EVALUATIONREPORT
Johns Manville Corporation Evaluation Report J9340.07.08-1-RS
P.O.Box 5108 FL4205-118
Denver,CO 80217 Date of Issuance:07/16/2008
Revision Sr 0-4'/28/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials:in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product_underthe Florida Building Code. The products described herein have been evaluated for compliance with
the 5th Edition(2*014)Florida Building Code sections noted herein.
.DESCRIPTION: Johns Manville Roof Insulation BoartJs
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report
relative to updated:Code requirements with each Code Cycle,
ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINITY)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
.r%SCo.3?CwR
Robert J.M.Nieminen P.E. p,^ • ly The facimilie seal appearing was authorized by Robert Nieminen•P.E.
05.
P.E.
iQ�a1.7'.—
documon ent.Signed,'s ds nsealed hadroples have been transmitted to the
Floridaserve as an electronically signed
Registration No.59166,Florida DCA ANET983
'.����••'r't^t" Product Approval Administrator and to the named client
CERTIfl[ATION'Of INDEPENDENCE:
1. Exterior Research&Design,LLC.d/b/a Trinity[ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in
any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, I.I.C. d/b/a TrinitylERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4_ Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P-E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
09/21/2016 11,07 4641 P.019/019
From:
-,JTRINITY IERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Insulation
Compliance Statement: Johns Manville Roof insulation, as produced by Johns Manville Corporation, has demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Pro perw Standard Year
1509.1,2603.313),2.603.4.1.5 Internal Fire FM 4450 1989
T1508.2 Physical Properties ASTM 0728 2005
T1508.2 Physical Properties ASTM C1289 2008
2603.3 Flame Spread ASTM E84 2009
3. REFERENCES-
Entity Examination Reference Date
ERD(TST15049) Physical Properties 00252.10.02 10/31/2002
ERD(TST6049) Physical Properties 00251.10.02 11/04/2002
ERD JTST6049) Physical Properties 10681,04.06-R1 05/17/2006
I'M Approvals(TST1867) FM 4450 1J4A3AM 04/11/1985
FM Approvals(TST1867) FM 4450 OK4A9.AM 10/11/1985
I'M Approvals(TST1867) FM 4450 3004299 03121/2000
FM Approvals(TST1867) ASTM E94 3023546 11/04/2005
FM Approvals(TST1867) FM 4450 3034810 09/10/2009
PRI(TST5878) ASTM 0729 JMC-104-02-01 01/11/2013
Miami-Dade(CER1592) HVHZ Compliance 14-1015-08 01/15/2015
UL LLC(QUA9625) Quality Control Service Confirmation Exp.10/22/2016
4. PRODUCT DESCRIPTION:
The following insulations are mechanically attached or adhered to Approved substrates using fasteners, stress plates and
adhesives,as outlined in the Roof System Product Approval.
> ENRGY 30,ISO 31 and ValuTherm are rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded
between two fiber Blass reinforced facers meeting ASTM 01289,Type 11,Class 1,Grade 2. Available in flat stock or tapered
boards.
> ENRGY 30 ZS PSI and ValuTherm 2S PSI are rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded
between two fiber glass reinforced facers meeting ASTM C1289,Type 11,Class 1,Grade 3. Available in flat stock or tap6red
boards.
ENRGY 3®Plus is a rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded in the foaming process
to Y,"thick high-density wood fiberboard on one side and a fiber-reinforced facer on the other meeting ASTM C1289,Type IV.
Available in flat stock or tapered boards.
Fesco FoamO is a rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded in the foaming process to
Fesco Laminator Board on one side and a fiber-reinforced facer on the other meeting ASTM C1299,Type 111. Available in flat
stock or tapered boards.
DuraFoamO is a rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded in the foaming process to
DuraBoard"on one side and a fiber-reinforced facer on the other. Available in flat stock or tapered boards.
> InvinsaFoam6 is a rigid roof insulation composed of a closed cell polyisocyanurate foam core bonded in the foaming process
to Invinsa" Roof Board on one side and a fiber-reinforced facer on the other meeting TAS 110. Available in flat stock or
tapered boards.
> NaillboardO is a rigid roof insulation composed of a closed cell polylsocyanurate foam core bonded in the foaming process to
7/16"or 5/8"oriented strand board(C)SB)one side and a universal glass-reinforced facer on the other meeting ASTM C1289,
Type V.
Exterior Research and Design,LLC. Evaluation Report 39340.07.MI-RS
Certocate Of Authorization 99503 FL4205-R8
Revision 5:04/29/2015
Page 2 of 3
From: 09/21/2095 10:44 #640 P-002/019
ti
,-J'[ N9 ERD
Y Vented Nailboard"I is a rigid roof insulation composed of a closed cell polyisocyanurate foam core attached with spacers to
7/26"or 5/8"oriented strand board(OS6)one side and a universal glass-reinforced facer on the other meeting ASTM C1289,
Type V.
D FescoO Board and FescoO Board HD are homogenous insulation boards,composed of expanded perlite,blended with selected
binders and fibers meeting ASTM C728. The top surface is sealed with TopLocv coating to prevent excessive absorption of
asphalt during the installation process. Available in fiat stock or tapered boards.
DuraBoard° Roof insulation is a high-density,low-thermal rigid insulation board,composed primarily of expanded perlite
with reinforcing cellulosic fibers and selected binders meeting ASTM C728.
Y %"Retro-Fit"Board is a high-density board composed of expanded perlite and cellulosic fibers meeting ASTM C728. The top
surface is sealed with TopLocm coating for use in bituminous applications.
Y RetroPlus'"Roof Board is a high-density board composed of expanded perlite and cellulosic fibers meeting ASTM C728. The
top surface is sealed with Toploc"coating for use in bituminous applications.
r InvinsW"Roof Board and invinsa'"FR Roof Board are high-density polylsocyanurate bonded to mineral-surfaced,fiber glass
reinforced facers meeting ASTM C3289,Type II,Class 2.
5. WiTATIONS:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZ jurisdictions.
5.3 Roof assemblies are approved under specific roof cover Product Approvals.
5.4 Refer to roof system Product Approval for use and installation of Johns Manville Roof Insulation Boards. if a Johns
Manville Roof Insulation Board is not listed in the roof system Product Approval,a request may be made to the AHJ for
approval provided that internal fire,external fire and wind uplift resistance of the roof assembly are addressed through
testing by an accredited testing facility.
5.5 Use of fully-adhered hot bituminous membrane roof systems atop polyisocyanurate insulation boards requires use of a
coverboard atop the insulation.
5.6 The maximum size for bonded applications of polyisocyanurate boards is 4 x 4 ft.
5.7 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C.Rule 61620-3.
6. INSTALLATION:
Johns Manville Roof insulation Boards shall be installed in accordance with Johns Manville Corporation published installation
instructions,coupled with attachment requirements set forth in the roof system Product Approval documentation.
7. BulU m PERMIT REQuiREMEWS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61620-3 QA requirements.
9. QUALITY ASsuRANcE ENTITY:
UL LLC-QUA9625;(414)248-6409;karen.buchmann@us.ul.com