Loading...
HomeMy WebLinkAboutProduct Approval (3) flornda Building Code Online RECEIVED OCT0 81015 Page 1 of k t t it �, ti• R �' uu8 ,�, rc�.. t �ls �-� •-y'..,pr�iL` ^ BCIS Home Log In User Registration Hot To ` s �� } r Submit Surcharge Stas&Facts Publications FSC Staff SCIS Site Map Llydcs - Search Business' s Professi64 #PPodu�Approval .USER Public User pro�J->+OC•G'dh'p�{i>Cruchrct or Arnli�tion Saa-h>Aool'canon Uct>Application Detail FL# Application Type FL5823-R6 Revision Code Version 2 Application Status Approved � Comments Archived 04/16/2015 Product Manufacturer o �!Indow�5vstems Address/Phone/Emailrnr�^ 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 ekoss@cws.cc Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@Lws.cc Category WIndoa�s Subcategory Inge u_ Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer d Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE V. Validation Checklist-Hardcopy Received Certificate of Independence FL5823 R6 COI EvalReo CL�JS-155C fSH 8100 Im act' df Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-05 2005 ASTM E1300-04 2004 ASTM E1886-02 2002 ASTM E1886-05 2005 ASTM E1996-02 2002 ASTM E1996-05 2005 PA/TAS 201/202/203 1994 b"'//WWW 1 nrii-Inhi711dinc Hirtl—l,•.,- .]ai _____.n .Fionda Building Code Online Page 2 of 3 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/14/2015 Date Validated 04/2112015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summa ry of Products FL# Model,Number or Name Description -J[ 15823.q W" J&,f0D .idyl jSiq IeH pMct-'XZ— _g g_QR Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R6 11 CWS-1550(SH-8100,Impact).pdf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.Large Missile,see installation dwgs.for Max.size FL5823 R6 AF- DuPont PVB NOA 13-0129 27.p and DP.Outer lite in I.G.must be safety glazed when used FL5823 R6 AE F-vaJRW CWS-155C(SH-8100,Impact).pd above 30 ft.in HVHZ.Glass complies to ASTM E1300-04. FL5823 R6 AE Ouanex(Mikron)NOA 12-1017 02.p Created by Independent Third Party.,Yes 5823.2 SH-8100 Cont.Hd.&Sill SH-8100 Cont.Hd.&Sill(double Single Hung),Impact,74 1 1/8"x 63". Limits of Use Installation Instructions Approved for use in HVHZ*Yes FL5823 R6 11 CWS-440B(SH-8100,IMP,74x63, Approved for use outside HVHZ:Yes CONTHDSL).od Impact Resistant:Yes Verified By:Lucas A.Turner 58201 Design Pressure:N/A Created by Independent Third Party:Yes Other.Max.unit size 72-7/8"x 61-3/4".Outer lite in I.G. Evaluation Reports must be safety glazed when used above 30 ft.in HVHZ. FL5823 R6 AE QgPont PVB NOA 13-0129 27.gd Glass complies to ASTM E1300-04. FL5823 R6 AE EvalRep 0,VS-4406(SH-8100, IMP,74x63, CONTHDSL).pd FL5823 R6 AE Ouanex(Mil(ron)NOA 12-1017 02.pd Created by Independent Third Party:Yes 5823.3 SH-8100 Cont.Hd.&Sill SH-8100 Cont.Hd.&Sill(double Single Hung),Impact,74 1 118"x 72". Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL5823 R6 11 CWS-491B(SH-8100,IMP,74x72 Approved for use outside HVHZ:Yes CONTHDSL).pd Impact Resistant:Yes Verified By: Lucas A.Turner 58201 Design Pressure:+67.5/-67.5 Created by Independent Third Party:Yes other:Large M15stre,OP=+/-67.5 pSf,Max.size 74-1/8" Evaluation Reports x 72".Outer lite in I.G.must be safety glazed when used FL5823 R6 AE DuPont PVB NOA 13-0129 27.pd above 30 ft.in HVHZ.Glass complies to ASTM E1300-04. FL5823 R6 AE EvalRep CWS-491B(SH-8100,IMP,74x72 CONTHDSL).Pd FL5823 R6 AE Ouanex(Mikron)NOA 12-1017 02.gdf Created by Independent Third Party:Yes 5823.4 SH-8100 Vinyl Single Hung Oriel SH-8100 Vinyl Single Hung Oriel Window w.HD FMR,5 HI I sash. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R6 if CWS-295C(SH-8100,IMP,52x96).odf Appircived for use outside HVHZ;Yes Verified By: Lucas A.Turner 58201 Impact Resistant;Yes Created by Independent Third Party:Yes Design Pressure:+67.5/-67.5 Evaluation Reports Other:Large Missile,52"x 96"w/5 HI sash,+/-67.5 psf. FL5823 R6 AE DuPont PVB NOA 13-0129 27.pd Outer lite In I.G.must be safety glazed when used above 30 FL5823 R6 AE DuPont SGP NOA 11-0624 02.pd ft.in HVHZ.Glass complies to ASTM E1300-04. FL5823 R6 AE EvalRep CWS-2950(SH-8100,IMP, 52x96).i?df &582.3 R6.AE Quangx(Mikron)NOA 12-1017 02.2d€ Created by Independent Third Party:Yes MIAM MlAhH-DADS COUNTY • PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Maud,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DPVISION T(786)315-2590 -F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) MMMmiamidade.gnteconowy Quanex Building Products,Inc. 1034 Sixth Avenue North Kent,WA 98032 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION:The approved White Rigid PVC Exterior Extrusions for Windows and Doors are to be produced by Extruders Licensees in"AAMA Certification Programs for rigid PVC Extrusions".The extrusions shall meet ASTM D 4726,classification(ASTM D 4216) 1-10154-33-0000, 1-20131-13-0000 or 1-40131-13 and the following properties. Description Test Properties Rate of Burning ASTM D-635 Class Cl Self Ignition temperature ASTM D-1929 925°F>650 Average Smoke Density Rating ASTM D-2843 43%<75 Flame Spread Index ASTM E-84 262<75 Tensile Strength(Difference: *Exposed&Unexposed) ASTM D-638 4.98%<10 *Exposed per Section 2605.2 of The.Florida Building Code. MISSILE HWPACT RATING:None This NOA revises NGA#11-0830.09 and consists of pages I and 2,as well as evidence page E-1. The submitted documentation was reviewed by Carlos NL Utrera,P.E. NOA No: 12-1017.02 Expiration Date:December 26,2016 Approval Date:February 7,2013 Page 1 MIAMI- E MIAMI DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD-AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) wwymmiawidade.aov/economy Quanex Building Products,Inc. 1034 Sixth Avenue North Kent,WA 98032 LIMITATION:This approval does not include an evaluation of structural performance of this component. Test reports and other required documents shall be submitted to Dade County Product Control;showing that the systems using this PVC Extrusion will resist the loads according to Chapter 16 of the F.B.C.,in.order to issue a specific product approval for the system. ]LABELING:Each carton containing certified extrusions shall be labeled with the AAMA PVC Extrusion Certification Label with the extruder name,city,state and"NIDCA".In addition,(a)each Certified Extrusion shall be labeled every 4 ft or less on the underside with the Extruder Code and"MDCA7 or(b) each finished product assembly shall be labeled with a permanent label and/or stamp with the Extruder Code and"MDCA". RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product, TERNUNATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. 'toll NOA No:12-1017.02 Mt�+rn ECO Expiration Date:December 26,2016 .II '''• •�I Approval.Date:February 7,2013 Page 2 Ouanex Building Products,Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE A. DRAWINGS. 1. None. B. TESTS "Submitted under AAMA Master File#98-0036" 1. Test report on Rate of Burning,Ignition Temperature,Density of Smoke, Surface Burning Characteristics,Accelerated Weathering and Tensile Properties Test of"PVC Extrusions from 5 different manufacturer"selected by AAMA",prepared by ETC Laboratories,report#ETC 97-26440910,dated 04/21/1998,signed and sealed by J. L.Doldan,P.E. C. CALCULATION 1. None D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATION "Submitted under AAMA Master File#12-1037" 1. 2-1037- 1. Procedural Guide for the AAMA Fenestration Exterior Thermoplastic Profile Certification Program(AAMA 109-11). 2. Voluntary Specification for Rigid Polyvinyl Chloride(PVC)Exterior Profiles (AAMA 303-08). 3. Current list of AAMA Fenestration Exterior PVC Profile Certified Licensees. F. STATEMENTS "Submitted under AAMA Master File#12-103?'" L. 2-1037- L. Statement letter of code conformance to 2010 FISC issued by Turner Engineering& Consulting,Inc.,dated 04/25/2012,signed and signed by Lucas A.Turner,P.E. 2. Standards' equivalency report issued by Turner Engineering&Consulting,Inc.,dated 04/25/2012,signed and signed by Lucas A.Turner,P.E. 3. No financial interest issued by Turner Engineering&Consulting,Inc.,dated 04/25/2012,signed and signed by Lucas A.Turner,P.E. G. OTHERS 1. Letter stating that Mikron Industries,Inc.is a wholly owned subsidiary of Quanex Building Products,Inc.,dated 10/10/2012 and signed by David C. Gadd. "Submitted under NDA #06-1220.01" 2. Member acknowledgement letter issued by Mikron Industries, Inc. -Spectus Systems, on 08/03/2001 and signed by Douglas W. Allen. 3. Component Release Letter issued by American Architectural ManufAacrs Association on 09/07/2001 and signed by Dean Lewis. Car os M.Utrera,P.E. Product Control Examiner NOA No 12-1017.02 Expiration Date:December 26,2016 Approval Date:February 7,2013 E-1 TElm,V T1b 1239 Jabara Ave. U North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 CONSULTING,INC. FBPE C.O.A. #29779 Evaluation Report 155C April 18,2015 Product Description: Series 8100 PVC Single Hung,Large Missile Impact,53 1/8"x 76"unit size at up to+/-67.5 PSF,36"x 62"unit size at up to+67.5/-75 PSF,-7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite Manufacturer: Custom Window Systems,Inc. 1900 SW 44"'Ave,Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 5"' Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-155C,signed and sealed by Lucas A.Turner,P.E. 3) Test Report NCTL,21 0-3 668-1,-1 A,-2,-2A,3669-1,-1 A,-2,and-2A. by National Certified Testing Laboratories,Orlando,FL,signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201,202,203 1994,ASTM E 1886, 1996 2002/2005,and AAMA A440 2005 4) Supplemental CaIcs.to support CWS-155C, signed and sealed by Lucas A.Turner,P.E. Installation: Units must be installed according to approval document CWS-155C. Limitations of Use: This product: * May be used in O/X configuration in sizes,design pressures,and with max.glass DLO heights as shown incWS-155C * Is impact resistant and does not require the use of shutters * May be used in the High Velocity Hurricane Zone * Requires 7/8"Insulating Glass consisting of 1/8 An'nealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-118Ann) inboard lite * Requires Dupont PVB Interlayer per Miami-Dade N.O.A. 13-0129.27' * Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 12-1017.021 11 have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5th Ed.(2014)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in any other entity involved in the testing or approval process of this product. E 4,0' S 4/18/2015 Lucas A. Turner-P.E- 8 T'A T F C 0 4u FL PE#58201 4 0 R �O N ...... Lucas A. Turner 4,'414#1131610 2015-04-18 22.13-04-On $' IAM 31HAA11-DADE COUNTY o PRODUCT CONTROL SECTION 11805 SW 26 Street;Room 208 DEPARTMENT OF REGULATORY AND ECONOIWC RESOURCES(RXR) Miami,Florida 33175-2474 BOARD AND CODE ADNIINISTRATION DIVISION T(786)315-2590 F(786)115-2599 NOTICE, OF ACCEPTANCE (NM www.miamidade.eqyleconom EX DuPont De Nemours&Co.,Inc. DuPont P&]P Chestnut Ran Plaza,712/161,P.O.Box 80712 Wilmingtou,I)Ef 19880 SCOPF': This NOA is being issued under the applicable rules and regulations governing the use of construction materials, The documentation submitted has been reviewed and accepted by Miami-Dade County RRR- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this-product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. ICER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane,Zone. DESCRIPTION:DuPont Btttacite@}PVR Interlayer APPROVAL DOCUMENT:Drawing No.13-012917,titled"DuPontButacite@ PVB Interlayer",Sheet I and 2 of 2,dated 01/15/2013.,prepared by E.1.DuPont Do Nemours&Co,Inc,signed and sealed by Allan A.Kozich,P.E.,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the'Miami-Dade County Product Control Section. MISSELF,IWACT RATING:None LABELING:Laminated lites under this Product Approval shall be permanently marked in a comer of the glass with:"MI)CA-Butaciteg PVT.standing for'Mami-Dade Count),Approved—Butacite@ PVB",and the laminator's identification mark. These,marks shall he applied by the individual laminator producing the finished laminated glass product containing the ButaciteaD PVB interlayer. RE,NE WAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building*ode negatively affocting the performance of product. TF,RMMATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal ofN0A. ADVE RTISEMM NT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#11-1118.03 and consists of this page I and evidence page E-t,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos hL Utrara, NOA No.13-0129.27 Expiration Date:December 11,2016 MIAMI-DADr- —UNTY Approval Date:April 11,2013 1 Q%amm,I M., Page 1 B.I.DuPont De NLw2urs&Co..Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing,No. 13-0129.27,titled"DiPont Butacite@ PVB Interlayer", Sheet 1 and 2 of 2,dated 01/15/2013,prepared by E.1. DuPont De Nemours&Co.,Inc,signed and sealed by Allan A. Kozich,P.E. B. TESTS "Submitted under NOA #11-0624.01 Test report Standard Date Signature 1. A2280.01-10-18 ASTM D1929 03/29/11 Joseph A.Reed,P.E. 2. A2280.01-10-18 ASTM D 635 03/29111 Joseph A.Reed,P.E. 3. A2280.01-10-18 ASTM D 2843 03/29111 Joseph A.Reed,P.E. 4. A2280.01-10-18 ASTM G 155 03/29111 Joseph A.Reed,P.E. 5. A2280.01-10-18 ASTM G 158 03/29/11 Joseph A, Reed,P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Mianfi-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted undej-NOA #1.1-11.18.03" 1. Statement letter of code conformance to 2010 FBC issued by Allan A. Kozich & Associates,dated 03101/201.2,signed and sealed by Allan A.Kozich,P.E. "Submitted undei-NOA#II-0624.01" 2. Statement letter of co.de.conformance to 2007 FBC.and no financial interest issued by Allan A. Kozich Associates, dated 08/09/2011, signed and sealed by Allan A. Kozich,P.E. ' I-30�4ie 4#-6 Carlos M.Utrera,P.E. Product Control Examiner NOA No.13-0129.27 Expiration Date:December 11,2016 Approval Date:April 11,2013 E-1 1" DUPONT BUTACITEQ PVB INTERLAYER Y PROQ99T DESg&1FTIQN MANUFACTURED BY: E.I.DUPONT DE NEMOURS&CO.,INC. A PLASTIC INTERLAYERMATERiAL FOR LAMINATION wrrH GLASS ON BOTH SIDES. A TYPICAL GLAZING IS-MADE OF THE FOLLOWING COMPONENTS: A B C A - 1/8" 3.0 mraAnnealed Glass SECTION 8 - 0.03U'(0,76 mm DuPont Butacitee PVB Inteda r C-- 1/8- 3.0 mm Annealed Glass MATERIAL CHARACTERISTICS Butaclte@ PVB Interlayer.(Clear) I]eoi nation Test Properties Butacitee PVB Interfe er Megr Self Ignition Tem erature ASTM D1929 788'F 420 Flash Ignition Temp2rature ASTM D1929 788°F L42Q°C Lvq Smoke Density Rating ASTM D2843 7.2 Burning Rate ASTM 0635 0 mmlmin. Xenon Weathering(4500 hrs) ASTM 0158-02 t Weathering Flexural Strength Method A ASTM 0166-02 Method A Before After 2940 psi 3189 i *WEATHERING PER SECTION 2612 OF THE FLORIDA BUILDING CODE THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANOE OF THIS COMPONENT. SYSTEMS INCORPORATING THIS COMPONENT SMALL APPLY FOR A PRODUCT APPROV* TO THIS OFFICE AND SHALL,SUBMIT TEST REPORTS AND OTHER REQUIRED DOCUMENTS SHOWING THAT THE SYSTEM USING THIS COMPONENT WILL DESIST THE LOADS ACCORDING TO CHAPTER 16 OF THE FLORIDA BUILDING CODE. W.49190t_asaama Iriterlaver.:., . - r.- �,t_r� E I:-duPbnt de Nemours-&Co. Inc. *ic,���II�>itrr�taie� { ' x ;Dil ? i}t `K f�'�°� Chestnut Rust Plaza Bldg 712/161 : , �*yt�EM ... �' - Pru tttt3orrgb3 P.0. Box 84712 4 1? No q�88� Z i Wilrnington DE 19880-0712 Phone: 302-999-2125 « - Fav,File.*U-012°I.M Sheet 1O#2 I'm Sun OF �d dV�: DrawIng Gate: 01115M3 ,� ,� .4� r Allan A. Kozich, PE , �•#Dose# 4w• Na. 176 Re isirati0n#'19964 �jsj1NA� Ile#aj DUPONT BUTACITEO PVB INTERLAYER Material Characteristics Butacite@ PVB Interlayer(Colors) . Designation Test Properties Salt IgnMon Temperature 1t ASTM 01929 788'F(420'C) Self Ignition Temperature L21 .ASTM D1929 788'F(420�C Sett Ignition Temperature[3] ASTM D1929 Self Ignifion Temperature[4} ASTM D1929 788'F{420`C} Self! rrihon Temperature Lq ASTM D1929 788`F(420"C) Flash I nation Temperature 11 ASTM A1929 788 t(4201C Flash Ignition Temperature 12 ASTM €31929 770`F 410!C} I leph Ignition Temperature[31 1 ASTM D1929 770`F{410 t} Flash Ignition Temperature[4] 1 ASTM D1929 788`F(420`Q Flash Ignition Temperature ASTM D1929 788'F 420'C Avg Smoke Dens •Rating[11 ASTM D2843 7.2 . Av Smoke Densl Ra[ing[ ASTM D2843 9.1 Avg Smoke bensil Rating[3 ASTM D2843 10.2 -Avg Smoke Density Ratan [4j ASTM D2843 10.1 Avg Sfnoke Density Rating[ ASTM D2843 8.1 Suming Rate 11ASTM D836 0 mmlmin. Bund Rate[21 ASTM D635 4 mmlmin. Burnt Rate[3 ASTM D636 0 mm/min. Buming Rate{4j ASTM 0635 0 mm/min. Burning Rate[5[ ASTM D635 0 mmtrntn. [t] Clear Butacite@ PVH intedayer Daae vrl�@r�Miveids 121 Charcoal Grey ButaciteS PVB Interlayer [31 Stue-Green Sutacite@ PVB Interlayer 141 Azure Blue Butadte®PV8 Interlayer [51 Solar Bronze Butacite@ PVB interlayer 0d 1p� THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANCE of THIS COMPONENT. SYSTEMS.INCORPORATING THIS COMPONENT SHALL APPLY FOR A PRODUCT APPROVAL TO THIS OFFICE AND SHALL SUSMIT TEST REPORTS AND OTHER ARQUIM0 OOCUME14TS SHOWING THAT THE SYSTEM USING THIS COMPONENT WILL RESIST THE LOADS ACCORDING TO CHAPTER'I6 OF THt FLORIDA eUIMINS CODE. I3uRorltBu6bitoO PVB Intarlavee ����at!A� 'teUs�`. _, E.I.duftnt de NernouTs&-Co., Inc. �o*,�� , �••..,.. 1 �� DuPont KIP GLS ,,tiG� � `�• '� Chestnut Run Plaza Bldg 7121161 tic P. 0. Box$07'12 Wilmington DE 19880-0712 • g Phone; 302-999-2125 kV• fa[e#13-012U?Sheet 2of 2 ®R'a Drawin Bate: 01115/113 ` '�%:, . � ►ai 04-104t'513 Allan A. Kozich, PE Ra lstration#16864 SINGLE HUNG - LARGE MISSILE IMPAC T 99UMLIMU& (SHOWN w/DIFFERENT OPTIONS) 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINS 3Y3S TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND I SOD SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CwS.Cc 2.GLAZING OPTIONS:(SEE SHEET 2) OVERALL FLANGE WIDTH 3.CONFIGURATIONS:°01X'. 8100 PVC 53 Ila"MAX.UNIT WIDTH___ OVERALL FLANGE WIDTH SINGLE HUMG 015dw. 4.DESIGN PRESSURE RATING: IMPACT GLASS OLD -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND .36' GLASS TABLES ASTM E-1300-04. MAX UNIT WIDTH -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER INFILTRATION TEST PRESSURE AND GLASS TABLES i;4 1, LU 3-1-10"jjr ASTM E-1 300-04. 771/4' GLASS DLO MAX 5, OVERAL A ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED FLANGE IN THE 0 ESIGN OF THIS PRODUCT,SEE SHEET 6 FOR ANCHOR HEIGHT DETAILS.WINDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 0 GLASS 63114' 1 0 z r DLO OVERALL Lil 0 761, FLANGE 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT ROTARY MAX. I 1 HEIGHT o LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL 0 Z5 UNIT If g > HEIGHT 62" B B GLASS OPERATION BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO 5 R LU MAX OLD HURRICANE WINDS AND FLYING DEBRIS, w w 0 0 UNIT 7.ALL FRAMES AND VENTS FUILLYWELDED,SMALL JOINT SEAM SEALANT UHEIGHT USED AT FIXED MEETING RAIL AND JAMB. _J ul 6 37 vic 6 8.SERIES I MODEL DESIGNATION SH-8100. Y3 4 MAX. c 14: SASH ( y ( 6 GLASS 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: VDo IT HEIG� D DLO MASASX X-OPERABLE SASH,0-FIXED SASH 6 H x ar HEIGHTI CLASS ID.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR ....... LOCATION. . . .. w- DLO 0. 11.EXTERNAL WEEP SLOT=114°x 1-#14"LOCATED 4"FROM BOTH ENDS. No SB201 12.SWEEP LOCKS INSTALLED ON WINDOWS OVER 36'x 62". -ot A A C v"o'. STATE OF 0 LO o 0 R GLASS OLD GLASS 0 111;, ...... 3157161 Lucas A.Tumer 00"� IONAL _40_lLVt(r '401" MAKSASHWIOTH MAX SASH WIDTH 2015-04-09 12:43-04:00 LUCAS A.TURNER,P.E. FL PE 4 58201 1239 JABARA AVE. NORTH FORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: LOCATION MAX. UNIT SIZE DESIGN PRESSURE IMPACT RATING GENERAL NOTES AND TABLE OF CONTENTS RATING ELEVATIONS NON-HVHZ +/-65 PSF DRAWNBY: DATE: GENERAL NOTES&ELEVATIONS 1 53-1/8"x 76" ADE MIME GLAZING DETAILS...............................2 HVHZ +/-67"5 PSF DWG 4: -ge-W. SECTION VIEWS&ALT,FRAME........3 LARGE MISSILE IMPACT EXTRUSIONS&B.O.M.........................4 NON-HVHZ +65/-75 PSF CWS-155 C ANCHOR SCHEDULE&NOTES...,,.....5 36"x 62" SCA V_ SHEET INSTALLATION DETAILS.....................6 L HVHZ +67.5/-75 PSF ' 1 OF6 15'MAXD.C.(rYP.)--- (TYP-) 4*MAX.(TYP.) 8"AMAXOG O.C.(TYP.) 1900 SW 44TH AVE. 4-MAX,(TYP.)-, OCALA,FLORIDA 34474 6.MAX.(EYP.} T— V,MAX. 1 WWW,CWS-CC ANCHORATMIDSP (TYP.)-- G-MAX.(TYP.)----- r MAX.(TYP.)- 0'MAX.(TYP.)- 8100 PVC J_ SINGLE HUNG MAX.O.C. IMPACT 14" (TYP.) MAX.O.G. 1013+16` 0 MAX.O.C. MAX.O.C. (TYP.) W �MIG AAIL I 1 (TYP-) 4-(TYP) w e(TYP.) 4"(TYP.) co 0 S Z x LD Eo 1 0 cl CA > � N � LU cc a: w ff ul w Lu M a. IL P ANCHOR LAYOUT,-(FLANGE) ANCHOR LAYdUT-WIN) ANCHOR L JT-(FLANGE) ANCHOR AYOL YOUT-(FIN) < SIZES OVER 36'9 62' SIZES OVER 36"x 62* SIZES 36*x Gr AND UNDER M62l'ANDUNDER < %0 10PEW #, No 58201 P NOTES: 7:'P STATE OF 1,INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS.MAX,ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1116'18 PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE.SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P,E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. S.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6,ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO, FOR CONCRETEIGMU OPENINGS.EMBEDMENT SHALL BE BEYOND WOOD SUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT Do NOT REQUIRE 1X W ODD BUCKS BETW EEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF IX BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7,A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:S"FOR MASONRY,1'FOR WOOD AND METAL DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. ADE 06/10/08 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET S. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED, -ffwa—#I -AE7.—i 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-155 c SCALE. FMAIAAMA IDO(FIN WINDOWS),FMA/AAMA200(FLANGE WINDOWS), FMAAlVDMA 250(BOX WINDOWS),FMAIAAMAAVDMA 300(EXTERIOR DOORS) SHEET 1:25 50F6 MIN,EMBEDMENT TYPICAL HEAD ANCHORAGE SEE TABLE i — SUBSTRATE { � MIN.EDGE DIST. 114"MAX SHIM BY OTHERS SEE TABLE I MlIsL EDGE 0167. SUBSTRATE I SEE TABLE I SEE TABLE I BY OTHERS 1900 SW 44TH AVE. SEE BY OTHERS 1/4"MAX.SHIM TABLE1 OCALA,FLORIDA 34474 SUBSTRATE. WWW.CWS.CC SEE TABLE I MIN.EMBEDMENT MIN.EDGE DIST, PERIMETER SEALANT---- SEE TABLE I SEETABLE1 BY INSTALLER INSTALLATION ANCHOR l 8100 pvc INSIDE AND OUT SEE TABLE I SIN.GLEHUNG SEALANT BEHIND DMENT FLANGE BY INSTALLER L iw MAX,SHIM SEE TABLE I NPACT MIN,E PERIMETER SEALANT PERIMETER SEALANT BY INSTALLER ;oz: i2z:l By INSTALLER INSIDE AND OUT c� ,- �o IN AND OUT INSTALLATION ANCHOR LL wi w 0 > INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE I LLI SEE TABLE I FLANGE BY INSTALLER SEALANT BEHIND FIN BY INSTALLER g (n 2' HORIZONTAL SECTION HORIZONTAL C.) 0 Z _7- ------ LL TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE (j) HEAD AND SILL SIMILAR FOR FIN INSTALLATION ccrcCc LU Lu uj w cc 114'MAX SHIM SEALANT BEHIND FLANGE BY INSTALLER a PERIMETER SEALANT MIN.EMS I EDMIENT INSIDE BYINSTAND OUT ALLER SEE TABLE 1 0*16111001% SUBSTRATE BY OTHERS No 58201 SEE TABLE I EDGE DIST. -A SEE TABLE I VERTICAL SECTION4c STATE P A 6� TYPICAL SILL ANCHORAGE P�.......... "'4 IONA 100 %11 TABLE 1,APPROVED INSTALLATION FASTENERS 41912015 FRAMETVPE SUBSTRATIETYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. LUCAS A.TURNER,P.E. FLANGE CONICRETE(40 KSI MIN.) 3116"ITIN TAPCON I-liff" FL PE#58201 PERIMETER SEALANT-----,--"" HOLLOW OR GROUT-FILLED CMU(117 PCF MEN.) 3116,,rrw TAPcom 2' BY INSTALLER 1239 JABARA AVE. FLANGE FLANGE CONICRETE(2.85 KSI MIN,) 3116"ELCO ULTRACON 11. INSIDE AND OUT NORTH PORT,FL 34288 FLANGE GFOUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 2-112" HORIZONTAL SEC TION PH.941-380-1574 B0X FRAME INSTALLATION SHEET DE8t;AIPTjD9._- FLANGE 2X MIN.SOUTHERN PINE(G-0.55) 31-16-ITW TAPCON 1-3/8. 70' HEAD AND SILL SIMJLARFOR BOX INSTALLATION - - I OR ELCO ULTRACON INSTALLATION DETAILS FLANGE 2)<MIN.SOUTHERN PINE(G.0.55) #10 WOOD SCREW 1-3/8" 7)8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, _6__ FLANGE 16 GAUGE(0.060-)MIN.STEEL STUD #10-iGHILTIKWIK�FLEXORF7 FULLTHREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: 0 E� (33 KSI YIELD MIN TEKS SELF-DRILLING SCREW THRU 0,050, 7/16" ADE 06/10108 FLANGE VW ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF TAPPING FULL THREAD MIN,1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED WE,0: REV.: 1/8'STEEL(33 KSI MIN.) DRILLING SCREW 7/16' INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. THRUO.125" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS ASCWS-155 c; FIN 2X M IN.SOUTHERN PINE(G-0.55) tt8 WOOD SCREW SHOWN FOR FLANGE WINDOWS. _suTc'_ SHEET 12 GOF6