HomeMy WebLinkAboutDrawing Opening, I Size
(Wx H) t
1. FL11413.2 47 x37
(Double Hung)
2. FL11413.2 23 x 30 �.
(Double-Hung) �-
3. FL11411.2 31 x 37 6 7 8 ��
(Horizontal Slider) Bed 1 Bed 2 Bed 2
4. FL11411.2 71 x 55
(Horizontal Slider)
5. FL11411.2 36,x62 I
(Horizontal Slider) ���
6. FL11411.2 52 x 62
(Horizontal Slider) 6
7. FL11411.2 52 x62 Bed 1
(Horizontal Slider)
8. FL11411.2 36 x62
(Horizontal Slider) 4
9. FL11411.2 23 x 30 9 10 �0
rN
(Horizontal Slider) Liv Bath Bed 3 > m N
n
10. FL11411.2 47 x50 v`ai
(Horizontal Slider) a; LL `^
11. FL11411.2 47 x50 0 u CN
N
(Horizontal Slider) p_ vco
12. FL11411.2 47 x50 11 v c `n
(Horizontal Slider) Bed 3 0° O L �
13. FL11411.2 47 x50 3 ON >, "
(Horizontal Slider) 0
Din 00
14. FL11411.2 23 x 30
(Horizontal Slider)
12
Bed 4
1 14 13
Kit Bath Bed 4
ti
a
N O)
L_ M
W Cal
a '�
Coo G ch U
LO 2 z N
r--I '�
CL "T
Rm "T a
> LO
LU 0 0
LL
L
. w �
U COPYRIGHTE-TEMVEST.COM
LU SCALE:
NOT TO SCALE
DATE:
Sep 14,2015
PAGE DESCRIPTION:
Site Plan
PAGE: OF
1
1
1918 Corporate Drive
Boynton Beach,FL 33426
WINDOWS Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: Vivian P Ellis Wind Zone: 160 MPH.
Address: 1504 N 39th Street Exposure Category: C
Fort Pierce,FL 34947 Minimum Building Dimension: 45 ft.
Mean Roof Height: 10 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
IF1 Int 47 37 7 33.1 -35.9
2 Int 23 30 ! 7 33.5 -36.3
3 Int 31 37 7 33.5 -36.3
4 Int 71 55 7 31.3 -34.1
5 End 36 62 7 32.5 -42.9
6 End 52 62 7 31.7 -41.3
7 Int 52 62 7 31.7 -34.6
8 Int 36 62 7 32.5 -35.4
9 Int 23 30 7 33.5 -36.3
10 Int 47 50 7 32.4 -35.3
11 Int 47 50 7 32.4 -35.3
12 Int 47 50 7 32.4 -35.3
13 Int 47 50 7 32.4 -35.3
14 Int 23 30 7 33.5 -36.3
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
1 Int W 7/8"LamilG FL 11413.2 55 55 33.1 35.9 53x77 47x37 N N
2 Int W 7/8"LamilG FL 11413.2 55 55 33.5 36.3 53x77 23x30 . N N
3 Int W 7/8"LamilG FL 11411.2 55 55 33.5 36.3 74X63 31x37 N N
4 Int W 7/8"LamilG FL 11411.2 55 55 31.3 34.1 74X63 71x55 N N
5 End W 7/8"LamilG FL 11411.2 55 55 32.5 42.9 74X63 36x62 N N
6 End W 7/8"LamilG FL 11411.2 55 55 31.7 41.3 74X63 52x62 N N
7 Int W 7/8"LamilG FL 11411.2 55 55 31.7 34.6 74X63 52x62 N N
8 Int W 7/8"Lami IG FL 11411.2 55 55 32.5 35.4 74X63 36x62 N N
9 Int W 7/8"Lami TG FL 11411.2 55 55 33.5 36.3 74X63 23X30 N N
10 Int W 7/8"Lami IG FL 11411.2 55 55 32.4 35.3 74X63 47x5 0 N N
11 Int W 7/8"Lami 1G FL 11411.2 55 55 32.4 35.3 74X63 47x50 N N
12 Int W 7/8"Lami IG FL 11411.2 55 55 32.4 35.3 74X63 47x5 0 N N
13 Int W 7/8"LamilG FL 11411.2 55 55 32.4 35.3 74X63 47x50 N N
14 Int W 7/8"LamilG FL 11411.2 55 55 33.5 36.3 74X63 23x30 N N