Loading...
HomeMy WebLinkAboutEngineering Chief Building Official September 17, 2015 St Lucie County Building Department 2300 Virginia Avenue Ft Pierce, FL 34982 Reference: Hayward Residence 11917 S. Indian River Drive Jensen Beach, FL 34957 Subject: 5-V Crimp Approval The roofer may install a Sunlast Metal "Key West Series" 5-V crimp roof system using #12 X 1-1/2"hex head Wood-zac XG fasteners @ 16" o.c. in the field (-50.5 psf) and#10 X 1- 1/2" -1/2" hex head Wood-zac XG fasteners @8" o.c., all other zones ((-189.25 psf)per FL-17701 page 3 of 4. These values far exceed the required pressures for this building and are acceptable. 5th. This fastening pattern will meet the structural criteria of the 2014 Florida Building code, Edition and chapter 30 of ASCE?-10, with a"C"exposure during a 170 mph,1t, 132 mph a,d wind event. If you have any questions,please call me at your convenience. Thank you. Dr. Qst-AA. Kuonnenn,PE 09292920 President, The Erning Corporation CA-8327 802A Muirfield Court Jupiter,FL 33458 228 Moccasin Trail West Jupiter, FL. 33458