HomeMy WebLinkAboutDrawing ---------------------
-------------
32" X 80"
STORAGE
REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 732 80 17.78 5 36.8 1 -48.6 FL13540.1 55.0 1 -55.0 LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 10 FT 3 IN
ASCHETTINO RESIDENCE
134 N.E. ESTIA LANE DOOR REPLACEMENT PLAN
PORT ST. LUCIE, FLORIDA