Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 {moi x S Fle-fida Npirtiner it! Bcts Home Log In user Registration Hot Topics Submit Surcharge Stats&Facts `s Publications FBC Staff i BCIS Site Map Links Search Busines � eS��t��a� USER:Public U erOVa� P rof Product Regulation Product Approval Menu>Product or Aoolication Search>Application Liss>Application Detail 6, FL# FL10450-R6 Application Type Revision Code Version 2014 Application Status Approved Comments Archived 1.. Product Manufacturer Tarco Roofing Address/Phone/Email One Information Way Suite 225 Little Rock,AR 72202 (254)913-7750 smohseen@tarcoroofing.com Authorized Signature Shaik Mohseen smohseen@tarcoroofing.com Technical Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 76513 (254) 913-7750 smohseen@tarcoroofing.com Quality Assurance Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 78717 (254) 939-3775 Ext 210 smohseen@tarcoroofing.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Roll Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/13/2017 Validated By John W. Knezevich,PE W( Validation Checklist-Hardcopy Received Certificate of Independence FL10450 R6 COI 2015 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D3909 1997 ASTM D4869 2005 ASTM D6164 2005 ASTM D6380 2003 FM 4474 2004 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDqudsDrIH6I4890... 9/8/2015 Florida Building Code Online Page 2 of 2 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/02/2015 Date Validated 07/02/2015 Date Pending FBC Approval 07/10/2015 Date Approved 08/18/2015 Summary of Products FL# Model, Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FI 10450 R6 II 7.015 07 FINAL- ER TARCO UNDERLAYMENTS FL10450- Approved for use outside HVHZ: Yes R6,Qdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party:Yes Other: 1.)The design pressure herein Evaluation Reports pertains to one particular bonded FL10450 R6 AE 2015 07 FINAL ER TARCO UNDERLAYMENTS FL10450- underlayment application for use beneath R6.Ddf adhesive-set tile systems.Refer to ER Section Created by Independent Third Party:Yes 5.6.2 for details,and other bonded underlayment systems.2.)Refer to ER Section 5 for Limits of Use. Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.:;Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: am W-N 99 sceuritvm rrik ws� https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I4890... 9/8/2015 JTRINJTY ERD Certificate of Authorization #9503 January 1, 2015 RE: Certification of Independence, Florida F.A.C. Rule 61 G20-3 To Whom It May Concern: This letter serves to document the following in accordance with Florida F.A.C. Rule 61 G20-3: I. Exterior Research &Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any u, company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Please contact our office with any questions. Sincerely, Robert Nieminen, P.E. Florida Reg. No.59166 �! Vice President Email:robertnieminen@trinityerd.com j !' { EXTERIOR RESEARCH & DESIGN, LLC. d/b/a Trinity]ERD — Certificate of Authorization #9503 MAIN:80 Yesler Way . Suite 200 . Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840 EAST: 353 Christian Street Unit 13 . Oxford, CT 06478 . P: (203) 262-9245 . F: (203) 262-9243 it „r EXTERIOR RESEARCH&DESIGN,LLC. ss. Certificate of Authorization 119503 353 CHRISTIAN STREET, UNIT#13 \,,, ry EL OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Tarco Roofing Evaluation Report 10880.07.08-116 J,IrIT", One Information Way,Suite 225 FL10450-R6 Little Rock,AR 72202 Date of Issuance:.07/11/2008 Revision 6:07/02/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described I herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. !t' cl This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen, z F` •'-C•?ti`•*�`,• P.E.on 07/02/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 ''z,`S�r^��L%;.`� document.Signed,sealed hardcopies have been transmitted to tl,e Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. .. ii ,r rf I = ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Tarco, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.3,1507.2.8,1507.4.5.1, Physical Properties ASTM D4869 2005 1507.4.5.2,1507.5.3,1507.5.3.2, 1507.7.3,1507.7.3.2,1507.8.3, i 1507.8.3.2,1507.9.3,1507.9.3.2 1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009, 1507.2.9.2 Physical Properties ASTM D3909 1997 1507.2.9.2,1507.3.3 Physical Properties ASTM D6380 2003 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 . a 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007 ERD(TST6049) FM 4474 T6460.06.07-R1 10/09/2007 ERD(TST6049) ASTM D1970 T30160.08.09 08/14/2009 ERD(TST6049) TAS 103 T33190.08.10 08/06/2010 ERD(TST6049) ASTM D1970 T32530.08.10 08/17/2010 ERD(TST6049) FM 4474 T37610.07.11 06/29/2011 ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012 ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012 ERD(TST6049) TAS 103 T35410.04.12 04/18/2012 ERD(TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 ERD(TST6049) Physical Properties T43930.09.13-R2 09/11/2013 ERD(TST6049) Physical Properties TAR-SC9480.15 07/02/2015 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004 PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005 PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 PRI(TST5878). ASTM D4869 TOT-009-02-02 09/14/2004 PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006 J Miami-Dade(CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013 UL,LLC.(QUA9625) Quality Assurance Service Confirmation Exp.10/13/2017 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: i 4.1.1 LeakBarrier Fast90 Self-adhering Tile Underlayment is an asphalt-saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self-adhering compound and I release film. 4.1.2 LeakBarrier MS300 Ice and Water Armor is a self-adhering,glass mat reinforced, mineral surfaced,SBS modified roof underlayment. 4.1.3 LeakBarrier PS200HT Ice and Water Armor is a self-adhering, glass mat reinforced,fabric surfaced, SBS modified roof underlayment. Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-116 Certificate of Authorization#9503 FL10450-R6 Revision 6:07/02/2015 Page 2 of 8 4 I I `ERD 4.1.4 LeakBarrier PS200Mu Ice and Water Armor is a self-adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment. i ' 4.1.5 LeakBarrier-NR500HT is a self-adhering,plastic film surfaced,modified underlayment. k lig 4.1.6 LeakBarrier SS400 Ice and Water Armor is a self-adhering, fiberglass reinforced, smooth surfaced modified i underlayment. 4.2 Mechanically Fastened Underlayments: 4.2.1 Tarco 15 is an ASTM D226 Type I, 15 Ib asphalt-saturated organic felt 4.2.2 Tarco 30 is an ASTM D226 Type II,30 Ib asphalt-saturated organic felt 4.2.3 Tarco NO 30 is an ASTM D4869 Type II asphalt-saturated organic felt 4.2.4 LeakBarrier EasyLay is an asphalt-coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass-fiber-reinforced, asphalt-coated, granule surfaced underlayment used as a valley liner. 4.3.2 ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt-saturated organic roll roofing sheet. 4.3.3 LeakBarrier EasyMop—SBS is a polyester reinforced,SBS modified bitumen roofing underlayment. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. pF r� 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop Tarco underlayments are follows: TABLE 1: ROOF COVER OPTIONS i Wood Shakes& Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Slate Shingles L LeakBarrier Fast9Q Yes Yes Yes No Yes Yes 6 See 5.5.2 LeakBarrier MS300 Yes No No No Yes Yes LeakBarrier PS200 HIT Yes Yes Yes Yes Yes Yes See 5.5.2 LeakBarrier PS200 VU Yes No No Yes Yes Yes LeakBarrier NR500RT Yes No No Yes Yes Yes (No copper or zinc) LeakBarrierSS400 Yes No No No Yes Yes Yes Yes LeakBarrier EasyLay Yes (as base layer in 2- (as base layer in 2- Yes Yes Yes ply system) ply system) Tarco 15 yes No No Yes Yes No Yes Yes Tarco 30 Yes (as base layer in 2- (as base layer in 2- Yes Yes Yes ply system) ply system) Tarco NO 30 Yes No No Yes Yes Yes (double layer) (double layer) (double layer)y ) (double layer) Fiberglass Mineral Surfaced Yes Valley Liner per No No No No No Roll Roofing 1507.2.9.2(2) r: I ASTM Organic Mineral Yes Yes Yes No Yes Yes Surface Tile Underlayment See 5.5.2 i Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-16 Certificate of Authorization#9503 FL10450-R6 ; i. Revision 6:07/02/2015 Page 3 of 8 �jl�,l,� TRINITY !i ERD TABLE 1: ROOF COVER OPTIONS,. Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes& Slate Shingles LeakBarrier EasyMop SBS Yes Yes See 555.2 YeNo Yes Yes 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrier self-adhering top layer or asphalt-applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam-On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332) applications unless tensile adhesion/long term aging data from an accredited testing laboratory is provided. 5.6 Allowable Substrates: 5.6.1 LeakBarrier self-adhering direct-bond to deck: ➢ New untreated plywood(unprimed or primed with ASTM D41 primer); ➢ Existing plywood(unprimed or primed with ASTM D41 primer); ➢ Structural concrete(unprimed or primed with ASTM D41 primer). LeakBarrier PS200HT self-adhering direct-bond to deck: ➢ New untreated plywood(unprimed or primed with ASTM D41 primer); ➢ Existing plywood(unprimed or primed with ASTM D41 primer); ➢ New or existing OSB(unprimed or primed with ASTM D41 primer); J' ➢ Structural concrete(unprimed or primed with ASTM D41 primer). Note: Tarco does not require priming o new or existing plywood or OSB sheathing. New or existing plywood or OSB 9 P 9 f 9PY 9• 9PY sheathing should be Cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Direct-Bond to Deck: ➢ ASTM D41 primed structural concrete. 5.6.2 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FBC 1609 for determination of design wind loads. 5.6.2.1 Maximum Design Pressure=-217.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: LeakBarrier P5200 HT,self-adhered. 5.6.2.2 Maximum Design Pressure=-75.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional)ASTM D41 ^'• Underlayment: LeakBarrier PS200HT,self-adhered. 5.6.2.3 All other direct-deck, adhered Tarco underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. 5.6.3 Bond to Mechanically Attached Base Sheet: LeakBarrier self-adhered to: ( E I ➢ ASTM D226,Type I or II felt; i ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D226,Type I or II felt; ➢ ASTM D4601,Type II base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12). Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R6 Certificate of Authorization#9503 FL10450-R6 Revision 6:07/02/2015 Page 4 of 8 41TRINITY ERCP i 5.6.4 LeakBarrier Self-Adhering Bond to Other Substrate Types: i Jilll ➢ ASTM D41 primed metal(flashing metal,valley metal,etc.) 5.7 Exposure Limitations: 5.7.1 LeakBarrier EasyLay, FAST 90,ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS shall not be left exposed for longer than 180-days after installation. 5.7.2 LeakBarrier PS200"T shall not be left exposed for longer than 120-days after installation. 5.7.3 LeakBarrier MS300,NR500"T,PS200Mu or SS400 shall not be left exposed for longer than 30-days after installation. 5.7.4 Tarco 15,Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after installation could adversely affect performance. 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and primed the substrate(if applicable). 6_3 LeakBarrier°Fast900 Self-Adhering Tile Underlayment: 6.3.1 EasyLay shall be installed in compliance with the requirements for 90#felt underlayment(except the product is self- adhered)in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: Cut the Fast90 roll into 12'to 16'sections for workability and allow to relax prior to application. Chalk a plumb line 36"from all outside perimeters;then chalk plumb lines 32"apart,upslope to the ridge line. a Membrane Application: ➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with the selvedge edge positioned upslope and in-line with the 15`chalk line. ➢ Fold back half the sheet and remove the exposed release film,taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges, and repeat for the other half of the sheet. ➢ Remove selvage release film, if present,and install capped or tin tagged nails 6" o.c. in the center of the selvedge edge. ➢ Install the subsequent sheets in the same manner,with upslope selvedge edges in-line with chalk lines,with 4"side ! I' laps and 8"end laps. ➢ Seal all 8"end laps 1/16"thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.3.4 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. All tiles shall be staged four tiles perpendicular to slope,six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above,the tiles shall be staged behind a nominal 1 x 2 horizontal batten. w ,i l a ' Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-R6 certificate of Authorization 119503 FL10450-116 Revision 6:07/02/2015 Page 5 of 8 -rY j ITRINI ERD 6.4 LeakBarrier°MS300,PS200"T,PS200Mu,NR500"T or SS400 Ice and Water Armor: 6.4.1 MS 300, PS200"T, PS200MU, NR500"T or SS400 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Non-Tile Applications: Cut MS 300,PS200"T,PS200m',NR500"'or SS400 to manageable sections and allow to relax prior to application. Membrane Application: ➢ Place a full width piece on the prepared substrate,aligned parallel to the eave edge and extend approximately 3/8" I„ over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate,taking care to avoid wrinkles and ridges ➢ Apply a 1/16"thick layer of asphalt plastic cement over the eave and rake metal,extending 2"to 3"onto the deck surface. ➢ Fold back the downslope half of the sheet,remove the release film and roll the membrane onto the substrate from I�h the centerline out. ➢ Seal all 6"end laps with a 1/16"thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film,if present,and install second and subsequent courses in a similar manner. ➢ Install capped or tin-tagged nails 6"o.c.along the centerline of the laps. ➢ At all T-joints, where an end-lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.4.3 Tile Applications(PS200"T only): Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. All tiles shall be staged four tiles perpendicular to slope,six tiles on top,parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. a) At roof pitch in excess of those noted above,the tiles shall be staged behind a nominal 1 x 2 horizontal batten. , 6.4.4 Two(2)Ply Underlayment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct-to-deck per 5.6.1 or over mechanically attached base sheet per 5.6.3) is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement, but isI allowable if a 2-ply underlayment system is desired. I' 6_5 Tarco 15 and 30: 6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226,Type I and II underlayments, respectively,in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.5.2 Non-Tile Applications: Reference is made to the current edition of the NRCA Steep-slope Roofing Manual. 6.5.3 Tile Applications,base laver in 2-ply system(Tarco 30 only): Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein. 6.6 Tarco NO 30: 6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1), 1507.7.3.2 (1), 1507.8.3.2(1)or 1507.9.3.2(1). Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R6l Certificate of Authorization#9503 FL10450-116 Revision 6:07/02/2015 Page 6 of 8 :, I. l J ` �°,,H ER 6.7 LeakBarrier EasyLay: �trr 6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC 7 Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove ;a any dust and debris prior to application. ' .t 6.7.3 Non-Tile Applications: Place a full width section of EasyLay,parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull,straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8"headed roofing nails or 1"capped(plastic or metal)nails,driven by hand or pneumatically,spaced 6"o.c.at all laps in the center of the seam area,and two staggered rows fastened 12"o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.Align the next roll over the preceding sheet so as to form a minimum 4", water-shedding lap, and install per instructions above. Apply subsequent sheets in the same manner,with minimum 4" water-shedding laps and minimum 8"end-laps,which are staggered minimum 36"fro the preceding course. For double layer applications,follow the instructions noted above,but using a minimum 19",water-shedding side lap. Allow for minimum 6"up the vertical transitions and minimum 6"over hips and ridges. At valleys,first install a vertical length of EasyLay down the center of the valley,then start at the low point and work to ;. the high point, rolling the membrane from the center outward in each direction, ensuring no wrinkles or tears. h Covered with valley-metal or other valley lining material in accordance with NRCA recommendations. Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require adhesive or sealant can be treated with high quality plastic cement(asbestos free). 6.7.4 Tile Applications,base layer in 2-ply system: g' -Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein. &&. 6_8 ASTM Organic Mineral Surface Tile Underlavment: 6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 Non-Tile Applications: Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings. 6.8.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6_9 LeakBarrier)EasyMop SBS: 6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the limitations herein. 6.9.2 Non-Tile Applications: For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing nails or 1-inch diameter cap-nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two (2) equally spaced, �d staggered center rows in the center of the sheet. End-laps shall be minimum 6-inch wide, and offset end-laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco requirements. For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-inch and end-laps minimum 6-inch wide, and offset end-laps minimum 3-feet from course to course. Side and end-laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco instructions regarding back-nailing requirements. , Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R6 Certificate of Authorization#9503 FL30450-116 Revision 6:07/02/2015 Page 7 of 8 (JTRINI-rYIERD 6.9.3 Tile Applications: Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C.Rule 61G20-3 CIA requirements �• s 9. QUALITY ASSURANCE ENTITY: UL,LLC.—QUA9625;(847)664-3281 -END OF EVALUATION REPORT- ;o p i Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-R6 Certificate of Authorization#9503 FL10450-116 J Revision 6:07/02/2015 Page 8 of 8 Florida Building Code Online Page 1 of 2 hlcn �[k(Jtm°�t BCIS Home Log In ! User Registration ; Hot Topics : Submit Surcharge i Stats&Facts Publications FBC Staff ; BCIS Site Map Links ; Search B u s i n e s Professi al , °d"°t Appr°"a' USER:Public User Regulation Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL10124-1115 Application Type Revision Code Version 2014 Application Status Approved Comments Archived I Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (973) 872-4421 Iindareith@trinityerd.com Authorized Signature Beth McSorley Iindareith@trinityerd.com Technical Representative Beth McSorley(current) Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (973)872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Ji Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/21/2016 Validated By John W. Knezevich,PE Validation Checklist- Hardcopy Received Certificate of Independence FL10124 R15 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 TAS 107 1995 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeV CbdM... 9/8/2015 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 03/31/2015 Date Validated 04/08/2015 Date Pending FBC Approval 04/12/2015 Date Approved 06/23/2015 Date Revised 08/25/2015 SummarV of Products FL# Model, Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R15 II 2015 Q3 FINAL ER G6E_AspftaJl Approved for use outside HVHZ: Yes Shingles FL10124-R15.Ddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER, Section S. Evaluation Reports FL10124 R15 AE 2015 03 FINAL ER GAF Asphalt Shingles F1-10124-R15.pdf Created by Independent Third Party: Yes Dock Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: I- fCAeck SpCltYltV\43iT1i1CS` https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeV CbdM... 9/8/2015 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code I" Product Approval Method Method 1 Option D Date Submitted 03/31/2015 Date Validated 04/08/2015 Date Pending FBC Approval 04/12/2015 Date Approved 06/23/2015 Date Revised 08/25/2015 Summary of Products 1 Ills FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R15 II 2015 03 FINAL ER GAF Asphalt Approved for use outside HVHZ:Yes Shingles FL10124-R15_ydf Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER,Section 5. Evaluation Reports FL10124 R15 AE 2015 03 FINAL ER GAF Asphalt Shingles FI-101.24-RI5.pdf Created by Independent Third Party: Yes tiactt........-... l_ _ 4, Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 { The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. *Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department I with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public dj ) record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. y j To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts:OEM I• SCCUrit\'jt 2i'Ctt t4:ti' I'" 1 l l l https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbd... 8/27/2015 i,. i;�a• EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT 413 a4,_ ERCP OXFORD,CT 06478 PHONE:(203)262-9-L l FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1117 1 Campus Drive FL10124-R15 • �1,. Parsippany, NJ 07054 Date of Issuance:01/03/2008 �;; Revision 17:03/31/2015 r SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. A, ,a CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced g' Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of i this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising Literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: )JIMMY", Robert J.M. Nieminen P.E. °i�So ��"� The facsimile seal appearing was authorized by Robert Nieminen, z ,. �r7;�L�t,` P.E.on 03/31/2015.This does not serve as an electronically signed ned -.✓Jlf111Nr H Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. :'i' 2. Trinity[ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any a; project on which this Evaluation Report, or previous versions thereof, is/.was used for permitting or design guidance unless retained specifically for that purpose. l 'E Y TR I ITT I ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. a 2. STANDARDS: hl, Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 ! 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 ! PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK05632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CAS367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 ]]; UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 >3 ` UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/20071' I UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 lOtA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 IkA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1117 Certificate of Authorization#9503 FL10124-1115 .rd Revision 17:03/31/2015 Page 2 of 5 k ., ..$f TRINITY ERD 11 Entity Examination Reference Date UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 i UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 l l� UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/20111;•I UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 11/21/2014 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/06/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 02/20/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 02/19/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shaffer,CA 01/05/2015 UL,LLC:(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 02/23/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/16/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 02/10/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 02/11/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 03/05/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/25/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 03/07/2015 i UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/02/2015 4. PRODUCT DESCRIPTION: C 4.1 Asphalt Shingles: 4.1.1 Marquis®WeatherMax°,Royal Sovereign'and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles. I 4.1.2 Camelot®, Camelot° II, Country Mansion® II, Grand Canyon®, Grand Sequoia°, Grand Sequoia® IR, Monaco', Sienna', ` ,Timberline American Harvest®, Timberline° ArmorShield"" II, Timberline®, Natural Shadow°, Timberline HD°, Timberline® Cool Series, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline°is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 .Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles;Seal-A-Ridge° IR Impact-Resistant Ridge Cap Shingles and Timbertex° Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strips: 4.3.1 P'ro-Start° Starter Strip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or .design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. [[ 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„!t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 1 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for us in all wind zones up to Va,d= 150 mph (V„!t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1137 Certificate of Authorization#9503 FL10124-1115 Revision 17:03/31/2015 Page 3 of 5 �­JTRINrry I ERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: II 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Starter Shingles: 6.2.1 Installation of Pro-Start Starter Strip Shingles and WeatherBlocker Premium Eave/Rake Starter Strip shall comply with the manufacturer's current published instructions. !{; 6.3 Asphalt Shingles: i1 ` I! I 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL 530 Roof&Flashing Sealant". 11.5" Sealant 1^ (292 mm) 1^ (25 nun) (25 mm) Sellante Enduit d'etancheile _ 12„ s (305 1 mm.) �r Nail N{ Clavo 6 5/8"-7 5/8" Clouer (168-194 mmj 1 12' (305 mm) Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R37 ; Certificate of Authorization#9503 FL10124-R15 ki Revision 17:03/31/2015 r Page 4 of 5 i I�'iP i TR -ff IN ED 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current 4published ' instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn I Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. it's, 8e�tatst F; t ( rritrif t, f twirl) (2S rrint t�nduidui td t d htsncJ*tli rrct r (305 rrn) ly (22:0 mc(rl, t"�5 rtti;r�l ' 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: e 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(847)664-3281 END OF EVALUATION REPORT- 7 Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1117 Certificate of Authorization#9503 FL10124-R15 Revision 17:03/31/2015 Page 5 of 5 MIAMI-DADE COUNTY MIAMI.DADE�� REMPRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.mian�id<�de_g��vtec+2nost�t GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: '' This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). j I' This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Royal Sovereign Shingle i LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. , TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 12-1127.03 and consists of pages 1 through 4. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 14-1022.16 MIAMI•DADE COUNTY Expiration Date: 04/22/18 11 Approval Date: 02/05/15 ,i'•`! Page 1 of 4 t r ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials 3-Tab Deck Type: Wood SCOPE This approves GAF Royal Sovereign Shingle as manufactured by GAF as described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Royal Sovereign Shingle 12"x 36" TAS 110 Fiberglas reinforced heavy weight asphalt roof shingle,with a 3-Tab profile MANUFACTURING LOCATIONS 1. Savannah, GA. 2. Tuscaloosa,AL. 3. Tampa,FL. 4. Mt.Vernon,IN. 5. Mobile,AL. 6. Dallas, TX. 7. Myerstown,PA. 8. Fontana, CA. i 9. Minneapolis,MN. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering TAS 100 02/23/94 ASTM D3462 257966 03/21/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-105-02-01 11/14/05 TAS 100 GAF-182-02-01 02/07/08 PRI Construction Materials Technologies,Inc. TAS 100 GAF-332-02-01 01/17/12 TAS 100 GAF-376-02-01 10/15/12 TAS 100 GAF-153-02-01 11/30/06 Underwriters Laboratories,Inc. TAS 107 05CA48258 11/28/05 TAS 107 05CA47804 11/11/05 TAS 107 08NK02337 03/12/08 TAS 107 08NK12906 10/10/08 TAS 107 11CA47919 12/03/11 ASTM D 3161 /TAS 107 09CA41642 09/28/10 <i ASTM D 3161 /TAS 107 09CA38549 10/30/09 NOA No.: 14-1022.16 MIAMI•DADE COUNTY Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 2 of 4 EVIDENCE SUBMITTED (CONTINUED) Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D 3462 ASTM D3462 09/12/06 ASTM D 3462 08NK02337 03/12/08 ASTM D 3462 09CA21715 05/20/09 ASTM D 3462 08CA61515 07/15/09 ASTM D 3462 1 ICA47919 12/03/11 11 , LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Applications Standard RAS 115. 2. Flashing shall be in accordance with Roofing Applications Standard RAS 115. 3. The manufacturer shall provide clearly written application instruction. 4. Exposure and course layout shall be in compliance with Detail "A", attached. 5. Nailing shall be in compliance with Detail "B", attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of . manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. g} ' MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. .,1 fi NOA No.: 14-1022.16 MIAMI-DADE COUNTY " C ,..., � Expiration Date: 04/22/1.8 i , Approval Date: 02/05/15 Page 3 of 4 O' DETAIL A COURSE LAYOUT, 1st Course of Shingles 2nd Course of Shingles 3rd Course of Shingles , I 6 6" 7"— — !d 15,. Drip Edge DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 36" 1 T7 T i 00 3 LO V" END OF THIS ACCEPTANCE MIAMI•DADE COUNTY NOA No.: 14-1022.16 • Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 4 of 4 fP I'i� MIAMI-�77) MIAMI-DADE COUNTY rE M y PRODUCT CONTROL SECTION 11805 SW 26 Strcet,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION 'r(786)315-2590 F(786)31525-99 hhi NOTICE OF ACCEPTANCE (NOA) www.inianiidade.gov/econoniv Tarco Specialty Products,Inc. One Information Way, Suite 225 Little Rock, AR 72202 ,r. SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the ; expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control .Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building 4� Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the,applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and l followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official , This NOA revises NOA No. 11-0912.04 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 12-0420.02 ruarat•D,aoe CouNTY Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 1 of 16 ROOFING COMPONENT APPROVAL i' Category: Roofing Sub-Category: Underlaymentk Material: Asphalt, SBS,Polyester O � SCOPE: " , This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. PRODUCTS DESCRIPTION: Product Dimensions Test Specification Product Description 30#ASTM 3' x 72" rolls ASTM D226 Type II Asphalt saturated felt underlayment Specification Felt Manufacturing Location#1 &#2 EasyLay 3' x 1.33' 4" ASTM D226 Type 11 Sheet material comprising a polyester U. Manufacturing rolls substrate coated with bituminous coating Location#2 for use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile i' fl underlayment cap sheet. L Fiberglass Mineral 3.' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop Roofing or cold process application. Manufacturing Location#1 ASTM Organic 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Tile Underlayment Type 11 underlayment for hot mop application. Manufacturing Location#1. EasyMop SBS 3' x 36'roIIs TAS 104 Granular surfaced polyester reinforced, Manufacturing SBS modified bituminous membrane for Location#1 hot mop or cold process application. Designed as a tile roofing underlayment. , r eE �fl NOA No.: 12-0420.02 MIAMI-DADE COUNTYM Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 2 of 16