HomeMy WebLinkAboutDrawing pE1�I�p SEP 2 4 '015
. RR
Do
74" X 96"
1
REPLACE DOOR AND SIDELIGHTS IN 1 OPENING ONLY.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 74 1 96 49.33 1 4 34.6 1 -37.8 FL8228.10 45.0 1 -45.0 FRONT ENTRY
U- FACTOR= .26 SHGC = .20
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 15 FT 1 IN
RUNYON RESIDENCE
7006 MAIDSTONE DRIVE DOOR REPLACEMENT PLAN
PORT ST. LUCIE, FLORIDA