HomeMy WebLinkAboutProduct Approval Florida Building Code Onfine,' Page 1 of 3
���
4 !
4 q,A SCIS Home log In User Registration N^Hot Topics 'Submit Surcharge Stats&Facts , Publications i FBC Staff SCIS Site Map links Search
BusinessProduct'
pproval
Professional x USER:PublicUseerr
jr
Pml„rr Approval ME=>Application Detail
FL# FL17701
Application Type New
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Sunlast Metal
Address/Phone/Email 2120 SW Poma Drive
Palm City,FL 34990
(772)223-4055
fivalidation@yahoo.com
Authorized Signature Terry Kapron
fivalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the James F. Biagi
Evaluation Report
Florida License PE-37467
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 03/02/2016
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL17701 RO COI Letter of Non affiliation03252014 00002.odf
Referenced Standard and Year(of Standard) ,Standard Year
TAS 100 1995
TAS 110 2000
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
httpJ/www.floddabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgs%2bbt23mLBHoa.SQJrpWej34g18LYQcK4uGjapvdhBJ79Q... September 15,2015
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 04/30/2015
Date Validated 08/27/2015
Date Pending FBC Approval 07/20/2015
Date Approved 09/01/2015
Summary of Products
FL# Model,Number or Name Description
17701:1 "Key West Series"5-V Crimp Steel 24GA."Key West Series"5V-Crimp metal roofing panel
24"width
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17701 RO II Sunlast Key West Series SV-Crimp 26 GA.
Approved for use outside HVHZ:Yes Steel Evaluation Report.pdf
Impact Resistant:No Verified By:James F. Biagi P.E.FL 37467
Design Pressure:+n/-189.25 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL17701 RO AE Sunlast Key West Series SV-Crimp 26 GA.
Steel Evaluation Report.odf
Created by Independent Third Party:Yes
17701.2 "Miami Series"1.75"Snap-Lock Steel 24GA."Miami Series"1.75"Snap-Lock metal roofing
panel 14"-18"width
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17701 RO II Sunlast Miami Series 1.75 24 GA Steel
Approved for use outside HVHZ:Yes Evaluation Report.pdf
Impact Resistant:No Verified By:James F Biagi P.E.FL 37467
Design Pressure:+n/a/-156.75 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL17701 RO AE Sunlast Miami Series 1.75 24 GA Steel
Evaluation Reoort.pdf
Created by Independent Third Party:Yes
17701.3 "Miami Series"1.75"Snap-Lock Aluminum.032"Miami Series"1.75"Snap-Lock metal roofing
panel 14"width
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17701 RO II Sunlast Miami Series 1.75.032 Aluminum
Approved for use outside HVHZ:Yes Evaluation ReDOrtxdf
Impact Resistant:No Verified By:James F.Biagi P.E.FL 37467
Design Pressure:+n/a/-114.25 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL17701 RO AE Sunlast Miami Series 1.75 032 Aluminum
Evaluation Renort.0
Created by Independent Third Party:Yes
17701.4 "Stuart Series"1"Nail Strip Steel 24GA."Stuart Series"1"Nail Strip metal roofing panel
16"width
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17701 RO II Sunlast Stuart Series 1.0 Nail Strip 24 GA.
Approved for use outside HVHZ:Yes Steel Evaluation Report.pdf
Impact Resistant:No Verified By:James F. Biagi P.E.FL 37467
Design Pressure:+n/a/-136.75 Created by Independent i'hird Party:Yes
Other: Evaluation Reports
FL17701 R0 AE Sunlast Stuart Series 1.0 Nail Strip 2.4 GA.
Steel Evaluation Report.ndf
Created by Independent Third Party:Yes
Contact 11s::194n North Monme Sheet,Tallahassee Fl 37399 Phrne:B50-4117-1874
The State of Florida Is on AA/EE0 employer.Capoght 7nn7-7813 State of Finrida.::ErhMQLcaaMM nt::Arreccihpfif Statement;:RPfimd CtatPmpnt
Under Florida law,email addresses are public records.If you do not want your a-mal address released In response to a public-records request;do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emals provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provlde the Department with an email address which can be made available to the public To determine if you are a licensee under chapter 455,F.S.,
please dick here
Product Approval Accepts:
httpJ/www.11oridabuilding.org/pr/pr app dtl.aspx?param--wGEVXQwtDgs%2bbt23mL8HoaSQJrpWej34gl8LYQcK4uGjapvdh8J79Q... September 15,2016
i
Sunlast Metal Inc
#FL 17701.1
EVAWATION REPORT
OF
SUNLAST METAL Ivaco
"Key West Series"
5V Metal Roof Panel over 15/32"Plywood
Metal Roofing Assembly
For
r � . Elorida��.State
�.uProduct
p*Approval
y Rotao y� n o % 4 L 1 701 .1
Z2 "Pic V " " "• Florida Building Code 2014
n , _ ..,,' ^� Per Rule 6IG20-3
HVHZ
i `� ot�i •t tti �_r�'.psi: w fi42 .
CaQgory: Roofing
=-• 3.4rl�j—Category
'� Metal Roofing
?3 d1: %gip -=r F,L-;r:
09uct: "Key West Series"5V Metal Roof Panel
y
6;Ehi<ir• e''%i 'ia" �sC>. ':,:. i3;i4`% -S !`0•aeriaf: Steel
ars�elThickness: 26-ga
l Utidth: 24"
": '== ; _ _ r_•.� �: �. ti:. "spd 1 1 Seam: Lap(See Table)
C i."�le;�. r��.�L�.^:�!�•s'1. ol�"��:'�;�_ii:. ::aeY:;G1'??:%:'
` � c.� r n al rt'1Vpe: Wood Deck(35/32"min.)
_=ai�;i.•`'' ...� ail;{s''i= :'e ?i:�i-z mss-Se�- u
13iia-..:-YSi v'`ii - 'ts-ti...'vNS•Fa"s�:`-iii li
;: _•mak_:, _ _ _x»�.1- �`•3i-:'.,. ,..t:�
n ..ss7cir"e�vi-. •c[Cc•�i4:'.i+�=+ii'
G'..v u3'ge:t•:Ji::��d:e !
Product Manufacturer,
i' 1i Suniast Metal Inc.
2120 SW Poma Drive
x----� ' Palm City, FL 34990
Engineer Evaluator:
James F.Biagi P.E.FL#37467
Q 1915 NE 45t'St,Suite#107
Fort Lauderdale,FL 33308
Validator:
Locke Bowden, P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents:
Page I of 4
i
Sunlast Metal Inc
#FL 17701.1
Evaluation Report Page 1-4
Manufacturer: Sunlast Metal-Inc.
Product Name: "Key West Series" 24"5V Panel
Product Category: Roofing
Product Sulo-Category: Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3
Panel Description: "Key West Series" 24"26-GA Steel 5V Roof Panel mechanical attached to
single layer%2" (15/32") min.wood deck with screws.
Panel Material/Standards: Material: Steel
Yield Strength 55 ksi minimum
Corrosion Resistance: Material shall comply with Florida Building Code
Section 1517.6 for HVHZ
Panel Dimensions: Thickness: 26-ga Steel
Width: 24"
Rib Height: 5/8"
Support Type: Wood Deck 15/32" min.(Design of support not included in this
evaluation)
Slope Range: Minimum slope shall be 2:12 or greater in accordance with
Manufacturers recommendations and in accordance with FBC section
1515.2
Underlayment: Shall conform to FBC 2014
Fire Classification: Fire Classification is not within the scope of this evaluation.
Attachment Components: Roof Panel Fastener:
Field Zone Fastener
Size: #12 X 1-1/2"(3/16"minimum penetration through support)
Tvpe: Wood-Zac XG Fastener, Hex-Head w/Neoprene washer
woodscrew
Corrosion Resistance: Per FBC section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B 18.6.1
Corner Zone Fastener
Size: #10 x 1-1/2"(3/16"minimum penetration through support)
Tvpe: Wood-Zac XG Fastener, Hex-Head w/Neoprene washer
woodscrew
Page 2 of 4
t
Sunlast Metal Inc
#FL 17701.1
Corrosion Resistance: Per FBC section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B 18.6.1
Insulation: Optional: Rigid insulation board, 3" maximum thickness and shall comply
with FBC 2014 section 1508.2
Installation: Install per manufacturer's recommended details and RAS 133.
Design Uplift Pressure:
Table A
Maximum Design Pressures
Roof Areas Field Perimeters and Corners
Maximum Design Pressures -50.50 psf -189.25 psf
Screw Spacing 16"o.c. 8"o.c.
Fastener Size #12 #10
*Maximum Design Pressures include 2:1 Safety Factor
QUALITY ASSURANCE: The manufacturer has demonstrated compliance of the roof panel products in
accordance with the Florida Building Code and Rule 61G20-3 for manufacturing
under quality assurance program audited by an approved "Quality Assurance
Entity"through KEYSTONE CERTIFICATION, INC. (FBC ID#QUA 1824)
Code Compliance: This product described herein has demonstrated compliance with the FBC 2014
section 1523.6.5.2.4.1
Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code, as related to Rule 9N-3.
System Limitations: The required wind loads shall be determined for each project per FBC, 2014.The
maximum fastener spacing herein shall not be exceeded.Any rational analysis
computation shall be prepared by a qualified design professional and in
compliance with FBC 2014.
Reference Data:
Entity Report No. Standard Year
Architectural Testing Inc. (TST 1527) 0412-1017-05 TAS 125 2003
Architectural Testing Inc. (TST 1527) SFMS-001-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) AKZC-001-02-01/05 TAS 110 2000
PRI Construction Materials Technologies(TST5878) AKZC-001-02-01/05 ASTM B 117 2002
Akzo Nobel Coatings, Inc. Lab Form ASTM G 153
Page 3 of 4