Loading...
HomeMy WebLinkAboutProduct Approval MIAMI-DADE COUNTY MIAMI-PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aw/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline Natural Shadow®,and Timberline American Harvest® Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Collao,R.A. NOA No.: 14-1022.20 MIAMI-DAD;COuNTY Expiration Date: 02/21/17 Approval Date:02/05/15 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®,Timberline Natural Shadow®,and Timberline American Harvest® Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 1/4"x 39 3/$" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow roof shingle,with a laminate profile Manufacturing Locations#1,2,3,4,5,6,7 GAF Timberline American 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOA No.: 14-1022.20 MIAMI-DAD;COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. ASTM D3462 11 CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 10CA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-1022.20 MiaMi•�aos l;-c3 it Expiration Date:02/21/17 Approval Date:02/05/15 Page 3 of 6 a v INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 MAMMA COUNTY Expiration Date:02/21/17 Approval Date: 02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17" OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1st NOA No.: 14-1022.20 QM1 •DAD1.11 did ,COUNTY-4 PIM Expiration Date:02/21/17 Approval Date:02/05/15 Page 5 of 6 'r DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 (1 m) 14-1/211-17-1/2 14-1/211-17-1/2" (368-445mm) (368-445mm) all guide line /A� 6-1/2"-9-1/2" B-1/2' -9-1/2' 13-��'T11 (+85•z41mm) pe5.241mm) 5-3/4"-8-1/4" (337 ) .� �. �. (148mm•159mm) to°-2-tn° from bottom of shingle � •ea 7 elf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* 'required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 MLAWDADt=_COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 6 of 6 MIAMI-W - MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street.Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) P// �,�Y,ti:x»l:i,»Idndc.eo�/economy GAF 1361 Alps Road. Wayne,NJ 07470 SCOPE: This NOA is being-issued under the applicable.rtiles,and regulations governing the use of construction materials.The documentation submitted has been reviewed:and accepted by Miami-Dade County-RER-Product Control Section to be _ used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas.other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to.perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product ControlSection that this product or material fails to meet the requirements of the applicable building code.. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal-A-Ridge@ and GAF TimbertexO Ridge Cap,Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and fallowing statement: "Miami-Dade County Product Control Approved',',unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting.the performance of this product. TERMINATION of this NOA will occur•after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, ________._for_sales,_advertisirig or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and reinoval-of NOA. - ADVERTISEIbIENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA.is displayed,then it shall be done. in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job_site at-the request of the Buildiiig,Officiai. This revises NOA# 12-01011.14 and consists of pages 1 through.9. The submitted documentation was reviewed by Alex Tigera. NIAM!•DADECONU NOA No.: 134306.08 Expiration Date: 10/17/17 A00roval Date: 08/15/13 Page i of 9 i ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles. Materials 3-Tab Perforated 'Deck Type: Wood SCOPE This approves GAF Seal-A-Ridge@ and GAF Timbertex@ Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION - Product Dimensions Test Product Description Specifications GAF Seal-A-Ridge®Ridge Cap 12"x k" TAS 110 Rip and Ridge asphalt shingle with two Shingle perforations 12 inches o.c.along the 36"length Manufacturing Location#1,'3 of shingle. GAF Timbertex@ Ridge Cap 1.2"x,12" TAS i 10 A 12"x 36"prefabricated hip and ridge Shingle fiberglass reinforced asphalt shingle with Manufacturing Location#2 perforations at 12"sections. PRODUCTS-MANUFACTURED BY OTHERS r Product Product -Size Manufacturer Description ; PL Polyurethane.Roof&Flashing Sealant various Henkel PL Sealant NP-ITM Sealant various Sonnebom a MANUFACTURING LOCATION L Tuscaloosa,AL. -- -2^_IVIt.-Vernon;lN: 3. Mobile,AL. MlAMEDADE COUNTY "-NOA No.: 13-0306.08. . �� Expiration Date: 10/17/17 Approval Date: 08/15/13 i Page,2 of 9 EVIDENCE SUBI4IITTED Test:Asencv Test Identifier Test Name/Reuort Date PRI Asphalt Technologies, Inc. TAS 100 ELK-078-02-01 06/21/02 _- TAS 100 GAF-125-02-0.1 04/04/06 Underwriters Laboratories, Inc. ASTM D3462 1 ICA45079 63/21/12 ASTM D3462 06CA18074 06116166 ASTM D3462 12CA30878 02/01/13 TAS 107 t 1CA45079 03/21/12 TAS.107 06,CA18074 06/16/06 TAS 107 12CA38,083 02/26/13 PRIConstructian Materials Technologies LLC TAS '10.0 GAF-380-02-01 11/06/12 TAS 100 GAF-367.02-01 07/12/12 LIMITATIONS 1. Fire classificati`on,is not part of this,acceptance; refer to a.current Approved Roofing ivlaterials Directory for fire ratings of this product. 2. GAF Seal-A-Ridge@ and GAF Timbertex® Ridge Cap Shingles shall be limited for use as hip and ridge cap shingles only., 3. Shall not be installed'on roof mean heights in excess of 33 ft. ' 4. All products listed herein shall have a quality,assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code, INSTALLATION 1. GAF Seal A-Ridgeg and GAF Timbertex©Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal-A-Ridge® Ridge Cap Shingles shall be in compliance with Detail `A' attached. Exposure and course layout for GAF Seal-A-RidgeO Ridge Cap Shingles shall be,in compliance with Detail A, 5. Henkel PL Polyurethane Roof&Sealant or Sonneborn'NP-1TM GunGrade must be used in the application of GAF Seal-A-Ridge® Ridge.Cap Shingles as specified in Detail A and GAF Timbertexg Ridge Cap Shingles _as specified in Detail B. 6'. Nailing:for GAF Timbettexg-Ridge-Cap Shingles siaall-be-in compliance_with.Detail '13' attached. Exposure and course layout for GAF Timbertex@ Ridge Cap Shingles slaall.be in compliance with Detail `B'. rtiaa��•naQ courarx NOA Noss I3-0306.08 .• r Expiration Date: 10/17/17. Approval Date: 08/15/13 Page'3 of 9 i LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as.seen below,or the wording"Miami-Dade County. Product Control Approved". MIAMI•DADE COUMIY BUILDING PERMIT REQUIREMENTS 1. Application for building permit.shall be accompanied by copies of the following: _1.1 This Notice_ of Acceptance. 1.2 Any other docunients required by the Building Official,or the applicable code in order to properly evaluate the installation of this system. t MlAMNOADB CdUN7Y NOA No..:.13-6306.08 ISI ''"• •IIS Expiration Date: 10117117 Approval Date: 08/15/13 Page4 of 9 DETAIL A GAF Seat-A-Ridge'Ridge Cap Shingles Application Instructions: (1)Step One—Separate<eacli piece.of GAF Seal-A-Ridgea Rid ge'Cap Shingles into three individual ridge cap;shingle pieces at perforations:(see:Figure 1). - Figure 1 /1'(12 MM) i r 42 . Mr 10111) � r Exposure- (169 MM) i �� (�(1J,ITInII� P8r!4rated :(914 nw) i I (2)Step Two—Begin laying fill ridge cap shingle with a 6-2/3"exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the.prevailing wind(see Figure 2). Figure 2 w� �2 J0 t i �'t43 Fastener 1 � � •ly4a MiaWwaneNt3A No:: 13-0306:08 II{ ""• Expiration Date: 10/17/17 Approval Date:. 08/15/13 Page 5 of 9 (3)Step Three–Apply ridge cap using 2 nails per piece 6-5/8"to 7-5/8"back from the exposed-end-and I"to 2"up from the edge(see Figure 2-for location of nails).Use only zinc coated steel or aluminum, 10- 12 gauge;barbed,deformed or smooth shank roofing nails with.heads 3/8"(9.5min)to 7/16"(12mm)in diameter. Nails should.belong enough to penetrate at least 3/4"(19mm)into wood decks or just through plywood decks.. Nails.must be driven flush with the surface of the-shingle. Over driving will damage the, _ shingle. Raised nails will interfere with"the wind resistance of the shingles. Special Application Section: For Cold Weather Application • hi cold weather,warm GAF Seal-A-Ridge'®Ridge Cap.Shingles before bending. • When self-sealing is delayed due to cold weather,apply quarter-sized dabs of asphalt plastic cement-(must conform to ASTM D4586 Type I or Type II)-between ridge cap pieces and press firmly.to insure good_.contact between pieces. • Note: Excessive application of tab adhesive can cause blistering of ridge cap,shingle. For High-Wind Zones • In high wind areas or for maximum wind resistance,apply a two quarter-sized dabs of Henkel Pl.'s'Urethane Sealant to each ridge cap shingleapproximatly 9"back from the exposed end and I"from the shingle edge.(see Figure 3). Figure.3 11.5' .Sealant 1—x(292 mm) 1" Sellante {25 mm) �R25 � ' Enduit d`etanch6it8. i Nail clavo 12n Clouer R05 Mh) 9` (229 mm) �—'(305 mm),�- - __ ----.. -----__—__------ For maximum wind speed coverage under ltd.warranty;appiy addiflonal sealant as shonm.See Special Application Section for specific detats. Para of alcance m6kinio de velocidad de.viento balo limitado i garant(a,aplica sellador adiclonal como mostrado.Vea 8ecci6n Especial de Apilcacl6n para detailes especiftc+os. Pour la couverture maximum de vitesse de vent sous limit&la garentle, ,appliquer de 1'endult d'dlanch&6 supplementaire comma inctique. Voir la section speolale d'application;pour les details specifiques. � NOA No.: 13-0306.08 sKu�EnanEcourvTr I 1.12 2 Mill Expiration Date: (0/17/17 Approval Date: 08/15/13 Page 6 of 9 I r DETAIL B GAF Timbertexo Ridge Cap Shingles Application Instructions: (1)Step One--Separate each piece of GAF Tirnberte,,&'Ridge Cap Shingles into three individual ridge cap shi igle.pieces at perforations(see Figure lj. Figure 1. i {305nim) I305mm) (305r5urrj. Self-Seal �o A Adhesive (102mmj 1 oh-Back' t 1 - 8�(2o3mmj. 1 1 SeaeAla- lne Parte PpsteriorPerforations 1 Perforadones1 Adhdsif Auto- Perforations i 'dY SeellantA 1:Endas Self-Seg)Adhesive oh Sa&. Bottom Sacker . Adhesivo Auto-Ssllante err la Parte Posterior, Apoyo.Inferior Adl1esif Auto-Scellant A CE,ndos Ap,pul.Inf6rieur (2)Step Two—Prepare.the starter course:,.For this step,take a 12"x 12"(305riun x 305mm)ridge cap piece and curt along the line between exposure aiid headlap(see Figure.2): 1 Figure 2 1 Exposure 203 hin-im Nall 3":(229 mm)from bottom Starter Course &-1"(2 5.mm)from edge e Bottom Backer Self-Sea!Adhesive on Back I�tOA No.: 13-4306.08 MIAM4DADECOUNTY 11 "'+ ►■I Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 7of9 (3)Step Three—Place the 4"x 12"(102mm 9 305mm)starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note: For cold weather application or for high wind zones see soecialapplication section below. (4)Step Four—Begin.laying full ridge-cap shingle pieces 12"x I!"(305mrn 005MM)as shown(see Figure 2). Apply with an.8"exposure beginning at the bottom of the hip or from the end of the ridge opposite,the direction of the prevailing wind, (5).Step Five—Apply ridge cap using 2 nails per piece 9"back frorn'thd exposed end and 1"up from the edge(see.Figure 3 for location of'nails).Use only zinc coated steel,oualuminum, 10-12 gauge,barbed, deformed or smooth shank roofing nails With heads 3/8"(9.5nun)to 7/10"(12mrn)in diameter. Nails should be tong enough to penetrate at least 3/4"(19tiun)into wood decks oriu-st through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle; Raised nails will interfere with the wind resistance of the shingles. Figure 3 10"(305nim) -F Top LaminaWPiece- 4c Piaza Superior Larninadt. 10M Pike Laminde 6 p6rieure .Nail FoVJ Lke Nail Clava Linea d-,Plinue Clavas clou Liqn1e�Pliage .0ou 203mm Special Application Section: For Cold Weather Application • In cold weather,warm OAF Timbertee Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather.;apply quarter-sized dabs of asphalt plastic cement(must conform to ASTM D4586 Type I or Type 11)!between ridge cap pieces and press firmly to insure good contact between pieces. • Note:Excessive application of tab adhesive can cause blistering of ridge cap shingle. WMIAMMADECOUtM NOA No.: 13-03,06.0.8 Expiration Date: 10/17/17 Approval Date: 08/15/13 Page.8 of 9 For High-Wind.Zones + In high wind'areas or for maximum wind resistance,apply-a.%"wide bead of Henkel.PL11 Urethane Sealant or Sonneborng NP-1T11 Urethane Sealant to each ridge cap shingle 1147-l"from the'shingle edge,parallel;to thejidge(see Figure 4). _ Figure-4 12' (305nim) T a`+'-�• Top I:amin6ted Pierce. 41 Pieza Superior Laniha& 102 Piaci Larnin&e Sup frieure idttiE 1 Fol,J Line. grail CiaVO 1 Unea cb,Pheque Claw Cion, Ligne Ik Pliage Ciaa �r 203mn7 j END OF THIS ACCEPTANCE MuartEaAaeco�t+rrtr NOA No.: 13-0306.08 ILII _� Expiration.Date: 10/11/17 Approval Date: 08/15%13 Page 9 of 9'