Loading...
HomeMy WebLinkAboutEngineering Company: The Home Depot At Home Services -Job Description: Replacing 18 windows sized Prepared By: Amber . Client Name: Carroll Project Number: 8668524 Vers o�to.o:; n: 4W I ND 'WALL onforms with ASCE 7 10- _. . DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 12 Risk Category 2 Building Width(ft) 50 Exposure Category D Building Length(ft) 24 Directionality Factor 0.85 Roof Slope (x:12) 3 Internal Pressure Coefficient+/ 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 9700-SHBI 5 5 36 50 40.0 -53.2 2 9700-SHBI 5 5 36 50 40.0 -53.2 3 9700-SHBI 5 5 34 37 40.6 -54.4 4 9700-SHBI 5 5 34 65 39.5 -52.1 5 9700-SHBI 5 5 34 65 39.5 -52.1 6 9700-SHBI 5 5 34 65 39.5 -52.1 7 9700-SHBI 5 5 36 50 40.0 -53.2 8 9700-SHBI 5 5 36 50 40.0 -53.2 9 9700-SHBI 5 5 35 25 40.6 -54.4 10 9700-SHBI 5 5 36 38 40.6 -54.4 11 9700-SHBI 5 5 36 38 40.6 -54.4 12 9700-SHBI 5 5 36 38 40.6 -54.4 13 9700-SHBI 5 5 36 38 40.6 -54.4 14 9700-SHBI 5 5 36 38 40.6 -54.4 15 9700-SHBI 5 5 36 38 40.6 -54.4 16 9700-SHBI 5 5 36 38 40.6 -54.4 17 9700-SHBI 5 5 36. 38 40.6 -54.4 18 9700-SHBI 5 5 36 38 40.6 -54.4 Width of End Zone(a)in feet= 3 5 h 51 Q - Y i �Q 5 5 Y STRUCTURES INTERNATIONAL,LLC 10/20/2015 9:14 AM MEN 10 11 William Carroll,48668524 7806 Pacific Ave. 1.2 Fort Pierce, FL 34951 Replacing 18 windows size for size with impact. 13 MEN 14 �2 1� 18 17 16 15 ., i.........................._.....,_. ._...._.._...._.............._.............. ..........._...... ............_....___._....................__..._..__...._........................_...............................................--i................... 1 Single Hung Window 36.E'x 50..." Entry FL 1435.4 *+ ;40.0, 53.2 2 Single Hung Window 36"x 50" Entry FL 1435.4 + ;40.0,f-1 53.2 3 Single Hung Window 34"x 37" Garage FL 1435.4 + '40.6, - 54.4 4 Single Hung Window 34"x 65" Den FL 1435.4 f 39.5, - 52.1 5 Single Hung Window 34"x 65" Den FL 1435.4 + :39.5, - 52.1 . 1 6 Single Hung Window 34"x 65" Den FL 1435.4 i- ;39.5, - 52.1 7 Single Hung Window 36"x 50" Kitchen FL 1435.4 + ;40:0, - 53.2 8 Single Hung Window 36"x 50" Kitchen FL 1435.4 + 40.0, -? 53.2 9 Single Hung Window 35"x 25" Bathroom FL 1435.4 + .40.6,;- 54.4 j 10 Single Hung Window 36"x 38" Bedroom FL 1435.4 + A0.6, -! 54.4 11 Single Hung Window 36"x 38" Bedroom FL 1435.4 + '40.6, - .54.4 12 Single Hung Window 36"x 38" Bedroom FL 1435.4 + ;40.6, - 54.4 113 Single Hung Window 36"x 38" Bedroom FL 1435.4 + .40.6,1-1 54.4 14 Single Hung Window 36"x 38" Bedroom FL 1435.4 + :40.6, - 54.4 15 Single Hung.Window 36"x 38" Bedroom FL 1435.4 + ;40.6,;-' 54.4 16 Single Hung Window 36"x 38" Bedroom FL 1435.4 + 40.6, - 54.4 17 Single Hung Window 36"x 38" Bedroom FL 1435.4 -1- ;40.6,(- 54.4 E 18 Single Hung Window 36"x 38" Bedroom FL 1435.4 + ;40.6, -j 54.4 `Line items 1 and 2 are being mulled together. Line items 4,,5, and 6 =are being mulled together. Line items 7 and 8 are being mulled (together. Line items 10 and 11 are being mulled together. Line items 15 and 16 are being mulled together. Line items 17 and 18 are being Oulled together.All are using NOA 14-1105.01.