FL# FL10674-R10
Application Type Revision
Code Version I 2014
Application Status j Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
j-.i Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who Robert J.M.Nieminen
developed the Evaluation Report
Florida License PE-59166:
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
j Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
htW://www.floridabuilding.org/pr/pr app dtl.arpx?param=wGEVXQwtDgtBNUEY5V%2... 9/11/2015
-Florida Building Code Online iPage 2 of 2
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/22/2015
Date Validated i 04/23/2015
Date Pending FBC Approval f 04/25/2015
Date Approved 06/23/2015
'Summary of Products
jr-L# Model,Number'or Name Description
10674.1 Owens Coming A 3-t and hip&ridge
Owens
and Starkers shlrsgtes
Limits of Use F Installation Instructions
Approved for use in HVHZ:No FL10674 RIO 11 2015 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R10.pdf
Impact Resistant.N/A Verified By: Robert 1.M.Nieminen PE-59166
Design Pressure:N/A
Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. i Evaluation Reports
FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT
ISHINGLES FL10674-Rio. df
Created by Independent Third Party:Yes
i Sack Next
Contact-Us 1940 North Monroe Street.Tallaha�ssee FL 32399 Phone:850-487-1824
The State of Florida is an AAJEEO employer.Copydaht 2007-2013 State of Florida.::Privacy Statement:.Accessibility Statement-.:Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-recDrds request,do not
send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.
*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with anemail address if they have one.The emalls provided maybe used for of communication with the licensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please click ke_re.
Product Approval Accepts:
securitv.mr.Taics,
http://www.floridabuilding.org/pr/pr_app_Atl.aspx?par=7wGEVXQWtDqtBNbEY5V%2... 9/11/2015
EXTERIOR RESEARCH&DESIGN,LLC-
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,CT 06478
TRIDN' PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02-12-115
One Owens Corning Parkway F110674-RI0
Toledo,OH 43659 Date of issuance:02/06/2012
Revision 5: 04/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation
mentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described
herein have been evaluated for compliance with the 5 Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
I.AsEuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
i
CONTINUED ComPuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity]ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
A/
The facsimile seat appearing was authorized by Robert Nierninen,
is
Robert J.M.Nieminen,P.E. p.F-ono4/22/2015.This does not serve as an electromcalty signed
document Signed,seated hardmpies have been transmitted to the
Florida Registration Na.59166,Florida DCA ANE1983 Product Approval Admirdstratorand to the named dent
CER-nRcA-noN OF INDEPENDENCE:.
1. Trinity I ERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products It evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
\J1 TRINITYIERD
ROOFING SYSTEMS EVALUATION;
1. SCOPE:
Product Category. Roofing
Sub-Category: Asphalt Shingles
Compliance Statement- Owens Coming Asphalt Roof Shingles,as produced by Owens Coming,have demonstrated compliance
with the following sections of the Florida Building; Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations Conditions of
Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2 5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Ptw Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-82453 05/16/2012
UL LLC(TST9628) Physical Properties 1 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance I IICA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties I Classification letter 02/13/2014
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC(QUA962S) Quality Control Service Confirmation,R2453 Exp.08120/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic"and Supreme`are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinitioW Duration, Duration Premium Cool, TruDefinition* Duration* Designer Color Collection,
TruDefinition"Oakridge.,Oakridge"and WeatherGuard*HP are fiberglass reinforced,laminated asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles,
ProEdge Hip&Ridge Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.3 Starter Strip Plus and Starter Shingle Rail are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TnnityJERD nor Robert Nieminen, P.E. are,in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all Wind zones up to
V,W=150mph(V,1t=194mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance With FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us In all wind zones up to
V,w=150 mph(Vft=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,LLC. Evaluation Report 037940.02M-RS
Certificate of Authorkation#9503 FU0674-RIO
Revision S-04/22/2015
Page 2 of 6
J TRINITY,ERD
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are irequired for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shipgle.
i
5.4.4 Refer to Owens Coming published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall hive quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 611320-3.
6. INSTALIATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
> Berkshire*shingles require minimum five(5)nails per shingle.
➢ WeatherGuard HP shingles require minimum six(6)nails per shingle.
> Devonshire—shingles require minimum six(6)nails per shingle.
> Starter Strip Plus requires minimu 'five(5)nails per strip.
Refer to Owens Coming published information on Wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—ClassicO&Supreme:
Noriftal Mansard or Area para "onnat Mansard or Area pare
Wind Areas High Lvnii,d cf"= {And as High Wind cfairvanos y
Area pare vientas normalem Ale" Vienras Area pars vlanitar nannalas Areas Vientes!marts.
T. , r
r 2
S'Exposurs 5 SIB,EKpasure
Exposicidn 95mosleffin
6.2.6 Minimum Nailing—Berkshire":
%abfa snip Seabntst*
/L4t8a&sWW /Latkadesdki*r
0 64 00 4 1111 V 0 so 0.0--------PIS
V 9 VP 9 VP a VT8 ywr 9 Vf a Vf
2" ASptrettroormgcemontt
L
Exterior Research and Design,I.I.C. Evaluation Report 037940.02-12-RS
Certiftia;W of Authafization#9303 FU0674-RI0
Revision S:04/22/2015
Page 3 of 6
\,I TRINITY1,ERD
6.2.7 Minimum Nailing—Devonshire'":
47
P Nails
r r
T 4 B 6 Ti T T
t1�
Nail Ten 1°S of As halt Roof Cemern
6.2.8 Minimum Nailing ruDefinition®Duration,Duration®Premium Cool&TruDefinition Duration Designer
Duration®
Color Collection: _
bbmid ASleep Slop
ffitenOnaemSuegate
4 Nall Mom 6Na0.Pattern aWand1cvawmu.
Esquoara de 4 davos EWsma G3aealb epeetaea
r�afipdacepar!
SuieNallObsteningalea vddth da6davos ynSaexal�roF++a
1ArreeaadedowsSuieNaB° •
r rstaitbe t�hri 91 IImG
zmae"In
IrAwde r91,
suntla� 7z IL^'aa-,, swup
77:
um
6i�a"Exposure � 6'�d".EPOS. 1
fi56P*deexpasdeidii aaavas 6)6pu67:daex *ffin Nails Seo Eapusce
335pidg.dee+posfcd6n Cdavos 9lapdg.dee*osdrfdn
6.2.9 Minimum Nailing—TruDefrnition Oakridge°,Oakridge®:
4 Nall Pastan E 6 Nail Pattem
Esp ma ton 4 davosEsyuema con 6 davos
t
i
r
s
14- it it -� k- tr
Nails
5518".Exposrrre NOs5518".Fsposuie 6518"Exposure Clavas 6SirExposum
6rpardd6nde86/8pdg. Claves ExposiB6nde65/8pufg EiwsfddndeWepidg.
brposktdrr de 6 6/8 ping.
6.2.10 Minimum Nailing—WeatherGuard°HP:
11/Wsup VIOW
8e&Md
tom— z•� �—tl �
•::�' :t.;�;:'r' t. Falil flims
�•' GPw��z�ifl}dirr
Evaluation Report 037940.02.12-115
Exterior Research and Design,LLC. FL10674-R30
Certificate of Authorization 119503 Revision 5:04/22/2015
Page 4 of 6
'N
TRINITY ERD
6.3 Hip&Ridge Shingles.
6.3.1 Installation of Berkshire Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard HP Hip and
Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle. Installation of Duraffidgdl Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,using two!(2)nails per shingle. Refer to Owens Coming published information on wind
resistance and installation limitations,including the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with thf manufacturer's published requirements,but not less than FBC 1507.2.6 or
8905.2.5. Staples are not permitted. 1
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 ---- Fig.2
4 PMwdftVWnd
WME0011 P Tepvle. Skfe%Ae=
mail- "N Ns Nails
9 ToPL i -ed
Piece
7
U
6.3.4 Minimum Nailing—Hip&Ridge with Sealant:
ilant:
ent Fig.2.High WilidFastening Pilit"111111.1
rim Shinq&3�
I ' '
nd Diseaid
ExCeM 12—
S661ant
Strip 124!
IT
Fastening! SIA", V-ExpOstre
Distance
12
6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A 9 q TopUm
Rails
4:
W
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorisation#9303 FUG674-RI0
Revision 5-.04/2212015
Page 5 of 6
\1-J TRUNITYIER®
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
PrevaStandard
il*
Fastening
utn
Wind Direction Sedant Ship Pattern
6-Exposure
• i-F -�l —,e
12' t
t tl"ASealant
Faslen 7'/a 7W Exposure
Cover Expose
Fasts ars N
Rsof me
6.3.7 Minimum Nailing—Durallidge�m Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Coming
published installation instructions for their minimum requirements.
Top Mew
Dirood6ndalvitntoprodonimnto 191, VL-
2fCk.
al—
1
EVA U
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com
END OF EVALUATION REPORT-
Exterior
EPORT-Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 FL10674-RI0
Revikion 5:04/22/2015
Page 6 Of 6