HomeMy WebLinkAboutEngineering SEP 0 81.015 INC. RECEI .D PAUL WELCH Mechanical *Electrical * Civil ngineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -988 Email pwelchinc@aol.c m SEPTEMBER 3,2015 RE: FERNANDEZ DO R INSTALL 387 MIDWAY RD. FORT PIERCE,FII SCOPE OF WORK o REMOVE EXISTING WINDOW AT REAR O EXISTING RESIDENCE, CUT NEW OP FORNEW DOOR ■ INSTALL NEW DOOR IN ACCORDANCE WITH PRODUCT APPROVAL AND MANUFACTURER'S INSTALLATION D STRUCTIONS. ■ INSTALL EXTERIOR LIGHT AND SWIT H ON INTERIOR_ NOTES: 1) THE CONTRACT R,SUBCONTRACTOR,SUPPLIER,ECT SHALL VERIFY ALL DIMENSIONS, CONDITIONS A JOB SITE,PLANS,SPECIFICATIONS,E T. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CbNSTRUCTION PROGRESSES. 3) ALL WRITTEN D�ENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCGTION MUST COMPLY WITH THE FLO A BUILDING CODE(FBC)2014,FBC 2014 RESIDENT FBC 2014 PLUMBING CODE,FBC 2014 MECHANICAL CODE,FBC 2014 ENERGY CONSEttVATION,AND THE NEC(NEPA 70)20H.EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERINGAZEA,AND IN VERY HEAVY TERMITE INFESTATION A1tEA PER FISC 301. 6) ALL ADDITIONS REPAIRS,AND ALTERATIONS MUST OMPLY WITH THE F.B.0 2014 FOR EXISTING BUILDINGS. 7) THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2014 FOR EXISTING BUILDINGS CHAPTER 7 AND 8. OONCEALEO FASTENERS OR ATTACHMENTS STRUCTURAL NOTES ARE THE RESPONSIBILITY OR THE 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. A�� �Q� � ATED. 2) ALL LUMBER INCONTACT WITH CONCRETE OR MASO 5 RE 3) SPLTTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 4) UNLESS OTHERWISE NOTED,THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO TETE MANUFACTURES INSTRUCTIONS STANDARD PRACTICIES. ST. LU IE COUNTY BUILDI JG DIVISION FOR O �';D Fri' E LL� � " u !.C, °„° REVIEWED B` •,4�,>; X4,' `'o. DATE T / •� - P1�4�lS fAIDLS? IT PAUL WELCH-INC-t.:�� MUST BE KEPT ON JOB OR 7 j' NO INSPECTl01N WILL BE PAADE Paul Welch,P.E. Reg.No 29945 September 3,2015 FILOL” O _._ 1 of 5 RERNANDEZ DOOR INSTALL 387 MIDWAY RD. FORT PIERCE,FL 20 19 USAF AREA OF ENLARGED FLOOR PLAN A 10 A;: CLPA '80) 4990) GAA 26 BAS 26 23 15 t 18 P,€�S NORTH ---� .AREA OF WORK-PLAN nts. NEW DOOR 3068 S.C.DOOR -- 4. APPLIED DP:+27:5 I-29.8 PSF EXISTING COV.PORCH AND.LA ING NEW LIGHT WINDOW REMOVED NEW DOOR INSTALLED _ _.... f NEW SWITCH _ _ MEMO -Ram - ,�" z 1 'EXISTING CLST l EX6STINGIDENC - ENLARGEDFLO PLAN= fA 7 '7, 4 ` x3 py PAUL WELCH INC_F r Paul Welch,P.E Reg.No 29445 2 of 5 FEWANDEZ DOOR l C f 1f U- 389 MIDWAY RD. FORT PIERCE,FL EXISTING ROOF TRUSSES EXISTING CONC.BEAM — —._--_ _-- EXISTING CMU WALL IX OR 2X P.T.BUCK{TO COVER ` } ENTIRE WIDTH OF JAMB) PROVIDE 11/2"CASEHARD NAILS @ 4"FROM ENDS AND 8" O.C. ._x EXISTING VERT REBAR AND .9 FILLED CELL EACH SIDE EgST I G WINDOW REMOVED/ NEWDOOR INSTALLED EXISTING CMU AND SILL REMOVED BELOW WINDOW ti OPENING _ 1 CONCRETE FND NOTCHED AS NEEDED+/-1"FOR DOOR � . INSTALL EXISTING FOUNDATION DOOR OPENING IN EXISTRiG WALL D►L+TAILnts... ILE CO' Y PAUL WELCH INC-. f m ; Paul Welch,P.E. Reg.No 29945 September 3,2015 __.------.__-. 3of5 Planning & Development Services Department Building & Regulations Division Product Review Affidavit FERNANDEZ DOOR INSTALL I Building Permit# Owners Name 387 MIDWAY RD. Applicant: — FORT PIERCE,FL I--- Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Desl n Pressure Number Type .Windows---..._.......__......----------- -�...__. -...... ... .. _............. _-1........._. . _ . . ..._.. .. ...._._._.._....._... . .. .. ..... ---.. :.... .._... .._.. .._ Mullions Fixed Glass Block Glass Skyllghts Sliding Glass Doors Swing Type Doors t2�L,5 •29,x' +/- SS JFI.p-weN ColiTok)'>zS FLoi !35¢0, tj1a 3/���,c I /q"` LAW tMgep TAPcaNS French Doors frS F ?5F Garage Doors N A Hurricane Protection Roof Ventllaflo Roofing Ma I have r d the above components or cladding and I have approved their use in this structure. 'These products provide adequate resistance to the W! to forces specified by current code provisions. UL WELCH P.E. Name: Signature: Design Prof: . PAUL WELCH P.E. Cert.No. 29945 Date: 9'1320/S� o - �n ; cn i t d Planning&Development Services Department 5-M - COUNTY _ .I Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: FERNANDEZ DOOR INSTALL Project Address: 387 MIDWAY RD. Permit#: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: I •This cerlhliiwtion must be completed,signed,and sealed by the design professional of record. •Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. *Note:Foran not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. I DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) 1.DESIGN CODE:Florida Building Code 2014 Edition with 20 Supplements using ASCE 7-10 2.Structure Designed as(check one): X Enclosed _Partially Enclosed Open 3.Risk Category:_1 X II 111 IV Exposure Category: X B C'. D 4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width:; 5 ft S.Mean Roof Height: 30 ft Roof Pitch: N/A :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openin .): 16.0 16.0 16.0 27.6 27.6 N/A Zone 1: _25.3 Zone 2: -44.0 Zone 3: _65.1 Zone 4: _30.0 Zone 5: _37.0 Garage: N/A 7.Design Loads:Floor: 40 PSF Roof/Dead: N/A PSF Roof/Live: N/A I'Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENT TED 8.Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: i 9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: I 10.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: 1 certify that,to the best of my knowledge and belief,the attached plans&specifcations have b e o C()PY comply wlth;the applicable-structural portions of the building codes currently addpted and enforced 4by 3't�uc�e 4, , County.I also certify�thatstructurZ.al elements depicted on these plans provide adequate resistance to the design forces specified:-.',,-,-- Paul Welch PIE. 299415 / 5115 Print Name Cert#&Co. ert Auth. Paul Welch Inc. Signature;Date,and Seal 1984 S.W. Bil�tmore St.Suite#114 Port St.Lucie,FL Company Name&Address SLL66V Norm#UL(1 11 Kewsetl 3/T5%11:j75) -; 5 of 5