Loading...
HomeMy WebLinkAboutProduct Approval 'Dt Y Florida Departments SCIS Home Lag In User Registration Hot Topics Submit Surcharge Sta & cts Publications FBC Staff BCIS Site Map Links 'Search Busines Product p`Professi PublicL COPY Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail a • FL# FL10674-R10 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Coming PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 9 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich,PE 9 Validation Checklist-Hardcopy Received Certificate of Independence FL10674 RSO COI 2015 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL* Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R10.Ddf Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party: Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10.Ddf Created by Independent Third Party: Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/ff0 employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® i?Ctiecl MW sc'curitymI"rmcl r EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate ofAuthorization#9503 l"R�N��� ® 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,Cr 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-115 One Owens Corning Parkway FL10674-R10 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 5: 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED CDmPuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report . relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: a?cS�tea-s?aas� f . •-�r",Rt�ra`.^ The facsimile seal appeadngw authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. ,�'%;`�sy�•• c. a y��J'=„i l`��:•`:: P.E.on 61/22/2025.This does not serve as an electronicallysigned Florida Registration No.59166,Florida DCA ANE1983 document signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. \,\J TRINITY 1 ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(17579628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire m are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration", Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition®Oakridge,Oakridge and WeatherGuarde HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuarde HP Hip & Ridge Shingles, ProEdge Hip&Ridge Shingles and DuraRidgeTM Hip& Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TnnityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vaud=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vazd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-115 Certificate ofAuthoritatlon X9503 FL10674-R10 Revision 5:04/22/2015 Page 2 of 6 TRINITY I ERD I 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLA710N: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshire-shingles require minimum six(6)nails per shingle. ➢ Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pars Normal Mansard or Area para Wind Areas High Wind desvanes y Mind Areal High Wind desvenes y Area pare vientosnormeies Areas vientos fuertes Area para vientos normales Areas vientos fuertes r rt. z' (B rzt'Z �� (A) t' ft. z' IBI z• �. �zt rte V Exposure 5 5/a'Exposure Siposieidn Exposiei6n 6.2.6 Minimum Nailing—Berkshire®: Saabs strip Sealantstrap La fka de seRadz La gra de seliador S Yf 9 Yf 9-Yf 8 ve o;B;Yf 9Yf S Yf 8 Yf r .. r _ 1 2" Asphafl'roofmgcement Ceimoto de techo,de Wea Exterior Research and Design,LLC Evaluation Report 037940.02.12-115 Certificate of Authorization#9503 FL30674-R10 Revision 5:04/22/2015 Page 3 of 6 QTRINI-rYIERD 6.2.7 Minimum Nailing—Devonshire—: 4r Nails r rr a• a r r — r Wz Nails ill Ten 1"Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing—Duration®,TruDefinition®Duration,Duration®Premium Cool&TruDefinition" Duration Designer Color Collection: 4:Nar1 Pattem 6 Nail bmat uannSteepSrors Esquemado4davos Pattern aareaba aiapolmiad.., SureNaVlasteriiri aiea width-. Esquema - EMmftbowdafda 9 de 6 davos aycd sopft ann d Area de damsSuieNape' •_ • • :reaSrtexa'lrbpafa _. —Y vyerta cJie�ak, artawidN alta ngg - bstmhlqq � anawl@h t7—� _ Awda .TM .� keada - T—ynI WIMP, .. �. ^it � S pbmLk i(d. -U1 5316"Exposure Nails 5Js°Exposure 6114ping.deeiiposidob IXavbs 5+,4pulp.de'exposiol¢o WV Exposure Nals5 'Exposm S*pudy:de erposlcl4u clavos gh pulg.de expodddn 6.2.9 Minimum Nailing—TruDefinition•Oakridge®,Oakridge®: 4 Nail Pattem 6'_Nail`Pattero' Esquema ion 4 davoS: Esquema con 6 c/avos t= r r r j77 Wr Exposure, Nails 55/8"Exposure Nails Eeposiddride66/Spd4 Ctavm £xposid6nAe55/spldag, 55/8"Exposure clavos 55/8"Wsura. &rpos(ci6n de 56/8 pulp Earpo#ddrr de 55/8.p'utg 6.2.10 Minimum Nailing—WeatherGuard®HP: $Ing1w61d a VNw .•A ••:• liw�wr7ir:vu�rNdlllrra C��aralfr�aifjrafe, Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate ofAuthorizadon#9503 FL10574-R10 Revision 5:04/22/2015 Page 4 of 6 QCTSRINITYIERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidge-Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 F—..PnevallingVNnd - Direction A.." TOPV7SideVietin. NailsA 'Nails:. Nails 4 t'-T Top Laminated - A 4' -Piece I I � zx Exposure. �I ul 1 1 1 1 I. 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: elm Fjg-2-High W kW F teni g;Pattdm' �4 Nib b _. inn Shingles _ rid"Discard Exce ss 14P41 't Sealant Strip," 12"•„' ' Fastennig; 5"51s” 5"Exp osume_ Di$#aince I 12 . 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingie Fastening; Fig.A 4 4 top View Prevailing WM E— Direction A - Nails .A I Nalls NOW 1 .jn I I I I f' �• AA i I i I t. � 1 I I 1 S—� t:ryosuro 5'! Exposure Exterior I 17' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FU0674-R10 Revision 5:04/22/2015 Page 5 of 6 CTSRIN ITY I ERD 6.3.6 Minimum Nailing-Pro Edge Hip&Ridge Shingles: Prevailing Standard 11 Wind Direction SeahntStrip Fattening 6°Exposure , Y 12' 1 Sealant .Fasten 7'h° 7'h° i 6"Exposure Cover Exposed ISI li Fasteners with Roof Cement 6.3.7 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: I� Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Provaiing Wir d Dirocdcn Top view �— Direction dorninanmdnmt II. voo Ian I,I Dirordfndel vientoprodornironto Vista erfor 4 I cbo n (imm Coning SumNa0' Naih 1 y o i�l i i it s��a I UM alar't"aiel� I p �12 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. H. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named OA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC Evaluation Report 037940.02.12-115 CerUfiwte ofAethor¢orlon#9503 FL10674-R10 Revision S:04/22/2015 Page 6 of 6