NEW ROOF RE-ROOF �7 RECOVERINGKEPA|RAREA ���/ �~v
BUILT UP ROOF PLAN
ASCE 7-10&FBC 2014 5th Edition ENCLOSED BLDG A SEMI ENCLOSED BLDG OPEN
PART 2 LOW RISE C&C SIMPLIFIED
JEXPOSU REfjX L,,OjKzt 1.0 12 PITCH/MEAN PARAPET ht
MAX DESIGN PRESSURE PER NOA —qVD,0
BASESHEET 5^V NO.OF PLIES
0NG
FASTENER SPACING FOR ANCHOR/BASE SHEET A7TAcHKxcNT:
Field--"oc@Lap,# "ocPehmetec —"nc@Lap,#Rows @_ "uccomer: _"oc@ Lap,# ~~ ^oc
INSULATION BASE LAYER TYPE -- SIZE--
TYPE OFFASTENERS/OR BONDING MATERIAL
INSULATION TOP TDPLAYER TYPE -~ SIZE -^
TYPE OF FASTENERS/011 BONDING MATERIAL
NUMBER OF FASTENERS PER INSULATION BOARD: Field_�cPehmeter- Corner��___
PLY SHEET ~~ NO.OFPLIES ~- TYPE OFFASTENERS/BONDING
-~
TOP PLY NO.OFPLIES TYPEOFFA5TtNERS/BOND|0 �LvWr AW,1,02/ /��
T reasure Harvey E. Koehnen
C oast Professional Engineer#32831
B uilding Architect#AR0009471
E ngineers, Certified General Contractor #CGCO24776
Inc.
These Tables Are For Roof Coverings
Roof coverings Installed on Buildings with a
Mean Roof Height of 30'or Less Located In Exposures B, C or D
'Table R301.2[2]nF,. Pri 6 C. S-f Q5c� 7-id
COMPONENTS AND CLADDING WOt ST CASE DESIGN PRESSURE TPSF].
60 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D
(One story . (Two story*) (One story') (Two storyl
iRoof>0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9
7degrees= 11/2/12 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1
- -Zone 3 -69.811 -84.5 -97.7 -102.7 -115.9
goof>7 to 27 degrees 'Zone 1 -25.3 -30,7 -35.5 -37.2 -42
27 degrees =6/12 pitch Zone 2 -44.1 -63.4 -61.8 -64.9 -73.3
Zone 3 -65.1 -78.8 -91.2 -95.7 - 108*.1
Roof>27 to 45 degrees Zone 1 -27.8 -33.7 -40.0 -40.1 -46.2
45 degrees= 12/12 pitch Zone 2 -32.4 -39.3 -45.4 -47.7 -53.8
Zone 3 ' -32.4 -39.3 -45.4 -47,7 -53.8
.150 Exp B 150 Exp C 150 Exp C 150 Exp D 150 Exp D
(one story*) (two story) (one story=) (two story•)
Roof>0 to 7 degrees Zone 1 -24.3 -29.5 -34.1 -35.8 -40.4
7degrees= 11/2/12 pitch Zone 2 -40.8 -49A -57.2 -60.0 -67.8
Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0
Roof>7 to 27 degrees Zone 1 -22.2 -26.9 -31.1 -32.7 -36.9
27 degrees=6/12 pitch Zone 2 =38.7 -46.9 -54.2 -56.9 -64.3
Zone 3 , -57,3 -69.4 -80.3 -84.3 -95.2
Roof>27 to 45 degrees Zone 1 -24.3 29.5 -34.1 -35.8 -40.4
45 degrees= 12/12 pitch Zone 2 -28.4 -34.4 -39.8 -41.8 -47.2
Zone 3 -28.4 -34.4 39.8 -41.8 -47.2
One story'=one story building with a maximum mean roof height of 15 feet
IWO story"=two story building with a maximum mean roof height of 30 feet
-If-allowed by the Miami Dade N.O.A or Florida Product Approval., any system-that does.-not meet the
minimum components and cladding pressures for the area that the building is located per this form
may require a Florida licensed engineer to revise the fastener spacing
T C B E,Inc. 7205 Elyse Circle PHONE (772)466-5509