HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
�* t
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Roof
PROPOSED-IMPROVEMENT- LOCATION:.."_'.
Address: 2807 Carol Place Fort Pierce, FI 34946
Legal Description: HOGG'S S/D IN SEC 28-34-40 FROM NE COR LOT 20 RUN W 782.33 FT,THS 23 DEG 41 MIN E 65.36 FT FOR POB,
TH CONT SELY 65.36 FT,TH E 120 FT,TH NWLY ALG W RNV OF CAROL ST 65.36 FT,TH W 120 FT TOPOB(OR 1348-559)
Property Tax ID#: 1428-602-0047-000-6 Lot No.20
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side:
DETAILED, DESCRIPTION OF WORK:
�L°/l�ac/P ��P1uce 1 o6,-KPd 'fiYnpY1 Bout .c;VerZ Ca r-foa-r-
I��;n Howse T o ke rpe� �n as 1!5, boas .
CONSTRUCTION INFORMATION
Additionalworkto e ,performed under this permit—c ec a appy:
HVAC L_-J Gas Tank Gas Pi in _Shutters Windows Doors
Q P g Q Windows/
Doors
0 Plumbing Sprinklers E Generator Q Roof
Total Sq. Ft of Construction: 500 S . Ft.of First Floor: 1,747
Cost of Construction:$ 3,400.00 Utilities:Sewer Li Septic Building Height:
OWNER/LESSEE 'CONTRACTOR:
NameSusan Bell Name: Larry Neese
Address:2807 Carol Place Company: Larry Neese Roofing, LLC
City: Fort Pierce State:FL Address: 2801 Sunrise Blvd.
Zip Code: 34946 Fax: city: Fort Pierce State: FL
Phone No.772-465-9251 Zip Code: 34982 Fax: 772-361-6581
E-Mail: Phone No. 772-361-6580
Fill in fee simple Title Holder on next page(if different E-Mail: Iarry(W_L N roof.com
from the Owner listed above) State or County License: FL CCC1330608
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
5VP.PLEMENTAKONSTRUCTIO.N LIEN :LAW INFORMATION:,
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted orQhe jobsite
before the first inspection. If yo end to obtain financing, consult der or a rney before
comment' o k or reco our Notice of Commencement.
��y
s
_Sign=ofO Lessee/Agent Signat o ractor/License Holder
STAA STATE OF FLORIDA
COUNTY OF S}lam _ COUNTY OF S&
The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me
this day of-SP-p- 20 )S by this K day of aLGA 20�S__by
1
(Name of person cknowledging) (Name of person ack wledging)
( ignature of Notary Public-State of Florida) (Signature of Notary Public-State"of Florida)
Personally Known OR Produced Identification Personally Known OR Produced Identification
T e of Identification Produced Tif if�ation Produced
Commission No. _ ,a ,_:. LASHAHNA tNDRA No.y�s-_�- ASHAHNA ABNotary Public statet2 <<'" `B Notar Public State of Florida Y vnires ant
.•? , +'c
Revised 07/15/2014 =sr. �;= Commissrh�a#onalNotarY Assn' :J•• 'o: Commission#FF 177249
''9,;e of F��•' Bonded Ihrou9 F�F��°;•�'�� Bonded through National Notary Assn.
a
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
INITIALS
TURQUOISE Engineering, LLC
Structural Engineering, Design & Testing, CA#28948, NOA#13-0222.02
6915 Washington Rd,W Palm Beach, FL 33405/Ph. (561)804-9908/Fax(561)804-9907/e-mail:turginc@aol.com
September 02, 2015
TO: Saint Lucie County/ Building-Department
FROM: Riza N. ALTAN, P.E.
SUBJECT: Flat Roof Uplift Pressures & Base Sheet Enhanced Fastening
ADDRESS: BELL Residence /2807 Carol PI., Fort Pierce, FL 34946
CONTRACTOR:Larry Neese Roofing, Inc.
Dear Sir;
The re-roofing specifications for the flat roof area of the subject residence are reviewed
by myself. The purpose of this letter is to specify roof wind uplift pressures and
enhanced fastening requirement for the base sheet.
The one-story building is located in Exposure D area. The flat roof consists of 5/8" CDX
plywood with positive drainage. The roof mean height is 15 ft. As per 2014 Florida
Bldg. Code, ASCE 7-10, for Risk Category II, 170 MPH ultimate wind velocity in Exposure
D area, using Wind Load Factor of 0.6 for ASD; the wind pressures are determined as
follows:
Field: Pi _ - 52 psf/ Perimeter (4' wide): P2 = - 84 psf/ Corner (4'x4'): P3 = -131 psf
The proposed CertainTeed Modified Bitumen Roof System over Wood Decks (NOA
#14-0224.03) consists of mechanically attached 75-lbs GlasBase base sheet, followed by
torched-down FlintLastic GTA modified bitumen cap sheet.
The system max. design pressure of -60 psf (Deck 1I, Syst.E(3), page 14/16, Limitation #7) is
specified by tin-tagging the base sheet with 11 ga., 1'/4" long ring-shanked roofing nails,
spaced at 811o.c. along the laps and 811o.c., three rows staggered in mid-sheet.
It is required that, as per RAS 117 in order to meet the actual roof pressures, the base
sheet is tin-tagged to the existing plywood deck in the following enhanced pattern:
Zone 1: Field (Intermediate areas): @ 8"o.c., staggered three rows in mid-sheet
Zone 2: Perimeter (4' from edges): @ 6"o.c., staggered four rows in mid-sheet
Zone 3: Corner (4' from ea. side): @ 4"o.c., staggered four rows in mid-sheet
Laps: Field (4"min.): @ 8"o.c., Perimeter @ 611o.c. & Corners: @ 4"o.c.
Therefore, this letter is to certify that installation of CertainTeed Modified torched-down
Bitumen Roof System (NOA #14-0224.03) conforms to the requirements of the 2014
Florida Building Code which specifies 170 MPH ultimate wind speed for Risk Category II
in Exposure D area.
If you have any questions regarding this matter or I may 16,30M figi�istance, please
do not hesitate to call me. �.%` 'I.P•N;•;!1T.q,L°���
Sincerely, :` ;°••�.%GENSF•'•: ���
• dw
No.38521 * �
STATE OF
Riza N. ALTAN, P. 8521 . A •.
'P
Consulting Engineer ®�, O�,�•.;��OR10P•'' �``'®�
va %N
MIAMI-DARE MIAMI-DADE COUNTY
RE-JIM, CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.mianddade.gov/economy
CertainTeed Corporation
1400 Union Meeting Road,P.O.Box 1100
Blue Bell,PA 19422-0761
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#13-0204.03 and consists of pages 1 through 16.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0224.03
MIAMI-DAD;COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 1 of 16
ROOFING SYSTEM APPROVAL
Category Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: -60 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
All Weather/Empire Base 36"x 65'10"; ASTM D 4601 Type Asphalt coated,fiberglass reinforced
Sheet Roll weight: 86 lbs. H base sheet
(2 squares) UL Type 15
Flex-I-GlasTM Base Sheet 36"x 98'9";Roll ASTM D 4601,Type Modified Bitumen coated fiberglass
weight: 90 lbs. II base sheet.
(3 squares) UL Type G2
Flex-I-GlasTM FR Base Sheet 39 3/8"x 50;Roll ASTM D 6163, Modified Bitumen coated fiberglass
weight: 90 lbs. Grade S,Type I base sheet.
(1.5 squares)
Flintglas®Ply Sheet Type IV 36"x 1647";Roll ASTM D 2178 Type Fiberglass,asphalt impregnated ply
or VI weight:40/55 lbs. IV or VI sheet.
(5 squares) UL Type G1
Flintlastic STA 39 3/$" x 33;Roll ASTM D 6222, Smooth surfaced APP Modified
weight: 90 lbs. Grade S,Type H Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GTA,GTA-FR 39 3/g"x 33'3";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type II Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GMS, 39 3/8"x 34'2";Roll ASTM D 6164, Granule surfaced SBS Modified
GMS Premium weight: 1001105 lbs. Grade G,Type H Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application.
Flintlastic FR, 39 3/8"x 34'2";Roll ASTM D 6164, Fire resistant,granule surfaced SBS
FR-P Premium weight: 105 lbs. Grade G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Cap Sheet 39 3/8"x 34'2";Roll ASTM D 6163, Fire resistant,granule surfaced SBS
weight: 90 lbs. Grade G,Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications.
NOA No.:14-0224.03
QMMI-DADE COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 2 of 16
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic FR Cap T 39-3/8"x 34'2';Roll ASTM D6163 Granule surfaced SBS Modified
weight: 81lbs. Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
application.
Flintlastic FR Base T 39-3/8"x 33';Roll ASTM D6163 Modified Bitumen,coated fiberglass
Weight: 811bs. base sheet for torch application.
(1.0 squares)
Flintlastic FR Cap CoolStar 393/8,,x 34'2";Roll ASTM D 6163 Fire resistant,granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap T CoolStar 393/8,,x 34'2";Roll ASTM D 6163 Fire resistant,granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic GTA,GTA-FR 39 3/g"x 33'3";Roll ASTM D 6222 Granule surfaced APP Modified
CoolStar weight: 105 lbs. Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS/GMS 393/8,,x 34'2";Roll ASTM D 6164 Granule surfaced SBS Modified
Premium CoolStar weight: 100/105 lbs. Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
_application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P/FR-P Premium 39 3/$"x 34'2";Roll ASTM D 6164 Fire resistant,granule surfaced SBS
CoolStar weight: 105 lbs. Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating. Covered with reflective
CoolStar Coating.
Ultra Poly SMS 36"x 64'4" ASTM D 6164, Smooth surfaced SBS Modified
(2 squares) Grade S,Type I Bitumen Membrane with non-woven
polyester mat reinforcement for mop
applications.
NOA No.:14-0224.03
MIAMI•DAD,COUNTY rjw Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 3 of 16
G1asBas6rm Base Sheet 36"x 98'9";Roll ASTM D 4601 Asphalt coated,fiberglass base sheet.
weight: 69 lbs. UL Type G2
(3 squares)
PolySMS Base Sheet 393/8,,x 64'4";Roll ASTM D 4601, Modified Bitumen coated polyester
weight: 90 lbs. Grade S,Type II base sheet.
(2 squares) UL Type G2
Yosemite®Buffer Base Sheet 36"x 32'10";Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced
weight: 90 lbs. ASTM D 4897 buffer sheet.
(1 square) UL Type 30
Black DiamondTM Base Sheet 36"x 687";Roll ASTM D 1970 Self-adhering fiberglass reinforced
weight: 78 lbs. modified bitumen base sheet
(2 squares)
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
FlintBoard ISO Polyisocyanurate foam insulation CertainTeed Corporation
ACFoam-]I Polyisocyanurate foam insulation Atlas Roofing Corporation
High Density Wood Fiberboard Wood fiber insulation board Generic
Perlite Insulation Perlite insulation board Generic
DensDeck,DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels LLC
ENRGY 3,ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating,LLC
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. None N/A None N/A
NOA No.: 14-0224.03
MIAMI•DAD:COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 4 of 16
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
Factory Mutual Research Corp. FMRC 4470 J.I. 3Y8A1.AM 03/23/96
FMRC 4470 J.I. OD3A3.AM 04/04/97
FMRC 4470 J.I.2DOAO.AM 12/23/98
FMRC 4470 J.I. 1D7A4.AM 11/09/98
Underwriters Laboratories,Inc. UL 790 R11656 01/11/13
United States Testing Company ASTM D 5147 97457-4 06/03/88
ASTM D 5147 97-457-2R 12/02/87
Momentum Technologies,Inc. ASTM D 4601 AX31G8D 09/05/08
ASTM D6164 AX31G8F 06/05/09
ASTM D6222 AX3lG8G 06/05/09
ASTM D 3909/D 4897 AX31G8C 09/05/08
TrinitylERD TAS 114(J) #3504.06.01-1 06/05/01
TAS 117(B) 3503.10.06 10/10/06
TAS 117(B) 06490.04.07-R1 06/27/07
TAS 114(H) Letter 04/05/06
TAS 114 3533.01.06 01/06/06
TAS 114 3521.07.04 07/29/04
TAS 117(B)/ASTM D 6862 C8500SC.11.07 11/30/07
TAS 114 C8370.08.08 08/19/08
ASTM Physical Properties C10080.09.08-R4 03/25/10
ASTM D6164/D4798 C31410.01.11-2 01/10/11
ASTM D4601 C40050.09.12-1 09/28/12
ASTM D1970 C40050.09.12-2 09/28/12
ASTM D5147/D4798 C31410.10.10-R1 11/01/12
ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12
ASTM D4798 C31410.01.11-2A-Rl 02/21/13
ASTM D4798 C31410.12.13 12/05/13
ASTM D6222 C40050.12.13 12/05/13
PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08
Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11
ASTM D6164 CTC-068-02-01 08/09/11
ASTM D6222 CTC-070-02-01 08/09/11
ASTM D6164/D4798 CTC-093-02-01 08/09/11
ASTM D2178 CTC-122-02-01 03/13/12
ASTM D2178 CTC-123-02-01 03/13/12
ASTM D4601 CTC-127-02-01 03/13/12
ASTM D6163 CTC-128-02-01 06/11/12
ASTM D6163 CTC-129-02-01 06/11/12
ASTM D6164 CTC-132-02-01 06/11/12
ASTM D6164 CTC-162-02-01 05/09/13
ASTM D6164 CTC-161-02-01 05/09/13
ASTM D6162 CTC-183-02-01 10/02/13
ASTM D6164 CTC-190-02-01 12/02/13
NOA No.: 14-0224.03
aIAMI-DMEWMexAll
ADE COUNTY
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 5 of 16
APPROVED ASSEMBLIES:
Membrane Type: APP Modified
Deck Type 11 Wood,Insulated
Deck Description: 19/32' or greater plywood or wood plank
System Type A(1): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type
VI)mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/fe
ACFoam-II,Multi-Max FA-3,ENRGY 3,FlintBoard ISO,H-Shield
Minimum 1.5"thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 2040 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of Black Diamond Base Sheet self-adhered.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS, Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base or ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq.gravel or 300-1b./sq.slag in a flood coat of approved
mopping asphalt at an application rate of 60 lb./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FhntCoat A-
150,APOC#212 Fibrated Aluminum Roof Coating at an application
rate of 1 '/z gal./sq.
Maximum Design -52.5 psf(See General Limitation#7)
Pressure:
NOA No.: 14-0224.03
QMIAMI-DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 6 of 16
Membrane Type: SBS Modified
Deck Type 1I: Wood,Insulated
Deck Description: 19/32"or greater plywood or wood plank
System Type A(2): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type
VI)mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
ACFoam-H,ENRGY 3,ENRGY 3 25 PSI,FlintBoard ISO,H-Shield
Minimum 1.5"thick N/A N/A
Approved Perlite
Minimum%"thick N/A N/A
Approved High Density Wood Fiberboard
Minimum%"thick N/A N/A
DensDeck,DensDeck Prime
Minimum%11 thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-
I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within
the EVT range and at a rate of 20-40 lbs./sq
Ply Sheet: (Optional)One or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet
(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a
rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet(for use with a torched cap sheet
only)self-adhered.
NOA No.: 14-0224.03
Mic�ru•DaDe couN r�r Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 7 of 16
Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic
Premium GMS CoolStar, Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-
P,Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap sheet,Flintlastic FR Cap Sheet
CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT
range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar
torch adhered to base/ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-Ib./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 60 lb./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 %2 gal./sq.
Maximum Design
Pressure: -52.5 psf(See General Limitation#7)
NOA No.: 14-0224.03
QMIAMI-DAD'COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 8 of 16
Membrane Type: APP Modified
Deck Type 1I: Wood,Insulated
Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists
spaced maximum 24"o.c.
System Type A(3): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet,G1asBase or Flintglas Premium Ply Sheet(Type VI)
mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ftp
ACFoam-II,Multi-Max FA-3,ENRGY 3,FlintBoard ISO,H-Shield
Minimum 1.5"thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base: One ply of Black Diamond Base Sheet self-adhered.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS base or one or more plies of Flintglas Ply Sheet(Type
IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base
Sheet self-adhered or Flintlastic STA torch adhered.
Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base or ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 601b./sq.
2. Karnak(997 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 %gal./sq.
Maximum Design
Pressure: -60 psf. (See General Limitation#7)
NOA No.: 14-0224.03
MIAMI•DADB COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 9 of 16
Membrane Type: SBS Modified
Deck Type 1I: Wood,Insulated
Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c. at wood joists
spaced maximum 24"o.c.
System Type A(4): Anchor sheet mechanically fastened;all layer of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet,GlasBase or Flintglas Premium Ply Sheet(Type Vl)
mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ftp
ACFoam-II,ENRGY 3,ENRGY 3 25 PSI,F1intBoard ISO,H-Shield
Minimum 1.5"thick N/A N/A
Approved Perlite
Minimum%"thick N/A N/A
Approved High Density Wood Fiberboard
Minimum%"thick N/A N/A
DensDeck,DensDeck Prime
Minimum 1/411 thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 2040 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-
I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within
the EVT range and at a rate of 20110 lbs./sq
Ply Sheet: (Optional)One or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet
(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a
rate of 20401bs./sq.or one ply of Black Diamond Base Sheet(for use with a torched cap sheet
only)self-adhered.
NOA No.: 14-0224.03
Mwr n•naoe COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 10 of 16
Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic
Premium GMS CoolStar, Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-
P,Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap sheet,Flintlastic FR Cap Sheet
CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT
range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar
torch adhered to base/ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq.gravel or 300-1b./sq.slag in a flood coat of approved mopping asphalt at an
application rate of 601b./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 '/2 gal./sq.
Maximum Design
Pressure: -60 psf. (See General Limitation#7)
NOA No.: 14-0224.03
htu�r u•naue COUNTYNOA
Date: 06/19/18
Approval Date: 04/10/14
Page 11 of 16
Membrane Type: APP Modified
Deck Type 1I: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type E(1): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type
VI)mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4"and fastened with 11 ga.annular ring shank nails and approved tin
caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS, Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base/ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq.gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 60 lb./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 '/i gal./sq
Maximum Design
Pressure: -52.5 psf. (See General Limitation#7)
NOA No.: 14-0224.03
MIAM COUNTY
LUVOYMPA Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 12 of 16
Membrane Type: SBS Modified
Deck Type 1I: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type E(2): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type
VI)mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic
Premium GMS CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,
Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap Sheet,Flintlastic FR Cap Sheet CoolStar
adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate
of 20 to 40 lbs./sq. or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to
ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq.gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 601b./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 'h gal./sq
Maximum Design
Pressure: -52.5 psf. (See General Limitation#7)
NOA No.:14-0224.03
MIAMI•DAD,COUNTYFgugExpiration Date: 06/19/18
Approval Date: 04/10/14
Page 13 of 16
Membrane Type: APP Modified
Deck Type 1I: Wood,Non-Insulated
Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists
spaced maximum 24"o. c
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,GlasBase or Flintglas Premium Ply Sheet(Type VI)
mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with 11 ga.annular ring shank nails and approved tin
caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS or one or more Flintglas Ply Sheet(Type IV)or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base/ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 60 lb./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 %2 gal./sq
Maximum Design
Pressure: -60 psf.(See General Limitation#7)
QMIAMMI-DMADECOUNTY NOA No.: 14-0224.03
Expiration Date: -0224.18
Approval Date: 04/10/14
Page 14 of 16
Membrane Type: SBS Modified
Deck Type 1I: Wood,Non-Insulated
Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists
spaced maximum 24"o. c
System Type E(4): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,GlasBase or Flintglas Premium Ply Sheet(Type VI)
mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas
Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic
Premium GMS CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,
Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap Sheet,Flintlastic FR Cap Sheet CoolStar
adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate
of 20 to 40 lbs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to
ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an
application rate of 601b./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212
Fibrated Aluminum Roof Coating at an application rate of 1 %Z gal./sq
Maximum Design
Pressure: -60 psf. (See General Limitation#7)
NOA No.: 14-0224.03
MIAMI-DAD;COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 15 of 16
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 2751bf.,as
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below
275 lbf.insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official,a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field,
perimeters,and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e.perimeters,extended corners and comers).(When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0224.03
MIAMI-DA D;COUNTY Expiration Date: 06/19/18
Approval Date: 04/10/14