HomeMy WebLinkAboutMisc Letters A _
..
72" X 80"
1
REPLACE DOORS IN 1 OPENING ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 72 1 80 40.00 4 34.4 1 -37.6 FL15255.8 55.0 1 -55.0 FRONT ENTRY-LSMI
U-FACTOR=.30 SHGC=.24
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 13 FT 9 IN
BERGER RESIDENCE
2100 GREENBRIAR LANE DOOR REPLACEMENT PLAN
PALM CITY, FLORIDA