Loading...
HomeMy WebLinkAboutEngineering A FILE COPY ENGINEERING & TESTING, INC. FILLO Phone: (866)781-6889•Fax: (866) 781-8550 R E C E I'.' D NOV 0 4 mfloridaenoineeringandtesting.com 250 S.W.13`�'Av enue Pompano Beach,FL 33069 DATE: 11/03/15 JOB ORDER#: 15-3341 CLIENT: All Area Roofing ADDRESS: 3921 S.US Highway 1 Fort Pierce,Florida 34982 PROJECT: Farrington Residence Flat Wood Roof Deck ADDRESS: 190 S.E. Celestia Court Port Saint Lucie,FL 34983 FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Height= 9' Exposure: C Basic/Ultimate Wind Speed: Vilt=170 mph Length= 5 P Category: II Nominal Wind Speed: Vasd=Vu1t*0.6 Width= 37' Slope: <7° (asd=allowable strength design) Parapet Wall: <3' Residential K7=0.85, Kzt= 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q=0.00256*KXK tKdV2 Velocity Pressure (ult): q=0.00256(0.85)(1.0)(0.85)(170)2] =53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*y6.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(37') = 3.7' 0.4(9') = 3.6' } use: 4'0" Effective Wind Area: <10ft2 For parapet height three feet(3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 I,i� `SMI 1t Q W Qrcatity�j A�ill assurance Page Z, 11/03/15,Job Order#15-3341 All Area Roofing " Farrington Residence-FIat Wood Roof Deck F11,01VIPA 190 S.E.Celestia Court;Port Saint Lucie,FL 34983: Design Pressures Based on Vasd: 1) Field PI = 32.07*[(-l.0)–(0.18)1 =-37.8 psf 2) Perimeter P2 = 32.07*[(-1.8)–(0.18)1 =-63.5 psf 3) Corners P3 = 32.07*[(-2.8)–(0.18)1 =-95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #14-0224.03, System Type E(1),pg 12 of 16,with a maximum design pressure of -52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non-insulated) deck utilizing approved I 1 ga. annular ring shank nails and approved tin caps: Field: 8" o.c. a)4" laps and 3 staggered rows 8" o.c. Perimeter: 8" o.c. @a 4" laps and 4 staggered rows 8" o.c. Corners: 6" o.c. @u 4" laps and 5 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a=4'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sm`cezely - e- . a % , = .Mark,A::Mesiarid=-P.E. Florida Engineering'8i Testing, Inc. l Florid'a`Reg. No48202 Certificate of Authorization No. 6923