Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMI DA09 MIAMI-DADS COUNTY PRODUCT CONTROL,SECTION 11805 SW,26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION 'T(7:86)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) ww,i,.n,iamidade.eov/ecoaorov Interwrap,Inc. 32923 Mission Way Mission,BC,Canada V2V4E4 SCOPE: This NOA is being issued under•'the applicable rides and regulations-governing the,use of construction materials.The documentation submitted has:been reviewed and accepted by Miami-Dade County RER-,Product Control Section to be used in Miami Dade County and other areas;where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade. County Product. Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miaini Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted, manner, the .manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use ofsuch product.or material within their jurisdiction. RER reserves.the xight to revoke this acceptance, if it.is determined by Miami-Dade County Product Colitrol Section that,this product,-or material fails to meet the requirements of the applicable building code. This product is approved as described herein;and has been designed to comply with the Florida Building Code ,including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Titanium`UDLr25 PLUS,Titanium,UDL-30,Titanium®UDL-50 UDL TT,UD.L TF, UDL TTMC-300,RhinoRoof U10,RhinoRoof.U15,Rh►noRo.of U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments LABELING: Each unit shall bear a permanent-label withthe manufacturer's.name or logo,city, state and.following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this-NOA shall be considered.after a renewal application1as:been filed,and there has been no:change. in the applicable building:code;negatively affecting the performance of this product, TERMINATION of this N.OA will occur after the expiration date,or if there has-been a:revison or change`in:the materials,use,,and/or.manufacture.of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to.comply with any section of this NOA.shall.be cause.for termination and removal of NOA. 'ADVERTISE'MENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the .expiration.date may displayed in a'dvertis'ing literature: If any portion of the NOA is displayed,then it shall be done in,its entirety. INSPECTION A copy o.fthis entire NOA sl1alI be provided to the user by the manufacturer or its distributors;and. shall be available for inspection,at the job site at the request of the'Building Official. This NOA renews and revises NOA No. 13-0610.01 and consists of pages ]'through 5. The subtilitted docu n-entation was YeYlewed by Alex Tigera. NOA No.:14-0603.18 QMIAMMI•DADE COUNTY Expiration Date: 08/08/18 Approval Date: 06/11/15 Page.I of,5 ROOFING COMPONENT APPROVAL Cateaory: Roofing Sub-.Cateeory: Underlayment Material: Polypropylene SCOPE: This acceptance is for Titaniuiri'UDL-25:P.LU$i Titanium's UDL-30 TitaniumO UDL-50,UDL TT,UDL,TF,: UDL TTMC-300;RhinoRoof`U10,RhinoRoof'U15,RhinoRoof-U20,Titanium UDL25,and'RhinoRoof RSA Synthetic Underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies. where ASTM D226 Type undeclayment is specified and installed with prescribed approved fasteners and-fastener densities.Designed to comply with the Florida.Building Code including the High Velocity Hurricane Zone of the Florida Building,Code PRODUCT DESCRIPTION: Test Product Product Dimensions Specification Description Titanium°UDL-25 PLUS, 48"x 250' rolls ASTM D226 Woven,synthetic polymer underlayment with one 1Llai z factizring; Type I&Il: side.coated'wi.th UV protected and-slip resistant Location#1&#3 polymer stabilized polypropylene on.both sides. Titanium®UDL-30. 48"x 250' rolls ASTM D226 Woven synthetic.polymer.undedayment with two .Manufacturing Type I&1I sides coated with UV protected and slip resistant Location#1&#3 polymer stabilized polypropylene on both sides. Titanium'UDL-50 48"x 25,0' rolls ASTM D226 Wovetl synthetic;polymer underlayment with two Manufacturing Type.I&II sides coated with UV protected and slip resistant Location#1&#3. polymer stabilized polypropylene on both.sides.. UDL TT 48"z 250' rolls ASTM,D226 Woven synthetic polymer underlayment with one Manufacturing Type I&Il side coated with UV protected,and slip resistant Location.#1 polymer stabilized polypropylene on both sides. UDL TF 48"x250' rolls ASTM,D226 Woven synthetic polymer.underlayment with two ManufacturingType I&11 sides coated with UV protected.and slip resistant Location#1 polymer stabilized.polypropylene,on both sides. UDL TTMC=300 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type I&lI sides coated with UV protected and slip resistant Location.#2 polymer stabilized polypropylene on both sides. RhmoRoof U1.6, 42"x 286"rolls ASTM:D226 Woven syntbetiapo;lymer underlayinent with two Manufacturing Type I&II sides Boated with'UV protected and slip resistant Location #3 polymer stabilized polypropylene on both sides.. MIAM COUNTY- NOA No.:.14-0603.18 `PDADE CO� Expiration Date: 08/08118 Approval Dater 06/11/15 Page 2 o#,,5 I Sf RhinoRoof U15 42"x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type Iand 11 sides.coated with UV protected and.slip resistant Location #3 polymer stabilized polypropylene on both sides RhinoRoof U2U 42"x 286' rolls ASTM D226 Woven synthetic polymer undeilaytnent with two Manzrfacturing.Location.43 Type:I and II side&coated-with UV protected and slip resistant polymer stabilized,polypropylene onboth sides, itanium,UDL25 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two Ylarnfacturing cation #3 Type I and 11 sidos.coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. 'RhinoRoof RSA 36"x 67' rolls ASTM D1970 Unreinforced polymer modified bitunieia Material Manz facturinLocatiota #4 synthetic to.the underside.of a polymer-coated, synthetic woven sheet. The,undbfMde is backed WWI a;release film. MANUFACTURING LOCATIONS: 1. MLI 2. ML2 3. ML3 4. ML4 EVIDENCE SUBMITTED. TesfAgency Test 1'dentifier Test Name/Renort Date IntertekTesting,Services #3031783 TAS 104 02/19/03 3119607COQ-003B ICC-ES AC48 02/2:0/08 3124826-01 ASTM El 08 02%19/08 31.24926MID-007 ASTM El 08 02/25/08 311801000Q-003 ASTM D226 02/20/08 3130639COQ-:002A ASTM D226 02/20/08 3146738COQ-0.03A ASTM D226 06/20/11 3146738QOQ-003B• ASTM 13_1876 TAS,117 .03/28'/08 101465036COQ=001 ASTM D1970 06/27/14 100539395COQ-006 ASTM D226 06/02/14 1018G3MICOQ-001 A ASTM:D22.6 10/28/14 101823107COQ-011 ASTM D226 12/09/14 Trinity ERD 115010.05.1:0 ASTM D.4798/D226 05/1,4/10 138010.08.11 ASTM D226 08/11/11 135520.08.1'1 ASTM D2523/D1781 08/17/11 NOA No:;14-0603.18 MIAMIDADECQUNTY Expiration Date: .08/08/18 Appr6v#1 Date: 06/11%1;5 Page.3:of 5: INSTALLATION SPECIFICATIONS: Titanium`s UDL-25 PLUS, Titanium' UDL-30, Titanium' UDL-50, UDL TTMC-300, UDL TT UDL TF., RhinoRoof U10, RhinoRoof U-15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments 1. Titanium®UDL-25 PLUS,Titanium'UDL-30,Titanium®UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof U10,RhinoRoof U 15,RhinoRoof U20,Titanium UDL25,,and RhinoRoof RSA Synthetic Underlayments shall,be installedin.strict compliance with applicable Building Code. 2. Titaniumo UDL-25 PLUS,TitaniumO UDL-30,TitaniumO UDL-50 UDL TTMC-300,UDL TT,UDL TR, RhinoRoof U 10,RhinoRoof U 15,RhinoRoof U2,0,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. Titanium'UDL-25;PLUS,'Titanium'UDL-301 Titanium'UDL-50,;UDL TTMC-3':00,UDL TT UDL TF, RhinoRoof U10,.Rl inoRoof U 15,RliinoRoof U20,and Titanlum;UDL25 Sy nthedc'Underlayrnents shall be. fastened with Miami-Dade approved corrosion resistant tin-caps and 12 gauge f '/4"'annular ring-shank nails, spaced 6"o.c.at all laps and three staggered rows fastened 12"ox. in the field of the roll. 4. Titanium'UDL-25 PLUS,Titanium'UDL-30;Titanium'UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments may be. used with Asphaltic shingles,.Wood shakes and shingles,Non-structural"metal roofing, and,qua►Sy slate.T taniurno UDL-30,Titaniume UDL-50,UDLTTMC-30.0,UDL TT,UDL TF,RhinoRoof U10,RhinoRoofU15,RhinoRoofU20;Titanium UDL25 and RhinoRoofRSA Synthetic Underlaymentsshall not be:used as roof tile,underlayments: 5. For Roof Tile applications.;Titanium®UDL=25,PLUS maybe used as an anchor sheet in roof'tile,applications when used in combination with a top membrane layer,consisting of a Miami=Dade approved TAS 103 self- adhering underlayment.(See current NOA listing of approved TAS 1.03 self-adhering underlayment for installation guidelines and limitations of use), 6. For fire classification of specific roof assemblies using Titanium® UDL-25 PLUS, Titanium' UDL-3.0, Titaniumo UDL-50,UDL TTMC-300,UDL TT,UDL TF,RhinoRoof U1.0,RliinoRoof U15,RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayrnents_refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for,building permit shall be accompanied by copies of the following: 1. This Notice.of Acceptance. 2. Any :other documents required by the Building Official or -applicable. building code in morder to properly evaluate the installation of this material. NOA Not 14=0603.18 MIAMI-DADS COUNTY Expiration Date: 08108/1;8 Approval Date: 06/11/15 Page 4 of;5 DMITATIONS: 1. Fireclassification is not part of this acceptance;:refer to a current Approved Roofing MaterialsDi.rectoiy for fire ratings of this product. 2. This acceptance is:for prepared.roofing applications. Minimum deck requirements:shall be in cotiipliance,with applicable building code. 3.. T.;itanium0 UDL 25 :PLUS, Titanium0-UDL-30,,Titanium'- UDL-50;:UDL TTMC-300, UDL TT, UDL TF; RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UD.L25, and RhinoRoof RSA Synthetic Underlayments shall be applied to.a smooth,.clean and dry surface with deck-free of irregularities.All nails;n the deck shall be carefully checked for protruding Beads. Re=fasten any Goose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Titanium® UDL-25 PLUS, Titanium" UDL-30, Titaniumo UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayinents,shall not:be hot mopped,refer to manufacturer's published literature for product.coinpatibility. S. Titanium® UDL-25 PLUS, Titariuiril_UDL-3:0, Titanium® UDI-50, UDL:`TT IvIC-300, UDL TT, UDL TF; RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Und'erlayments.shall norbe:appl:ied:over an existing roof membrane.as a,recover system,. 6: Titanium® UDL-25 PLUS, Titani'UMV UDL-30,. Titanium'0 UDL-50, UDL.TTMC-3.00, UDL TT, UDL TF, RhinoRoof U10, .RhinoRoof U15 RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be left exposed as:a temporary roof for longer than 30 days of application. 7. UDL_TTMC-300 Synthetic'Underlayment shall'not'be left exposed.as a temporary roof for longer-than.180 days of application. 8. Titanium®.UDL-25 PLUS,.Titanium' UDL-30; Titaniume UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof:'-U10, RhinoRoof U1.5, RhinoRoof U20, Titanium. UDL25.,, and RhinoRoof RSA Synthetic Underlayments are,components used in roof system assemblies.-Roof system assembiies:are approved under a specific Notice.of Acceptance, Refer to Prepared Roofing.system.Product Control Notice of Acceptance,for listed approval of this product with specific prepared roofing products. 9. Titanium' UDL-25 PLUS, Titanium® UDL-30, Titanium® 'UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium; UDL25, and RhinoRoof RSA Synthetic Underlayments may be used with any approved roof covering Notice ofF.cceptance Iisting`TitaniuniO UDL-25 PLUS, Titanium' UDL-30; Titanium®UDL-50, UDL_ TTMGM 300, .UDL TT, UDL TF, RhinoRoof U1.0, RhinoRoof U-15, RhinoRoof'U20, Titanium,UDL25, and .RhinoRoof RSA Syntlietie Underlayrn6fits, as a component part of an assembly in the Notice of Acceptance. If Titanium°UDL-25 PLUS, Titaniumi°UDL- 30, Titanium' UDL-50, UDL TTMC=300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are not listed, a request may be made to the. Authority Having Jurisdiction (AHJ) or the Miami-Dade. County Product Control Department for approval provided that appropriate documentation is. provided to detail' compatibility of the products, wind uplift resistance,and fire testing.results. 10. A11,membranes of packaging.shall bear the imprint or identifiab,l'e%marking of the manufacturer's-name.or logo and, the following.statement: "Miami-Dade County Product .Control. Approved" or.the Miami=Dade County Product Control Seal as shown below. MIAMMADE COUNTY 1;1. All.products.listed herein shall have a quality.assurance audit in accordance with the Florida Building Code .and.Rule 61020-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI - NOA No '14=0603,18 Expiration Date:•.08/08/1$. Approval Date::.66/11/15 Page 5,of,.5