HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page I of
N=
. aCIS dame tog to User Registration fiat Topics Submit Suitharge Stals h Falls Publication% I tic Star# RCIS Sde 11ua i mti,% San i n
I Pof essioI 1a) «� users PubbADprovai
Professional
c User
P"SLStktiIcyt:M"'.0 r tlSxtjl' 1 1, Q11L121W,`y^1 moi`>A"'ll",t ytil k r Application Detail
FL fr FL10674•RIO
Application Type �.— Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7629
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler '
greg.keeier@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email I Owens Corning PKWY
Toledo,OH 43659
(419.)376-8360
mel,sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
CategoryRoofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flur,da
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity .-- 0CTCC"--
Quality Assurance Contract Expiration Date 08/20/2017
Validated By '—" JOfiii .Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R10 Cts( 2015 01 COI Niyaijile 1.dl
Referenced Standard and Year(of Standard) SbuWard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
https 1/floridabutldtng.orgtpr/pr_Lipp_dtl_aspx?parani=wGEVXOwtDgtBNbEY5V`Io2boOT°o2b6w7ahReglC08ucR6ixEAoiMeKNJKxMw%3d%3d July 1,201 S
Florida Building Code Online Plge 2 012
Product Approval Method Method 1 Option D
Date Submitted 04122/2035
Date Validated 04/23/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Summary of products
FL# Model,Number or Name Description
I0674.1 Owens Corning Asphalt Rooting 3-tab,4-tab,5-tab,laminated,starter and hip&ridge.shingles
Shingles and Starters
e
Limits of Use Installation Instructions
Approved for use in HVHZ:No f 10674 Ii1OJL.;!LtLS_ ';ff:tin( .l It S?S _E•5l:r�LT.
Approved for use outside HVHZ:Yes 5►.t1Et1 EL10�7-_i�r1¢yjljf
Impact Resistant:N/A Verified By:Robert J.M.Nieminen PE-54166
Design Pressure:N/A Created by independent Third Party: Yes
Other:Refer to ER,Section S. I Evaluation Reports
Ft 1OG74 R10 nE �Ql.;�..,( LC1Al EEi U4 -HAL I
5L1ItLCi FL.5 Et_1.QfzL't_[UID..01
I Created by Independent Third Party:Yes
fan w 111•-;;tQ4n North tonne.•Ct rtY•l Taftaitayynr•F, l2ta4 pjfu_ne;�L••iH
the Stoto of Florida is an A4,1EEO employer.t=-wight aft 7.7ni's ctat of nnnnn :;Prwary I mtc mune ny cc�n t;ry ct,tnnl�yl;;tt•- nn ties n.n:
Under nonda taw,email addressess are publiC records.It you do not want your a-mad addrms released in response to a publit•records wiluest.do not:e:ntf cicctrvn.c
mall to this entity.Instead,Contact the orrice by phone or by traditional mail.If you live any questions,please contact o5o.dsi.1395-'Pursuant to Sett�an
455.27511),nonda Statutes,effective October 1,2012,licensees licensed under Chapter 45S,F.S.must provide the bepaitment witr an ernad address it they have
one.The email$provided may be used for official Communication with the licensee.However ernad addresses are public fccord.If you do not 1n,yh to supply a perIon4l
address,please provide the pepartment with an email address which can be made available to the public.To determine If you air a licensee under Chadfer 455,1.S.,
Please click r,nrn.
Product Approval Accepts:
Own® wki M
wruriitus nae
24
hops!/Oondabuilding.org/pr/pr_app_dti.aspx?flaram=wGEVXOwtDgiBNbEY5V%2boQT%2b6w7ahfZegiCOBucf26ixEAoiMeKNJKxtdlw°ia3d`3(I July i,2015
. .
EXTERIOR RESEARCH&DESIGN,LLC.
m*ificote of Avmorizaw^x9503
353CHRISTIAN STREET,UNIT xB
TRKN8~ Y ERD OXFORD,[T 06478
PHONE:(2O3)Z62'9%*5
FAX:(2V3)Z6]'92u3
EVALUATION REPORT
---'--Cor*|nm ------------------ �� Evaluation Report 037940'02'12'n6
One Owens Corning Parkway pL10674'wxn
Toledo,C*43a59 Date nfIssuance:na/$6/20z2
Revision 5: 04/22/201S
SCOPE:
This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The,clocumentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the S'h Edition(2014)Florida Building Code sections noted herein.
Dcscmpnow/ Owens Corning Asphalt Roof Shingles
Wcmms: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance nfthis
s,a|vation Report by the named client constitutes agreement*onotify Robert Nieminen,P.E.Kthe product changes urthe
referenced Quality Assurance documentation changes. Tdn|ty}ERD requires complete review of this Evaluation Report
relative toupdated Code requirements with each Code Cycle.
'
Auvsxr/Sawe^n/ The Evaluation Report number preceded by the words "Trnityl[KD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, acopy nfthis entire Evaluation Report shall heprovided tothe user bythe manufacturer orit%
distributors and shall beavailable for inspection mt the job site mtthe request nfthe Building Official.
This Evaluation Report consists ofpages Ithrough 6.
Prepared by:
Op
n."u�°�"*,"�^,.,,=.^°"^,,�","�~.~~..~..
M���mJ.on,N��m/men,P.E. .
Flotido xegii,,unvoNo.saunFmmmncnAxyz98m
CERTIFICATION orINDEPENDENCE:
I� 7hnxv|cxo does not have, nor does it intend to acquire or will it acquire, o financial interest in any company manufacturing o,
distributing products uevaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
s Robert micmin,n'p.a.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4n^»ertwicminwn P.E.does not have,nor will acquire,afioanWinterest in any other entity involved mthe approval process o/the
product.
5. This is building code*,a!vahn^. Neithr,T,in>ty|ERD nor Robert micminpn' rz.o,e, in any way, the uos`nne,of Record for :nv
project oowhich this Evaluation Report,or previous versions thereof,is/was used tor permitting or design guidance unless relamed
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance
with the following sections of the Florida Building Code and Florida Building Cade, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2A Physical Properties ASTM 03462 7009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM 03161 2009
1507.2,7.1.R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
LOWY ExRnlnatlon telgrence Date
Ut LLC(CER9626) Physicals&Wind Resistance Fite R2453,Vol.3 02/15/2007
UL LI.0(CER9626) Physicals&Wind Resistance 20120516-82453 05/16/2012
UL LLC(TS79628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance I ICA34308 02/18/2012
UL LLC(TS79628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
Miami-Dade(CER1592) FOC HVHZ Compliance Various NOAs Var rows
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp,08/20/2017
4, PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic'and Supreme are fiberglass reinforced,3-tab asphalt roof shingles,
4.1.2 Berkshire*are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"are fiberglass reinforced,S-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection,
TruDefinition Oakridge',Oakridge and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles.
4.2 Berkshire* Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles,
ProEdge Hip &Ridge Shingles and DuraRidge" Hip& Ridge Shingles are fiberglass reinforced,stip and ridge asphalt
roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles,
5. LimiTATiONS:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E, are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and 8905-2.6.1 to
ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to
V„a=150 mph(V,a,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
S.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FDC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to
V„n=150 mph(V,„=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R5
Certificate of AvthoHration 09503 FL10674-RlO
Revision 5:04/22/2015
Page 2 of 6
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20.3.
6.
INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
Berkshire*shingles require minimum five(5)nails per shingle.
WeatherGuard HP shingles require minimum six(6)nails per shingle.
;w Devonshire'"shingles require minimum six(6)nails per shingle.
Starter Strip Plus requires minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.S. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing--Classico&Supreme:
Norend Mansard or Area para Normal Mansard or Aro*para
Wind Arses High Wind deavanaa y Wind Areae High Wind daavenes y
Area pars vio»tos normal## Areas vionros foortrs Area parrs vionros normal** Areas vlontas fuorros
(o) st- ' �-tt► t {AI . L �• '' z' ?' a 1
6-Exposure8 818"Exposure
Exposial6n Fxposlel6a
6.2.6 Minimum Nailing–Berkshire®:
S"a4tq strip Spahn!tL�
it tot dr udNu U ttra rrs uI"t
— ------►o o----+e o.- -a.------+•
R h' A 1Y A rf A Vf 1 N�
r i_J
t
r..am mrm+++aa
Cpm odo whe dr A-16no
Euterior Research and Design,LLC. Evaluation Report 037940.02.12•R5
Cordlicate oJAuthurfrodon#9503 F110674-RSD
Revision 5:04/22/2015
Page 3 of 6
TRINITY ERD
6.2.7 Minimum Nailing–Devonshire`":
Nails
N41, Ten V Spots of Asohah Root Ctawki
6.2.8 Minimum Nailing–Duration*,TruDefinition'Duration,Duration'Premium Cool&TruDefinition Duration Designer
Color Collection;
4 Nad Pattern 6 Nei ......
6quonw do 4 cljvm Pmain
Ew#nt3 --
afft witith do 6 dovos
injev r, r
t -I*—
A
71,A
4f:E><powro Nails 6W Expostwo
Pi pu1q.di sxpotfrian cbvas 6UpuJq,d#oxpo%kJbn
N"O,
6.2.9 Minimum Nailing–TruDefinition*OakridgeO,CiakridgeO:
4 N411 Main 6 Nail PAWn
Esquoinj con d davo5 Fsquama C40 6 elavos
V
12-
711,
ss?w Exp&.uto fah 6 SIT Expa wo
t1jQ%
E%pa4dan d#6 Flepteg. clavof Gposicka do 6 G19p4dq G SIT Expowre cjjvos 5 Ue,krtx,�u
Ewpovvion do F 174piiq
6,2.10 Minimum Nailing–WeatherGuard*HP:
etc&Sub VL=
X
RMt2uarTb V.3%lit Low
e atdo
Exterior Research and Design,L.I.C. Evaluation Report 037940.02.12-RS
Cerfilkair of Authorization 8930.1 FL10674-RI0
Revision 5:04/22/2015
Page 4 of 6
TRINITY ERS
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire*Hip and Ridge Shingles,High Ridge, Hip& Ridge with Sealant,WeatherGuard HP Hip and
Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle, installation of UuraRidge"Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind
resistance and installation limitations,including the use of hand sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing–Berkshire'*Hip&Ridge and High Ridge:
i Fig.i _ _.Y.— j j Fig.2
'�\A -.VNtiii y
_....-^---r
,..:
42, 11
i
�C
i
6.3.4 Minimum Nailing–Hip&Ridge with Sealant:
imn Fig.2 o Nigh Wind Fastening Patwm
K Nails)
rine Shingle
nd Discard �., 2.r
Excess �rr ,lu
Sealant - i7_
Strip - 12"
'Fastening Vile i 5`r EXposun+e
Disdarnoe _I
92" —
6.3.5 Minimum Nailing–WeatherGuard•HP Hip and Ridge:
Fig.A
Fig.C Hip&Ridge Shingle Fastening
v v -
vrwv�opvrna .v'
1n`n, 4 i � •+• i 1
l _._......._�_..._ Exgfxuro 1
h
Ir
_ S
i
f
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Authorization 09503 FL10674-RIO
Revision S:04/22/2015
Page S of 6
TRINITY ERD
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Provailing Standard --ti'-- -
Wind Direction Sufxnt Strip pottering
ti'Exposure r,� �,' `.� �� r
• 12' __ �. tt_ Saotant
Fastan 71h' 7.!'. 6'Expsura
Cawr Exposed �, 1
Fasteners with
Roof CON M
6.3.7 Minimum Nailing-DuraRidge"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
PrositMVAWtl udon T.Pvw.+
Dw6dsmd7rnimm fb•cw VN•n p4n
Dinedan 4•t.iam yrfd—ifunta H#' Vue•fvptr«x !'��t
o"VMCwnf%j swdlar
C
V In$
�_. • . J t i i :g
NOVA
�
. .............. L
7. LABELING: i
7.3 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
S.O. QUALITY ASSURANCE ENTITY:
UL LLC-QUA9625;(414)248.6409;karen„.buchmann f ul.com
END OF EVALUATION REPORT-
Exterior Research and Design.U.C. Evaluation Report 037440.02.12-RS
Certificate of Authoritarian VM3 FL10674-R10
Revision 5:04/22/2015
Page 6 of 6
Florida Building Code Online
11 MIA
Zlv
3., 7 5-
ticis Home tog in uwr Reoktratton Not topics - submit surcharge scats tt t
Busines�t CA
Professional U51R Puubtilt Us".1 yat
®� yty'n..f,�ra=",y;.3.¢i.nrs%Frartr,,,rTgt tuph t�nR cr,.rn>rt.�oi,a,�4t3s�r%�PDiication DSK
Yz w afi fL 11 _ _. :1707.71-"ol'
" Application Type � Revision
Code Version / 2014
Application Status Approved
Comments
Archived 4
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorni6 com
Authorized Signature Greg Keeler
greg.keeler@owenscornirig.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emitil
Category Roofing r
Subcategory Underlay
glents"
Compliance Method Evaluation Report from a fiorida Registered Architect or a Licensed Honda
Professional Engineer
Evaluation Report-Hardcopy Received
i
Florida Engineer or Architect Name who developed the Zachary R.Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity
Quality Assurance Contract Expiration Date y 12/31/2020
Validated By `'----Lodke-Bowdein"
Validation Checklist-Hardcopy Received
4
Certificate of Independence FL9777 R4_CO� t O�„R1•i007�.( (} 2(71A Evalu t f?, > r 14 J js(
WeatherWrSk,ASIt
i
Referenced Standard and Year(of Standard) Mndard ! Vaar
ASTM D 1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
hilps:ilforidabLillding.org/pripr_app_dtl.aspx?param=wGEVXQwtDgtgkcMGblcW71°/a2fZr7gdugvKmDi6kDHtGtY%3d July t.2015
Florida Building Code Online Page 2 of 2
Product Approval Method Method I Option 0
Date Submitted 02123/2015
Date Validated 02/2412015
Date Pending FBC Approval 03101/2015
Date Approved 04/1512015 c
summary of piroducts
Fit.S Model,Number or Name Description
9777.1 Weatherlock G Weatherproofing Underlayment
Limits of Use installation instructions
Approved for use In HVHZ:No F1,9777� 4
Approved for use outside HVHZ.-Yes
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777
Created by Independent Third Party: Yes
9777.2 'Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
�1 Approved for use In HVHZ-.No FL9777 R4
II 0(:Tkl-j00,',1 F(jC 7()'41 F -j!V1jLjQfj ?i'jiip
s
Approved for use outside HVHZ-,Yes I FBC WCatjjetLork,Ddf
Impact Resistant:N/A I Verified By: Zachary R. Priest 74021
Design Pressure:N/A
Created by Independent Third Party:YeS
Other,See evaluation report for limits of use. I Evaluation Riports
2010 FMC Wcatherlock&SJ
Created by Independent Third Party:Yes
9777.3 WeatherLock Specialty Tile&Meta) Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ*No FL9,777 R4 ILO 4tu .I FIi�04
Approved for use outside HVHZ:Yes
Impact Resistant*N/A I Verified By:Zirchary R.Priest 74021
Design Pressure:N/A Created by Ind'ependent Third Party:Yes
Other:See evaluation report for limits of use, Evaluation Reports
R
2010 0 WcattjQrLjiA&jD0
Created by Independent Third Party;Yes
El
the State of Firioda is an NVECO employer.Cri-fight 2nr)7.7nl A-StAlm of nrinda.::
Under riptide law,einall addirmloM hit-Public records.11 You do not Want your e-mail moren released lrt,vipume to a Dubh(-recordsav riot sand tectrvilit
mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please t;Eifq.jsandto Section
.2 7',it 1),Florida Statutes,effective October 1.2012,ficerestift licensed under Cnapter 455,F.S.must provide the Department with all email jo,lr%s 11 tia:r
one,The errviift provided may ho used ror official communication with the licensee.However email addresses Are public wco,d,It j,nj� 1,,
address,please provide the Department with an email address which can be made available to the Public.Tv determine if you are a hcenst:c under
(nAlite,455.
vita"click ht=.
Product Approval Accepts;
,Cl.aril N i i,i,
https:,,Iflortdabuilding.orgiprlpr_app_dti.aspx?pararii=wGEVXQwtDqtgkcMGbicW71%2(Zr7gduqvKtnDj6kDH,16tY%3d July 1.2015
Certificate of Authorization iDn bur h 9824
rCREEK
17520 Edinburgh Drive
r., Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23. 2015
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
�vtivw__owen�cc�rning.com
Manufacturing Location: Brentwood,NH
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507,2.4, 1507.2.13, 1507.2,9.2, 1507,3.3, 1507.4.5, 1507.4.5.2, 1507.5.3,1507.5.3.2,
1507.7.3, 1507.7,3.2,
Properties: Physical properties
REFERENCES
EntityReport No. $ n ar Year
PRI Construction Materials Technologies(TST6049) NEI-039.02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-042-02-Ot REV2 ASTM D 1970 2009
PRi Construction Materials Technologies(TST6049) NEi-045.02.01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI.045.02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995
PRi Construction Materials Technologies(TST6049) NEI-053.02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock}G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt. a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLockO G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles,and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock®Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. roils with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock(b Mat is permitted to be used with mechanically fastened asphalt shingles.
wood shakes or shingles. and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® WeatherLock(D Specialty is an ASTM D 1970 self-adhesive underlayment constructed
Specialty Tile&Metal from SBS modified asphalt and surfaced with a non-woven polyester fabric. The product
is supplied in 2 sq. roils with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. rolls with
OCR14002.1 FL9777-R4 Page I Uf 3
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
I echnical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid,
I his evaluation.report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock@ Self-Seating Ice&Water Barriers
TECHNICAL SERVICES, LLC
nominal dimensions of 3-ft x 71.3-ft.
WeatherLock® Weathert-ockO Specialty Tile&Metal is permitted to be used with mechanically fastened
Specialty Tile&Metal asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or
(continued) shingles, and slate roofing as prescribed in the FBC. Weathert-ocke Specialty Tile &
Metal is permitted to be used with adhered clay or concrete the rooting using either 3M T%1
2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BOND TM Roof
Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of -45
psf and in accordance with the system approval. Exposure on the roof deck shall be
limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
PRODUCT APPLICATION
Min.Roof Slope: 2:12 or in accordance in with FBC
Application: Deck substrates shalt be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be chocked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the undorlaymont shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed direct-to-plywood decking with the release backer
removed and pressed firmly into place to ensure complete contact with the deck. The
underlayment shall be installed with the roll length parallel to the eave, starting at the
save, and with minimum 3"side laps and minimum 6"staggered end laps. End laps for
WeatherLockO Specialty Tile&Metal shall be primed with ASTM D 41 primer or sealed
with asphalt roof cement a minimum of 3-4 inches across the width of the lap.
It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be
installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). WeatherLock@ Specialty Tile & Metal shall be back nailed when
installed on roof slopes greater than 3:12.
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection, the underlayment should
extend to a point 24-inches inside the exterior wall.
The underiayment shall be installed over metal drip edge at the eave,and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min.Application 404F;Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shalt comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for now or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) All products listed in this reporl shall be manufactured under a quality assurance program in compliance with
Rule 611320-3.
OCR14002.1 FL9777-R4 [",age 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
CREEK WeatherLock@ Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
#,f,........ 2015.02.2
%
GENj
No 740213 14:45:39
-05,00,
STATE OF
A%
4 0 S 11 10" N Zachary R.Priest,P.E.
- 0 Florida Registration No, 74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest In any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P,E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of Ihe
product.
END OF REPORT
OCR14002,1 FI-9777-R4 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturor shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,Installation, recommended use,or other product attributes that are not
specifically addressed herein.