Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# ZRU547R16
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS liSA1
Address/Phone/Email 150 Lyon Drive
Fernley,NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polygiass.com 1 '
Quality Assurance Representative James Akins n - l
Address/Phone/Email 555 Oakridge Road V, ,
Humboldt Industrial Pkwy
Hazleton, PA 18201 !
(800) 894-4563 7-
jakins@polyglass.com ��—
jakins@polyglass.com
Category ��
Roofing
.:=-`,`d --_' -r
Subcategory Modified Bitumen Roof System LL;
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
r Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/27/2016
Validated By John W. Knezevich, PE
a Validation Checklist-Hardcopy Received
Certificate of Independence F1-1 54 R16 COI 2015 01 COI Nieminen Qdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6162 2000
ASTM D6163 2000
ASTM D6164 2005
ASTM D6222 2008
ASTM D6509 2009
FM 4470 1992
iJ/www.floridabuiidirg.org(prlpr appdd.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhc/p2bvcOeTp/o2f8%2fVkiAl.iA»�r nr,o,001��
10/8/2015 Florida Building Code Online
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/17/2015
Date Validated 06/23/2015
Date Pending FBC Approval 06/28/2015
Date Approved 08/18/2015
Summary of Products
FL# Model,Number or Name Description
16 4545 P_4lygIass-SBSL and-APPModifed SBS and APP modified bitumen roof systems
Bitumen Roof'Systems-7
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL1654 R16 II 2015 06 FINAL Al ER POLYGLASS MODBIT FL1654-
Approved for use outside HVHZ:Yes R16.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete FL1654 R16 AE 2015 06 FINAL ER POLYGLASS MODBIT FL1654-
deck. Refer to the ER Appendix for other systems and R16.pdf
deck types. 2.) Refer to ER, Section 5 for other Umits Created by Independent Third Party:Yes
of Use.
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
10-0011® 9 M
sccuritvurrmcN
httpsJ/www.floridabuilcing.org/pr/pr_app fl.aspx?param=wGEVXQwtDgvgqu2wg/g2bnFgUPv2pw6pKxAhg/`2bvcOeTg/g2f8p/`2fVk!AlJAttcpOQ°/`3d`/`3d 212
TTRINITYIERD"
F:
APPENDIX. rACHMENP F-ir".kE'S"I'STANCE..�t�`
rT�Ri�6�igME��6k,%#[N"D"70 IL"
Table Deck Application Type Description Page
1A-1 Wood New or Reroof(Tear-off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4
IA-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
ID Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
1E-1 Wood New or Reroof(Tear-Off) E Non-insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 7-8
IE-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8_9
Wood w o - of(Lear-Off)—F N—on-l—ns—uTated,—Bonded Roof Cover
2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 10
2B Steel or Conc. New,Reroof(Tear-off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12
2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20
3B Concrete New or Reroof(Tear-off) F Non-Insulated,Bonded Roof Cover 21
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28
5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29
5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30
5D CWF New,Reroof(Tear-off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30
5E CWF New,Reroof(Tear-off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-32
6B Gypsum New,Reroof(Tear-off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33
6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached insulation,Bonded Roof Cover 33
6D Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 33
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36
7B Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
>Wood: Minimum 0.75-Inch penetration.
>Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
>Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, Insulation may be any one layer or combination of polylsocya nu rate, polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral-wool roof board that meets the QA
requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
Exterior Research and Design,LLC.d/b/a Trinity[ERD Evaluation Report 139290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36
TR1NrrYj ERD
14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
_94
ABLE: PoLmAss ROOF COVERS
Reference Layer Material Application
BP-AA Base Polyglass G2 Base,FBC Approved ASTM D4601,Type II HA at 20-40 lbs/square
(Base and Ply sheets,Asphalt-Applied) Ply Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI
SBS-AA Base or Ply Elastobase,Elastobase Poly,Elastoflex V,Elastoflex S6,Polyglass HT Base 650
(SBS,Asphalt-Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS (sand-backed), HA at 20-40 lbs/square
I Polyfresko G SB5 FR(sand-backed)
SBS-TA Base or Ply Elastoflex V,Elastoflex S6
(SBS,Torch-Applied) Cap Elastoflex V,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(poly- Torch-Applied
film backed),Polyfresko G SBS FR(poly-film backed)
SA Base Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR fS—elf:Ad her!ngj
JS_BSS_
eTf:Wd_he_r_,ngjY
p Elastoflex SA P,Elastoflex SA P FR,Polyreflect
APP-TAQaSLnor'PIV Polyglass APP Base,Polyflex,Polybond Torch-Applied
(APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR
APP-SA
(APP,Self-Adhering) Cap I Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool Self-Adhering
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
> PG200 Non Fibered Roof Coating;
> PG300 Fibered Roof Coating;
> PG600 Non-Fibered Aluminum Roof Coating;
> PG650 Fibered Aluminum Roof Coating;
);, PG700 High Quality Elastomeric Roof Coating;
> PG800 Asphalt Emulsion Roof Coating;
> Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
> Polyplus 65 Premium Fibered Aluminum Roof Coating;
> Polybrite 70 Premium Grade Elastomeric Roof Coating;
> Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
16. The following represent priming requirements for gypsum-based coverboards:
> Dens Deck and Dens Deck Prime shall be field-primed with PGIOO prior to self-adhering or torch-applied membrane application. No priming is required for hot-asphalt membrane applications.
> SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
17. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-RI4 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 36
'\,/\
TRINITY I ERD
TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
No. Note 1) MDP(psf)
Base Fasten Attach Ply Cap
W-43
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c,at 4-inch lap and 6-inch o.c.in
Inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round three,equally spaced,staggered center rows (Optional)APP-TA APP-TA -90.0
Metal Plates or OMG Flat Bottom Metal Plates
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy AA
SBS
AA
SBS
AA
c
c. . ,SBS-AA, - ,SBS-TA
6-inch o. at 4-inch lap and 6-inch o. in (Optional)8P-
W 44 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-Inch long)with OMG 3"Round -90.0
P y Metal Plates or OMG Flat Bottom Metal Plates three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
W-45 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in
(Optional)BP-AA or SBS-AA SBS-AA 90.0
inch plywood long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows
W-46
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-Inch o.c.in five,
inch plywood Polyglass APP Base Duty(min.1-5/8-Inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-Inch o.c.at 4-inch lap and 6-Inch oin five (Optional)BP-AA,SBS-AA, SBS-AA,585-TA
W-47 inch plywood . . .c. , pona - , - ,Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round -120.0
P Metal Plates or OMG Flat Bottom Metal Plates equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
FW-48 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c,in five,
inch plywood long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows (Optional)BP-AA or SBS-AA SBS-AA 120.0
TABLE 1F:WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck(See Roof Cover
No. Note 1) Primer MDP(psf)
Joint Treatment Base Ply Cap
1Min._15T/3
W-9 iCch.pl� ((Opti. 62ne S85.$A (Optional).SBSrSA,_SBS-' 5135-SA,APP-SA,SBS-� 90 0
TA,.AP`JA TA A'PP-TA
W-50 Min.15/32-
inch plywood (Optional)PG100 None Polyflex SA Base (Optional)One or more APP TA 90.0
APP-TA
W-51 Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
inch plywood (Optional)PG100
place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA 97'5
W-52 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
-135.0
Inch plywood place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA
W-53 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled Into (Optional)One or more
inch plywood ) Polyflex SA Base place to create continuous bond. APP-TA APP-TA 135.0
Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 36