HomeMy WebLinkAboutEngineering BUILD/NGS PEAK ROOF HEIGHT va DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING MS.F,) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FFEr 0 BASIC WIND SPEED = 170 mph RISK CATEGORY#BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) RECEIVS-D SEP 091015 This is Not A Master Drawing. s" PEAK A c 20 SO.FT#" 20 SO.FT S A<50 SOFT tx A A 50 SO.FT RLE ROOF Valid Only For One Time Permit, HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE A'EGATIVf (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. ULDM4TE A.S.D. ULTIMATE A.S.D. *INDICATED DESIGN WINO PRESSURES CORRESPOND 0'- 15' 76.4 45.8 102.4 1 61.4 730 43.8 95.5 573 68.5 41.1 86.4 51.8 TO THE MAXIMUM END ZONE AND INTERIOR > 15'-2D' 80.4 48.2 107.6 64.6 76.8 1 46.1 1 100.41 60.2 72.0 1 43.2 90.8 54.5 ZONE CONDITIONS AND FOR ALL ROOF SLOPES. >20'-25' 836 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 **r S /TIER ARFA DEFINED AS. >,25'30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97.4 58.4 (1)A=[x[FOR.egg, WHERE >JO'-40' 90.7 54.4 121.4 72.8 86.6 52.0 1133 68.0 81.2 48.7 102,4 61,4 3 L=SLAT SPAN. >40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 1177 70.6 89.4 50.6 106.5 639 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 872 52.3 109.9 65.9 (2)A=5 x L FOR STORM BARS. WHERE S=SPACING BETWEEN STORM BARS L=STORM BARS SPAN. (J)A=Lx h/2 FOR REAQEB,� WHERE L=HEADER SPAN. h=STORM BAR HEIGHT(SPAN). &AD/NGS PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS& CLADDING (PSF� FOR ASCE 7-10-PEeK ROOF HEIGHT GREATER THAN 60 FFFr• (4)A=S x L FOR MULLIONS. WHERE S=SPACING BETWEEN MULLIONS BASIC WIND SPEED,= 170 mph RISK CATEGORY/I BUILDINGS L=MULLION SPAN. RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) AtAtAr PRODUCTS WHICH BEAR A MIAMI-DADE COUNTY OR A STATE OF FLORIZ A APPROVAL PEAK A c 50 SOFT A a 50 SOFT•K ROOF HEIGHT POSITIVE NEG4TIVE POSIRVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. UUIMAT£ A.S.D. >60'-70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 P�'OOf > 70'-80' 93.6 56.2 171.6 1 103.0 86.2 1 51.7 151.9 91.1 �E10 > 95.6 57. 175.2 1 VAI_ 88.0 1 155.0 193. 97.3 58.4 1 178.4 1 1074 89.7 538 1579 I 94.7 100.5 60.3 184.2 110.5 92.5 55.5 1630 1 97.8 > 120'- 140' 103.2 61.9 189.2 113.5 95.1 571 1674 100.4 > 140'- 160' 105.6 634 1936 116.2 973 58.4 171.3 102.8 > 160'- 180' 1078 64.7 197.6 118.6 99.3 59.6 174.9 104.9 BU/LD/NG SCHEMATlC11111111111fIq > 180'-.200' 109.8 65.9 201.3 120.8 101.1 60.7 176.1 106.9 ``.�` �A,T���%�'7,.,, >200'-250' 114.1 68.5 209.2 125.5) 105.2 63.1 185.1 111.1 `��Q� '"' ''•.• t/9i >250'-300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 1 y,;• \CENSE y% >Joo'-J50' 121.0 72.6 221.9 133 1 111.5 66.9 196.3 ]12J5.J 4 >J50'-400' 123.9 74.3 2271 136.3 J 14.1 68.5 200.9 _ tir 126.4 75.8 231.8 139.1 116.5 69.9 205.1 128.8 773 236.1 141.7 118.6 71.2 208.9 11111110 „�`���` No 1.)THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,BASED ON ASCE 7-10,FOR A BASIC WIND SPED OF 170 MPH,AND 2014(5th EDR10N)FLORIDA BUILDING CODE-BROWARD,PALM BEACH, MARTIN,ST.LUCIE&INDIAN RIVER COUNTIES APPLICABLE RISK CATEGORY BUILDING&EXPOSURES,IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. ASCE 7-10/ WIND PRESSURE CHART AS SHOWN 2.)THIS WIND LOAD CHART MUST BE SIGNED.SEALED AND DATED BY THIS EHG/NEER IF USED TO OBTAIN A ONE DUE BUILDING PERMIT. ROLL-UP SHUTTERS err SCALE J.)CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELEC77ON OF DESIGN WIND PRESSURE 64SED ON THIS GENERIC WIND LOAD CHART. RISK GU. II BLOCS 06/11/15 WIND PRESSURES ARE UL77MATE AND ASO.PRESSURES. ._ 'L ECOm,.1 URE CHART W/ND PRESSDA Ir VA 4.)THIS WINO LOAD CHART SHALL BE CONSIDERED/NUD IF ALTERED BY ANY MEANS. e4S/C WIND SPEED� 770 mph TBEJT TESTING&ENGINEERING COMPANY 5.)DESIGN WAD LOAD SELECTED BY THE coNmACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY e 5 X smt n.sas.WRewu canprNx D.scree EXPOSURE O,Kd a 0.85 15-189 THE CONTRACTOR OR PERMIT HOLDER(e.g.,SPREADSHEET,OPENING SCHEDULE/TAKE OFF SHEET,ETC). P4mu`(s4s EB- .Fm:[sv)an-rssr .ay.ry .qPe y� ers_ µ DRAWING No EB-0006719 WALTER A 77LL/f Jr.P.E. a0 rr-rn r/Is FLOR754 Lb. 44167 s,ralwrrts SHEET 1 OF I