Loading...
HomeMy WebLinkAboutEngineering 11 I PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com October 5,2015 Re: ' Window Replacement 10201) South Ocean Dr. Jensen Beach,FL 34957 To Whom It May Concern: Our office hr calculated � thererequired design pressure in accordance with ASCE 7-10 for q a replacement of the roll up door at the above referenced address. Wind speed: V,lt: 165mph,V.d: 124 mph Exposure:. D Enclosure T Enclosed Window Size: Per Attached Schedule(same size as windows removed). Quantity of Doors: 1 Location: I Zone 4 (Per Attached Sketch) Required De ign Pressure(Zone 4): +48.8/-52.9 PSF Windows to be installed shall be equal to,or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Windows: PGT SH-200 NOA#15-0528.22 (+55.0/-63.8 PSF). Thank you four your attention to this matter. Submitted b : PAUL WELCH INV. i 0 Paul Welch,P.E Reg.No 29945 Attached: -- I Product Approval'Affid. Area of Work Plan �OF ?7 PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@uaol.com Window Replacement 10200 South Ocean Dr. Jensen Beach,FL 34957 13 Sm Area By calk XOPR XBS1=1154 •i. 12 XOPR-96 W I 4 CWRINDOW REPLACEMENT#1 WINDOW REPLACEMENT#2 (2)—36"WIDE X 38"HIGH (1)—36"WIDE X 38"HIGH S.H. WINDOW S.H. WINDOW i AREA OF WORK PLAN nts... +—NORTH i NOTE:RE-USE EXISTING ACCORDIAN SMYITERS AT WINDOW REPLACEMENT. Paul Welch,P.E. I �� Reg.No 29945 j October 5,2415 1 Planning& Development Services Department Building & Regulations Division Product Review Affidavit Building Permit# Owners NameApplicant: Product Openingf Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Design Pressure Number Tvue Windows Ns '14tt x Isle MSN.Et.^'c�EQ u�rtz.AcQ�.a 6AiiNlena MEE.'[ttaL t--A.4 L, s6ND ttQC . Fixed Glass Block Glass Skylights Sliding Glass Doors Swing Type Doors French Doors oarage Doors Hurricane Protection Root Ventilation r Mut L►o+l 1rc x0.125 WcxA F -1SAv% Mites, Zv—kegEj> -&MC>P55 +48.8/-52,9 +/_84,aJ V6T �` �4 -fi e LI.tP I have reviewed the above components or cladding and I have approved their use in this structure. These ptoducts provide adequate resistance to the wind loads and forces specified by current code provisions. Name: PAUL WELCH P.E. , Signature: W44% fifi} Design Profs PAUL WELCH P.E. . Cert.No. 29945 Date: 0 -n W