HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772) 460-4244 EMAIL cookmenard@yahoo.com September 1, 2015 Saint Lucie County Building Department Attn: Roof Permit Plan Review p 0 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at::- . 330 N. Brocksmith Rd.,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply& Manufacturing Profiles: 26 GA 5v Crimp Roof Panel FL.#11651.12 Code: FBC 2014;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 5/12 Required Design Pressure: Zone1:-46.2 Zone 2: -65.2 Zone3: -122.6 Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12" o.c., &-156.5 @ 6" O.C. Fasteners: #9-15 x 1-%" HWH w/Sealing Washer with'/" minimum penetration spaced @ 12"o.c. zone 1 & 2, & 6" o.c. zone 3 Underlayment: Soprema, Inc. FL#2569.1 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced,film-surfaced, sbs modified bitumen Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru ,out Zone 1,4" o.c. perimeter& 6" o.c. field Zone 2, and 4" o.c.thru out Zone3 The above approved, as per Florida,Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, :J Peter B. Cook Cook&;Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789