HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
u u a J
G
,i
jr::( SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts i Publications j FBC Staff ; BCIS Site Map 5I Links Search
Business'
Professibhal goProduct Approval
USER:Public User
der
g i tk"n
���yy��yyyy -Product Approval Menu>Product or Application Search>Aoolication List>Application Detail
FL#
Application Type
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments Public Comment 1. Gascon-Certification is not inclusive of fin mounted
units and installation instructions show fin mounts. (See sheets 2 and
6.)7/27/15-rb
Archived
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft. Myers, FL 33912
(800)432-2204 Ext 4314
thoard@easternmetal.com
Authorized Signature Timothy Hoard
thoard@easternmetal.com
Technical Representative Timothy J. Hoard
Address/Phone/Email 10030 Bavaria Road
Fort Myers,FL 33913
(800)432-2204 Ext 4314
thoard@easternmetal.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute,
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996 2009
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8... 8/31/2015
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option A
Date Submitted 05/18/2015
Date Validated 07/02/2015
Date Pending FBC Approval
Date Approved 07/09/2015
Date Revised 08/28/2015
Summary of Products
FL# Model,Number or Name Description
17759.1 Series 623 HVHZ Vinyl Sliding Glass Series 623 HVHZ Vinyl Sliding Glass Door
Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17759 RO C CAC N1012526-R2-sioned.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 06/30/2018
Design Pressure:+65/-65 Installation Instructions
Other:Approved configurations: OXO,OXXO FL17759 RO II 08-02695.Dclf
Verified By: Luis R. Lomas,P.E.62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17759 RO AE 13-0328.09 Dupont SentryGlas.pdf
1'1.177.59 RO AE 13-0328.09-COMP.pdf
FL17759..RO AE 51_3471..,ff
FL17759 RO AE Deceuninck PVC NOA 13-1203.02.PDF
Created by Independent Third Party: Yes
back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
I�a",� ' I
six uritc:,:::'rit ic's,
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8... 8/31/2015
REVISIONS
REV DESCRIPTION DATE I APPROVED
NOTES: 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" CRETE FLEX WITH
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE INSTALLATION DETAILS.
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #12 SMS OR SELF
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY DETAILS.
8. ALL FASTENERS TO BE CORROSION RESISTANT.
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY 1
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE'WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
AMINIMUM SPECIFIC GRAVITY OF G=0.42
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF . WOOD
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH
OF 3,192 PSI.
THE ARCHITECT OR ENGINEER OF RECORD. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER).
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM
PROVIDED. 20.APPROVED CONFIGURATIONS: 0X0 AND OXXO.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #12 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/4" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGNED:04/17/2015
�F EASTERN ARCRITECTURAL SYSTEMS 1511+'1/
c���� r� FASTERNMETAL SYPPLY \\\\\� R, Cb/�I��/
® 1-1 DOMESTICAVE \ • A • /
/A FORTMYERS.F-12 \ • • /
TABLE OF CONTENTS 623 HVHZ PD W/IMPACT BRACKETS HIGH PRESSURE *• py§1251
VINYL EQUAL LEG FRAME SLIDING GLASS DOOR _9 (( frr€ . �_
SHEET N0. DESCRIPTION NOTES `-p, TAT OF
i0. W�
1 NOTES DRAWN: DWG NO. REV ���N ZORIDt-
2 ELEVATION
3 6 INSTALLATION DETAILS NAE NTS DATE 04/16/15 08-02695SH SHEET 6 ///�S1OilIAi1� \\\\
REVISIONS
REV DESCRIPTION DATE APPROVED
192" FRAME WIDTH 192" FRAME WIDTH
6" MAX I I—� 12" MAX O.C. -I 6" MAX 6" MAX - � � 12" MAX O.C. 6" MAX
6" MAX 6" MAX
12 1-2—
T—
MAX
�
MAX O.C. MAX O.C.
T—
o x x o o x x o
96" <= a
MAX 96
FRAME MAX
HEIGHT FRAME
HEIGHT
J
T6" MAX 6" MAX
I }
625.620 PD VINYL EQUAL LEG FRAME SLIDING GLASS DOOR 625.620 PD VINYL EQUAL LEG FRAME SLIDING GLASS DOOR
EXTERIOR VIEW EXTERIOR VIEW
FRAME INSTALLATION FIN INSTALLATION
DESIGN PRESSURE RATING IMPACTRATING 3/16" TEMP. 1 INTERIOR
t65.0PSF LARGE AND SMALL 1/8" ANN.
MISSILE IMPACT EXTERIOR .090" SG BY DUPONT
MISSILE LEVEL D,WIND ZONE 4,AND HVHZ 1/8" ANN.
NOTES:
1. MAXIMUM PANEL SIZE: 49 3/16" X 93 1/2" DURASEAL/QUANEX
2. MAXIMUM D.L.O.: 40 3/4" X 85" SPACER
3. (4) 1" X 1/4" WEEP NOTCHES AT EACH CORNER OF EXTERIOR SILL AND INTERIOR TRACK LEG. 5/8" BITE SILICONE
SIKAFLEX 552
} Q SETTING BLOCK
GLAZING DETAIL
HARDWARE SCHEDULE SIGNED:04/17/2015
A. (4)STEEL FRONT ADJUSTABLE TANDEM ROLLER AT EACH OPERABLE PANEL BOTTOM RAIL CORNER �rrq�i y�p EASTERNARCMTEC0RALSv5TEM5 111111!
B. (2)INSIDE/OUTSIDE PULL HANDLE AT LOCK STILE OF OPERABLE PANELS 1°�*� Easte!!1 "'ERNMIETALSYPPLv \\\\\S R. 'LbA7//Xj
C. (1)GEMINI II L0CK WITH 24SOTRIMPLATE 381 4"FROM BOTTOM PANELAT LOCK STILE ■ 16-00MESTICAVE \
FORT MYERS.FL-Q
D. (1)STEEL KEEPER(GEMINI 1")381/4"FROM BOTTOM PANELAT LATCH STILE E�S�9if�
E. (1)ALUMINUM REINFORCEMENT SHAPED(10300151)AT EACH FIXED PANEL INTERLOCK 6231HVHZ PD W/IMPACT BRACKETS HIGH PRESSURE fit• 0 5
VINYL EQUAL LEG FRAME SLIDING GLASS DOOR f �
F. (ALUMINUM SQUARE TUBE REINFORCEMENT(10300151-A)AT EACH OPERABLE PANEL VERTICAL INTERLOCK RAIL =O
G. (1)FREE FLOATING ALUMINUM REINFORCEMENT(1030D150)ATEACH FIXED PANELJAMB STILE AND ACTIVE PANELLOCKSTILE ELEVATIONS mgt, TAT OF rL�
H. (1)ALUMINUM RAIL INSERT REINFORCEMENT(10300152)AT EACH OPERABLE PANEL BOTTOM RAIL DRAWN: DWG N0. REV ��Fs�,CO :G\�\
I. (1)ALUMINUM"L"ANGLE(EMS 11-63-275)AT FRAME SILL SCALE DATE 08 02695 - A`1t��`\\\
J. (4)NYLON IMPACT BRACKETS(011HO55-D)ONE AT EACH OPERABLE PANEL INTERLOCK STILE,TOP/BOTTOM RAIL INTERFACE NTS 04/16/15 -riTEE12 OF 6
2 1/2" MIN. REVISIONS
EDGE DISTANCE REV DESCRIPTION DATE APPROVED
CONCRETE/MASONRY °
BY OTHERS a
da ,
a ° 1 1/4° MIN. .
OPTIONAL 1X BUCK ° ° ° ° ° Q ° EMBEDMENT
SEE NOTES 3 - 7 1 1/4" MIN.
SHEET 1 ' EMBEDMENT
BACKER ROD
& APPROVED MAX. 1/4" MAX.
MIN.
OD O
/
SEALANT � � SHIM SPACE 2 1/2 e° r SHIM SPACE
❑
EDGE
❑ ❑
DISTANCE ° o
`
1/4" CRETE-FLEX INTERIOR
1/4" CRETE-FLEX Op
E30T 11 Uk °
D D ° ❑ c:J
EXTERIOR INTERIOR a
OPTIONAL 1X BUCK �
fl fl SEE NOTES 3 7 °
SHEET 1
❑ BACKER ROD EXTERIOR
CONCRETE MASONRY & APPROVED
/ SEALANT
BY OTHERS
1/4" CRETE-FLEX JAMB INSTALLATION DETAIL
CONCRETE/MASONRY INSTALLATION
BACKER ROD ❑
& APPROVED 0
SEALANT
1/4" MAX. NOTES:
OPTIONAL IX BUCK
SEE NOTE 3 - 7 0 ❑ r SHIM SPACE 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS,
SHEET 1 + NOT SHOWN FOR CLARITY.
} 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
CONCRETE/MASONRY SIGNED:04/17/2015
BY OTHERS ° ° °
e
1 1/4" MIN. EAsrEftNaftDl SI
NOALsysreMs 111111!
EMBEDMENT eqb. ADINSIONOF
Eastern EASTERN METAL SYPPLY \�� R. L0
STIC AVE \\\\ ' •
I—I DOME ��
8 !S. FORT MYEftS fL JJ91] \ r E tt /
2 1/2" MIN. 623 HVHZ PD W/IMPACT BRACKETS HIGH PRESSURE _�c• 0 51 =
EDGE DISTANCE VINYL EQUAL LEG FRAME SLIDING GLASS DOOR t°
INSTALLATION DETAILS �x1, 7A7 OF
VERTICAL CROSS SECTION �0�.• P ,kid
CONCRETE/MASONRY INSTALLATION DRAWN: DWG ND. REV //F�,.
SCALE DATE 08-02695
8 50 2695 - �i7i/S�ONAl1.la���\
NTS 04/16/15 5 OF 6