HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772) 460-4244
EMAIL cookmenard@yahoo.com
September 1, 2015
Saint Lucie County Building Department
Attn: Roof Permit Plan Review p
0
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at::- .
330 N. Brocksmith Rd.,Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply& Manufacturing
Profiles: 26 GA 5v Crimp Roof Panel FL.#11651.12
Code: FBC 2014;Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: C
Mean Roof Height: 30' Maximum
Pitch: 5/12
Required Design Pressure: Zone1:-46.2 Zone 2: -65.2 Zone3: -122.6
Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12" o.c., &-156.5 @ 6" O.C.
Fasteners: #9-15 x 1-%" HWH w/Sealing Washer with'/" minimum penetration spaced @
12"o.c. zone 1 & 2, & 6" o.c. zone 3
Underlayment: Soprema, Inc. FL#2569.1 Lastobond Smooth Seal HT is a self-adhering, glass-mat
reinforced,film-surfaced, sbs modified bitumen
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru
,out Zone 1,4" o.c. perimeter& 6" o.c. field Zone 2, and 4" o.c.thru out Zone3
The above approved, as per Florida,Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
Respectfully Submitted,
:J
Peter B. Cook
Cook&;Menard Architecture, Inc.