Loading...
HomeMy WebLinkAboutProduct Approval MIAMI. C1E MIAMI-DADE COUNTY , - t PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD.COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street,Room'208 BOARD AND-CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)31-5-2599 NOTICE OF ACCEPTANCE (NOA} ww�v:intamidaiie.aovrbaGldinel Iko Industries Ltd: 40 Hansen Rd.S. Brampton,Ontario CANADA. UWH4 SCOPE: This NO is being'issued under the applicable rules and regulations governing the use of construction materials. The'documentation submitted has been reviewed and accepted by Miami-Dade County BNC=Product Control Section to be.used in-Miami Dade County and other areas where allowed by the Authority Having Jurisdiction- This NOA shall-not be valid after the expiration date stated below:The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade.County)reserve the right to-have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner;the manufacturer will incur the expense of such testing and the AHJ may- immediately revoke, modify,.or suspend the-use-of such product or material within their.jurisdiction: BNC reserves the.:right to revoke this acceptance, if itis determined by Miami-Dade County Product-Control Section that this product or material fails to meet the requirements of the applicable building code. This-product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Cole. DESCRIPTION: AR LABELING: Each.unit shall bear h:permanent label with the manufacturer's name or logo,-ci%state.and- .- following statement:-"Miami-Dade County Product Control Approved",unless otherwise noted herein: RENEWAL;of this NOA shall be considered after a renewal application.has been filed and there,has-been no" change.in-the:applicable building code negatively affecting the performance of this;product. TERMINATION of this NOA will occur after the expiration date or-if there has been.a revision or change in the materials;use;and/or manufacture of the product or process.Misuse.of this NOA as an endorsement of any. product,for sales,advertising or any-other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and remval,of NOA. ADVERTISEMENT: The NOA number preceded by the words"Miami-Dade:County,.Florida, and followed:by- the expiration date may be.displayed-in advertising literature. If any portion of the NOA is displayed,then it shall be done in,its entirety: INSPECTION:A copy of this entire NOA shall be,provided to the user by.the manufaeturer or its distributors and shall be available for.inspection at the job site at the request of the Building Official. This revises NOA# 10-09.13.02 and consists of pages 1 through 4. The submitted-documentation'was reviewed by Alex Tigera. NOA.No.: 11-0517.09..: Expiration Date:. 05%05/16 "MMM7AD,cOU Approval Dater07/07/11- Page I-of 4,. ROOFING ASSEMBLY APPROVAL Cate or Roofing Sub-Category: Asphalt Shingles Materials. Laminate Deck Tyae:. Wood SCOPE . This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance. PRODUCTDESCRIPTION Product Dimensions Test Product Descriation Specifications Cambridge AR : l3 3/4"x:40'/e TAS no - A-heavyweight,fiberglass reinforced laminate asphalt shingle. MANUFACTURING.LOCATION 1.-. Kankakee;IL -EVIDENCE-SUBMITTED Test Agency Test Identifier Test.Name/Renort Date PRI-Construction Materials-Inc.. IKO-050-02-01 . TAS.100. - 12/21/69 FM Approvals 3041689 ASTM D 3462-- 02/23/11 FM Approvals, _ 3036971- ASTM.D 31.61:-(TAS-107). : 01/04/09: FM Approvals. , 3042673 ASTM E 108 04/12/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. -Shall.not be installed on roof mean heights.in excess of 33 ft. 3. All products listed herein shall have a quality, assurance audit in accordance with the,Florida Building Code and Rule 9B-72 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard.RAS 115. 2'. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W,attached. 5. Nailing shall be in compliance with Detail-W,attached. NOA No.: 11-0517.09. MIAM4bAbE COUNTY Expiration Date:. 05/05/16 • Approval Date:07/07/11 . . . . . . . Page 2.of 4- LABELING. 1. Shingles.shall,be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". CMIAMIMLAMICADE,COUNTY BUILDING PERMIT.REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1:1 This Notice of Acceptance. 1.2 Any.other documents.required by the Building Official or the.applicable code in order to properly -evaluate the installation of this system. . NOA No. :.11-0517.09 MIMMI. ►DE COUNTY Expiration Date: 05/05/16 .•••U81 Approval Date:.07/07/11 Page 3:of 4. DETAIL A CAMBRIDGE AR COURSE LAYOUT DGE OF ROOF -------------- -------- Note:.Roofing Cement not shown to this layout This drawing is for oourse layout only. See Wall B I- ----=-----=-- for nailing and cement placemant details THIRD COURSE - - - 1 t ------ ------ SECOND COURSE IN - 1 I I . . . . . . J 1 40 FIRST COURSEME ff m m DETAIL B CAMBRIDGE AR 40 B„ i 1i, 13 all 6 all 5=" EXPOSURE END OF THIS ACCEPTANCE. NOA No.:11-0517.09. MIAMI-DADE COUNTY Expiration Date: 05/05/16 Approval Date- 07/07/11 . .. .Page 4 of 4