HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com November4, 2015 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 3012 Eagles Nest Way,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply& Manufacturing Profiles: 26 GA GulfLok Roof Panel FL. #11651.16 Code: FBC 2014;Section R 905.10 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 2/12 Required Design Pressure: Zone1:-40.6 Zone 2: -56.5 Zone3:-107.9 Maximum Uplift Pressure: Fastener spacing: -121.75 psf @ 5-3/16" o.c. Fasteners: #10-12 x 1" Pancake type A w/Sealing with%" minimum penetration spaced @ 5-3/16"o.c. zone 1,2,3 Underlayment: Soprema, Inc. FL#2569.1 Resisto is a self-adhering,glass-mat reinforced, sand-surfaced, sbs modified bitumen Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c.thru out Zone 1,4" o.c. perimeter& 6"o.c.field Zone 2, and 4" o.c.thru out Zone3 The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789