Loading...
HomeMy WebLinkAboutEnigneering PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 October 13 2015 Email pwelchinc@aol.com ILE O Re: Door Replacement 3206 S Lakeview Cir. 1101 Fort Pierce,FL To Whom It May Concern: Our office has calculated the required design pressure in accordance with ASCE 7-10 for a replacement of the doors at the above referenced address. Wind speed: V,At: 165mph,Vim: 124 mph Exposure: D Enclosure Type: Enclosed Door Size: 8' X 6'-8" Sliding Glass Door Quantity of Doors: 5 Location: Zone 5 (Per Attached Sketch) Required Design Pressure(Zone 5): +48.5/-64.8 PSF Worst Case Doors to be installed shall be equal to,or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Door: PGT SGD-2500 NOA#15-0609.10 (+65.0/-65.0 PSF). Thank you for your attention to this matter. Submitted by: PAUL WELCH INC.. Paul Welch,P.E. i Reg. No 29945 Attached: Product Approval Affid. Area of Work Plan