Loading...
HomeMy WebLinkAboutMisc Letters FILECOPY Company: The Home Depot At Home Services Job Description: Replacing 15 windows size 1 CCC Prepared By: Amber ; Client Name: Thompson Project Number: 8552292 Version 10 0:; '� �/ 'w./� - ,r(c)201 Structures lnteinauo al LL.Cn- ,a;.,»s xv'.;�; �;.�:,, ..�,�._:.,4�. INIQ- r!:(�L ar ;. -.r ,-r, a�e ` Conforms with ASCE 7 10: s:-+rx.x DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 12 Risk Category 2 Building Width(ft) 62 Exposure Category D Building Length(ft) 32 Directionality Factor 0.85 Roof Slope (x:12) 3 Internal Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 9700-1PNL BI 5 5 54 51 38.9 -51.0 2 9700-1PNL BI 5 5 54 51 38.9 -51.0 3 9700-SH BI 5 5 36 38 40.6 -54.4 4 9700-1PNL BI 5 5 73 51 38.1 -49.4 5 9700-1PNL BI 5 5 73 51 38.1 -49.4 6 9700-SH BI 5 5 36 38 40.6 -54.4 7 9700-1PNL BI 5 5 73 51 38.1 -49.4 8 9700-SH BI 5 5 36 26 40.6 -54.4 9 9700-SH BI 5 5 36 26 40.6 -54.4 10 9700-SH BI 5 5 36 38 40.6 -54.4 11 9700-SH BI 5 5 36 38 40.6 -54.4 12 9700-SH BI 5 5 36 38 40.6 -54.4 13 9700-SH BI 5 5 36 38 40.6 -54.4 14 9700-1PNL BI 5 5 73 38 38.9 -50.9 15 9700-1PNL BI 5 5 73 38 38.9 -50.9 Width of End Zone(a)in feet= 3.2 5 h 0 5 1 O 4 � p Y i �Q 5 5 - Y STRUCTURES INTERNATIONAL,LLC F:.:,vdirx3 s:rnr„oxk,7rs1�-Ccmp7sx�'r ale?ixi,. 9/21/2015 10:10 AM