Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 Y A-�� Iorida Departments; BCIS Home i Log In I User Registration Hot Topics I Submit Surcharge Stats B&Facts : Publications I FBC Staff BCIs Site Map I Links Search Busines %/'� l-`-` aProduct ApprovalProfessional USER:Public User Regulation Product Approval Menu>Product or Aoolicatlon Search>Aoolication List>Application Detail •� ��s��'" FL# FL11743-R4 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer NATURAL LIGHT ENERGY SYSTEMS Address/Phone/Email 10821 N.23rd Ave. PHOENIX,AZ 85029 (813)909-1956 bolsonl@tampabay.rr.com Authorized Signature Kelly Joya kelly@nitubular.com Technical Representative Gregg Vincent Address/Phone/Email 10821 N.23rd Ave. Phoenix,AZ 85029 (602)485-5984 gvincent@nitubular.com Quality Assurance Representative Mark Orszulak Address/Phone/Email 10821 N.23rd.Ave. Phoenix,AZ 85029 (602)485-5984 Mark@nitubular.com Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute, Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL11743 R4 Eouiv EER 1842 Rev3 41S-OS02 NLS- TubularSkvliaht ss.Ddf https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquzHEnMXJwexy8HB... 9/9/2015 Florida Building Code Online Page 2 of 3 r, e Product Approval Method Method 1 Option A Date Submitted 07/09/2015 Date Validated 07/14/2015 Date Pending FBC Approval Date Approved 07/23/2015 Summary of Products FL# Model,Number or Name Description 11743.1 10"Skylight Solar Skylight-10"dome,single glazed,pitched,self- Flashing tubular skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11743 R4 C CAC NI005337 01-R5.odf Approved for use outside HVHZ:Yes FL11743 R4 C CAC OA-Natural Light-02-12.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+80/-80 02/28/2016 Other: Installation Instructions FL11743 R4 II NLS0007 REV B ss.odf Verified By: Robert J.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL11743 R4 AE PER 1842 Rev3 415-0502 NLS- TubularSkylight ss.odf Created by Independent Third Party:Yes 11743.2 13"Skylight Solar Skylight-13"dome,single glazed,pitched,self- Flashing tubular skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11743 R4 C CAC NI005337-R5.odf Approved for use outside HVHZ:Yes FL11743 R4 C CAC OA-Natural Light-02-12.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +80/-80 02/28/2016 Other: Installation Instructions FL11743 R4 II NLS0007 REV B ss.pdf Verified By: Robert J.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL11743 R4 AE PER 1842 Rev3 415-0502 NLS- TubularSkylight ss.odf Created by Independent Third Party:Yes 11743.3 18"Skylight Solar Skylight-18'dome,single glazed,self-flashing tubular skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11743 R4 C CAC NI005336 01-RS.gdf Approved for use outside HVHZ:Yes FL11743 R4 C CAG OA-Natural Light-02-12.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +80/-80 02/28/2016 Other: Installation Instructions FL11743 R4 II NLS0007 REV B ss.odf Verified By: Robert J.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL11743 R4 AE PER 1842 Rev3 415-0502 NLS- TubularSkylight ss.ndf Created by Independent Third Party:Yes 11743.4 21"Skylight Solar Skylight-21"dome,single glazed self-flashing tubular skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11743 R4 C CAC NI005336-R7.gdf Approved for use outside HVHZ:Yes FL11743 R4 C CAC OA-Natural Light-02-12.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+80/-80 02/28/2016 Other: Installation Instructions FL11743 R4 II NLS0007 REV B ss.gdf Verified By: Robert J.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL11743 R4 AE PER 1842 Rev3 415-0502 NLS- TubularSkvlight ss.odf Created by Independent Third Party:Yes Back Next https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquzHEnMXJwexy8HB... 9/9/2015 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: N1005337-R5 ���� o�' di�,;'�'• = DATE: 02/12/2004 o; CERTIFICATION PROGRAM: Structural COMPANY: Natural Light CODE: N-557-I. REVISION DATE: 02/01/2012 i To verify that the"Notice of Product Certification" is valid,please visit w�vw.NAMfCcrtitication.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. Please review and advise NAMI ifany corrections are required to this document.. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Natural Light Energy Systems Model "Natural Light/SolarSkylitc 13" 10821 North 23"' Avenue Single Glazed, Pitched, Self-Flashing Phoenix, AZ 85029 Tubular Skylight Dome: 0.177" Optix Acrylic Plastic SPECIFICATION PRODUCT RATING, ASTM E330-97/TAS 201/202/203-94 Design Pressure: +80/-80 psf ASTM E1886/E1996 Missile Impact Rated-Passed as Stated ASTM E331-00/283-99 Product Tested By: Hurricane Testing Laboratoy, Inc. lZeport No: 0290-0318-02 (Specimen 94 A-C) Expiration Date: February 28, 2016 j Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 m m NATURAL LIGHT ENERGY SYSTEMS cq ID 00 SELF FLASHING — SINGLE GLAZED TUBULAR SKYLIGHTS � U LL INSTALLATION ANCHORAGE DETAILS 0 ,- o W r az < B CIL �w GENERAL NOTES: GENERAL NOTES(CONT.) INSTALLATION NOTES: INSTALLATION NOTES: ca ¢ 2 1.THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED 9.DOME IS GLAZED INTO DOME RING BY FIRST APPLYING A 2.INSTALL FLASHING TO PREPARED ROOF DECK 3.APPLY A BEAD OF GEOCELL 2300 TRIPOLYMER SEALANT TO COMPLY WITH THE CURRENT EDITION OF THE BEAD OF GEOCELL 2300 TRIPOLYMER SEALANT INTO ASSEMBLY BY LAYING A BED OF CONTINOUS BEAD OF TO EACH EXPOSED FASTENER HEAD USED IN FLASHING FLORIDA BUILDING CODE(FBC)REQUIREMENTS DOME RING AND THEN INSERTING DOME.DOME ENGAGES GEOCELL 2300 TRIPOLYMER SEALANT BETWEEN ROOF INSTALLATION. co o v+ INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ) INTO DOME RING A MINIMUM OF 1/4 INCH. DECK AND FLASHING AND A SINGLE ROW OF#10 X 1 1/2 S o LL FOR WIND ZONE 4,MISSILE LEVEL D AT THE DESIGN INCH PH SMS SPACED NO MORE THAN 81NCHES ON 4.APPLY GEOCELL 2300 TRIPOLYMER SEALANT ACCORDING Lo o i O PRESSURE(S)STATED HEREIN. 10.WHEN APPLICABLE AND IN ACCORDANCE WITH THE CENTER AROUND THE ENTIRE CIRCUMFERENCE OF TO MANUFACTURERS INSTRUCTIONS. CURRENT EDITION OF THE FBC DISSIMILAR METALS THE FLASHING, y U)Lu 2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED INCLUDING FASTENERS THAT MAY COME INTO CONTACT 5.IF ROOF DECKING IS LESS THAN 5/8 INCH THICK,ANCHOR UPON SIGNED AND SEALED TEST REPORTS#HTLLu WITH ALUMINUM SKYLIGHT FRAMING WOOD SHALL HAVE 2.1 MINIMUM 12 SCREWS REQUIRED FOR 21"AND 18" SPACING MUST BE DECREASED TO 5 3/8 INCHES g O o 0290-0318-02/0290-0604-02 AND ASSOCIATED BEEN PROTECTED. SKYLIGHT AND MINIMUM 10 SCREWS FOR 13"AND MAXIMUM ON CENTER AROUND THE ENTIRE PERIMETER T W m z LABORATORY STAMPED DRAWINGS. 10"SKYLIGHT. OF THE FLASHING. y Z N'0 vi INSTALLATION NOTES: 2.2 IF MAXIMUM O.C.SPACING OF 8'CANNOT BE r W F- F m 3.THE SKYLIGHT HAS BEEN TESTED IN ACCORDANCE WITH MAINTAINED,INCREASE QUANTITY OF FASTENERS. 6.PRODUCT ANCHORS SHALL BE AS DESIGNATED AND w Q m W g > z THE HIGH VELOLCITY HURRICANE ZONE(HVHZ) 1.INSTALL DOME RING INTO FLASHING USING#8 PH SMS 2.3 IF MINIMUM EMBEDMENT SHOWN IN ANCHOR LOCATED AS SHOWN ON THE INSTALLATION DRAWINGS. w p Q y REQUIRMENTS OF TAS 201,TAS 202 AND TAS 203 AS WITH SUFFICIENT LENGTH(3/4'SCREWS SHOWN FOR SCHEDULE CANNOT BE MAINTAINED USING#10 X 1 ANCHOR EMBEDMENT AND EDGE DISTANCE EXCLUDE w� o = REQUIRED BY THE CURRENT EDITION OF THE FLORIDA ILLUSTRATION)FOR SCREWS TO PROTRUDE THREE 1M'LONG SMS,SCREW LENGTH SHALL BE WALL FINISHES INCLUDING,BUT NOT LIMITED TO h a X 0 Z BUILDING CODE AND DOCUMENTED IN SIGNED AND THREAD PITCHES BEYOND FLASHING.LOCATE SCREWS INCREASED. SHEATHING,UNDERLAYMENT AND SHINGLES. SEALED TEST REPORTS#HTL 0290-0318-02/0290-0604-02 ONE AT EACH QUARTER POINT OF DOME RING.DOME nr=Z Q O i l AND ASSOCIATED LABORATORY STAMPED DRAWINGS. RING OVERLAPS FLASHING A MINIMUM OF 1 1/4 INCH -t AROUND ITS CIRCUMFERENCE. TABLE OF CONTENTSP 9 4.PLASTIC GLAZING REQUIREMENTS PER THE CURRENT p CD;� j Lu W EDITION OF THE FBC,HAVE BEEN EVAULATED AND ARE IN SHEET REV. DESCRIPTION Q =w COMPLIANCE AS DOCUMENTED IN PRODUCT EVALUATION DESIGN PRESSURE RATING(PSF) IMPACT RATING1 z y 0 y REPORT NO.1842. A GENERAL NOTES,INSTALLATION NOTES,D.P.CHART AND ANCHOR SCHEDULE. g $„F1 180.0 LARGE MISSILE LL a&H 5.SKYLIGHT ASSEMBLY MOUNTING REQUIREMENTS PER IMPACT 2J THE CURRENT EDITION OF THE FBC HAVE BEEN A 21'DIAMETER ELEVATIONS,SECTIONS AND ANCHOR INSTALLATION � EVAULATED AND ARE IN COMPLIANCE AS DOCUMENTED 3 A 18”DIAMETER ELEVATIONS,SECTIONS AND ANCHOR INSTALLATION IN PRODUCT EVALUATION REPORT NO.1842 AND SHOWN _ ON THIS PRODUCT EVALUATION DOCUMENT. 4 A 13'DIAMETER ELEVATIONS,SECTIONS AND ANCHOR INSTALLATION 6.ADEQUACY OF THE EXISTING STRUCTURAL FRAMING AS 5 A 10"DIAMETER ELEVATIONS,SECTIONS AND ANCHOR INSTALLATION A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE STRUCTURE IS THE RESPONSIBILITY OF ANCHORSCHEDULE THE ENGINEER OR ARCHITECT OF RECORD. MANUFACTURER EDGE DISTANCE ANCHOR CAPACITIES 7.SITE CONDITIONS THAT DEVIATE FROM THE DETAILS OF SUBSTRATE TYPE SIZE AND/OR EMBEDMENT(IN)til (7) THIS DRAWING REQUIRE THE FOLLOWING: SPECIFICATION (IN) BASED ON 7.1.IN NON-HVHZ,FURTHER ENGINEERING ANALYSIS BY A LICENSED PROFESSIONAL ENGINEER OR REGISTERED ASME BI 8.6.4 WOOD VVITH AMINIMUM Robert J.Amoroso,P.E. ARCHITECT. ALUMINUM FLATHEAD NO.10 CTAPPINGSCREW) 1-1/4" 3/8" SPECIFIC GRAVITY OF 0.42 Florida P.E.No.49752 7.2.IN HVHZ,FURTHER ENGINEERING ANALYSIS BY FLASHING TO WOOD LICENSED PROFESSIONAL ENGINEER OR REGISTERED (SMS) AND 1100-0 ALUMINUM Digitally signed ARCHITECT AND ONE TIME APPROVAL FROM MIAMI-DADE COUNTY IS REQUIRED. by Robert J. ALUMINUM DOME ASME 818.6.4 SCREW TO Amoruso 8.IN HVHZ AREAS,USE OF AN APPROVED IMPACT PROTRUDE THREE ,�jPbF5�q4,, RINGTOALUMINUM PAN HEAD NO.8 (fAPPINGSCREW) NIA 1100-0 ALUMINUM ;omE?Ct6e se°A�; DN:cn=RobertJ. PROTECTIVE SYSTEM COMPLYING WITH THE HVHZ ) THREAD PITCHES FLASHING (SMSAmoruso,o,x - REQUIREMENTS OF THE FBC IS NOT REQUIRED FOR THE BEYOND FLASHING "�, ¢;ou=PTC Product PRODUCT(S)HEREIN.IN NON-HVHZ AREAS WHERE =$:•.—E ar •y'�p Design Group, USE E OFOAN IMPACT PROTECTIVE SYSTEM COMPLYING RNE DEBRIS PROTECTION REQUIREMENTS IST NOTES: ss�o"Ha£Gr�` email=robert@pt WITH THE FBC REQUIREMENTS FOR WINDBORNE DEBRIS �cnhx,�xM' 1)FHSMS=PAN HEAD SHEET METAL SCREW c-corp.com,c=U$ REGIONS IS NOT REQUIRED FOR THE PRODUCT(S) HEREIN. 2)FOR TAPPING SCREWS IF SPLITTING IS A CONCERN,DRILL 3/32"PILOT HOLE FOR NO.10 FOR WOOD SG>0.5. Date:2015.07.09 16:16:52-04'00' 8" MAX. O.C. DOME m .177"HIGH IMPACT #10 x 11/2" o - a F DOME RING OPTIX ACRYLIC AC2 0 — PH SMS TYP. 4 STS-21 OTR �_ 0 1100-OALUMINUM 11.60LL 0.063"THK. H O< o U ro c —Wi w z a #8 X 3/4"SMS 0 <o GEOCEL 2300 TYP(4) a E TRIPOLYMER G I I SEALANT 4.0"- 0.44" .0 4.0 GEOCEL 2300 m 5 STS-21 OTR 10.44" TRIPOLYMER 1100-0 ALUMINUM SEALANT BETWEEN S 0.07"THK. FLASHING&ROOFING c�Z .69 0 �O ooz 7.25" .. #10 X 1 1/2" 1�a DECKING PH SMS TYP. SN BY OTHERS r w mo ROOFIN 23.25"0 }w o=)w >` `� ASSEMBLY Z m #8 SMS Located BY OTHERS z o In @ Qtr. Points N X 0z SECTION (Zw�F 0 1!) F0" SLOPED ROOF FLASHING o a uzig q�® NATURAL LIGHT 10" Z o ELEVATION &ANCHOR LAYOUT Z UK) 1 EXTERIOR VIEW DOME w� f��g .177"HIGH IMPACT c GEOCEL 2300 OPTIX ACRYLIC AC2 - TRIPOLYMER CLASSIFICATION SEALANT 1 1.6" NOA 09-0219.11 DOME RING STS-21 OTR 1100-0 ALUMINUM STS-21 OTR 0.080 THK. #8 X 3/4"SMS 1100-0 ALUMINUM 4.0" TYP(4) 0.063"THK. ROOFING - GEOCEL 2300 ASSEMBLY 10.49" 6 0 TRIPOLYMER Robert J.Amoroso,P.E. BY OTHERS SEALANT BETWEEN Florida P.E.No.49752 FLASHING&ROOFING Digitally signed DECKING by Robert J. Amoroso #10 X 1 1/2" 23 25" BY OTHERS oQ�i�EHs?%9 DN:cn=Robert J. TT PH SMS TYP. ' E``' Amoruso,o, 24" O.C. ``� �r��e '-ou=PTC Product iA E OF W. FRAMING BY OTHERS o :=W; Design Group, G ROOF FRAMING SECTION °•"••••Er�:•°� email=robert@pt 10" FLAT ROOF FLASHING ONA „ c-corp.com,c=US Date:2015.07.09 16:17:59-04'00' e