decking. If additional layers of roofing are discovered AFTER removing the first layer,or could not be identified at the time of sale,there will be an additional charge per square to remove each additional layer based on product to be removed: $ 21 for composition shingles,$ 55 for wood shingles.Low or flat roofs will be priced on a per job basis based on complexity. 06117/14-SA Page 7 of 9