Loading...
HomeMy WebLinkAboutDrawing Opening, I Size (Wx H) t 1. FL11413.2 47 x37 (Double Hung) 2. FL11413.2 23 x 30 �. (Double-Hung) �- 3. FL11411.2 31 x 37 6 7 8 �� (Horizontal Slider) Bed 1 Bed 2 Bed 2 4. FL11411.2 71 x 55 (Horizontal Slider) 5. FL11411.2 36,x62 I (Horizontal Slider) ��� 6. FL11411.2 52 x 62 (Horizontal Slider) 6 7. FL11411.2 52 x62 Bed 1 (Horizontal Slider) 8. FL11411.2 36 x62 (Horizontal Slider) 4 9. FL11411.2 23 x 30 9 10 �0 rN (Horizontal Slider) Liv Bath Bed 3 > m N n 10. FL11411.2 47 x50 v`ai (Horizontal Slider) a; LL `^ 11. FL11411.2 47 x50 0 u CN N (Horizontal Slider) p_ vco 12. FL11411.2 47 x50 11 v c `n (Horizontal Slider) Bed 3 0° O L � 13. FL11411.2 47 x50 3 ON >, " (Horizontal Slider) 0 Din 00 14. FL11411.2 23 x 30 (Horizontal Slider) 12 Bed 4 1 14 13 Kit Bath Bed 4 ti a N O) L_ M W Cal a '� Coo G ch U LO 2 z N r--I '� CL "T Rm "T a > LO LU 0 0 LL L . w � U COPYRIGHTE-TEMVEST.COM LU SCALE: NOT TO SCALE DATE: Sep 14,2015 PAGE DESCRIPTION: Site Plan PAGE: OF 1 1 1918 Corporate Drive Boynton Beach,FL 33426 WINDOWS Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: Vivian P Ellis Wind Zone: 160 MPH. Address: 1504 N 39th Street Exposure Category: C Fort Pierce,FL 34947 Minimum Building Dimension: 45 ft. Mean Roof Height: 10 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) IF1 Int 47 37 7 33.1 -35.9 2 Int 23 30 ! 7 33.5 -36.3 3 Int 31 37 7 33.5 -36.3 4 Int 71 55 7 31.3 -34.1 5 End 36 62 7 32.5 -42.9 6 End 52 62 7 31.7 -41.3 7 Int 52 62 7 31.7 -34.6 8 Int 36 62 7 32.5 -35.4 9 Int 23 30 7 33.5 -36.3 10 Int 47 50 7 32.4 -35.3 11 Int 47 50 7 32.4 -35.3 12 Int 47 50 7 32.4 -35.3 13 Int 47 50 7 32.4 -35.3 14 Int 23 30 7 33.5 -36.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int W 7/8"LamilG FL 11413.2 55 55 33.1 35.9 53x77 47x37 N N 2 Int W 7/8"LamilG FL 11413.2 55 55 33.5 36.3 53x77 23x30 . N N 3 Int W 7/8"LamilG FL 11411.2 55 55 33.5 36.3 74X63 31x37 N N 4 Int W 7/8"LamilG FL 11411.2 55 55 31.3 34.1 74X63 71x55 N N 5 End W 7/8"LamilG FL 11411.2 55 55 32.5 42.9 74X63 36x62 N N 6 End W 7/8"LamilG FL 11411.2 55 55 31.7 41.3 74X63 52x62 N N 7 Int W 7/8"LamilG FL 11411.2 55 55 31.7 34.6 74X63 52x62 N N 8 Int W 7/8"Lami IG FL 11411.2 55 55 32.5 35.4 74X63 36x62 N N 9 Int W 7/8"Lami TG FL 11411.2 55 55 33.5 36.3 74X63 23X30 N N 10 Int W 7/8"Lami IG FL 11411.2 55 55 32.4 35.3 74X63 47x5 0 N N 11 Int W 7/8"Lami 1G FL 11411.2 55 55 32.4 35.3 74X63 47x50 N N 12 Int W 7/8"Lami IG FL 11411.2 55 55 32.4 35.3 74X63 47x5 0 N N 13 Int W 7/8"LamilG FL 11411.2 55 55 32.4 35.3 74X63 47x50 N N 14 Int W 7/8"LamilG FL 11411.2 55 55 33.5 36.3 74X63 23x30 N N