HomeMy WebLinkAboutEngineering ,t. COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com October 20, 2015 St. Lucie County Building Department 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Door specification prepared for the St. Lucie County Building Dept. for the structure located at 7300 Oleander Ave. St. Lucie County, Florida Manufacturer: Daybar Industries Limited Profiles: DBL 4080 Outswing Commercial Steel Door with panic exit, FL#.14941-R2 Wind Speed: 170 MPH; Ultimate Design Wind Speeds Code: Florida Building Code 2014; Exposure: B Risk Category: III Required Design Pressure: -52.7 Design Pressure: -70 Fasteners: 3/8"X5" flat head machine screw with expansion shields, 12"max @ Sill, 21"max @ Jambs, & 6"from each corner The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,.and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789