Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Load Calculation
RE C E I!17-® iw i 09-2015 Company: The Home Depot At Home Services Job Description:- Replacing 15 windows size Prepared By: Amber Client Name: Galiano Project Number: 8714355 =Verson 10 0". -c 2012 5tructuSeslntern is al C � x °._,� °„-a <-' . DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 15 Risk Category 2 Building Width(ft) 80 Exposure Category D Building Length(ft) 55 Directionality Factor 0.85 Roof Slope (x:12) 3 Internal Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 9700-PW BI 5 5 39 73 38.8 -50.8 2 9700-PW BI 5 5 22 73 40.1 -53.3 3 9700-PW BI 5 5 46 73 38.4 -49.9 4 9700-PW BI 5 5 22 73 40.1 -53.3 5 9700-PW BI 5 5 39 73 38.8 -50.8 6 9700-SH BI 5 5 24 47 40.6 -54.4 7 9700-SH BI 5 5 47 58 38.9 -51.0 8 9700-SH BI 5 5 47 58 38.9 -51.0 9 9700-SH BI 5 5 47 58 38.9 -51.0 10 9700-SH BI 5 5 24 34 40.6 -54.4 11 9700-SH BI 5 5 36 60 39.6 -52.3 12 9700-SH BI 5 5 36 60 39.6 -52.3 13 9700-SH BI 5 5 47 34 40.4 -53.9 &15 mulh 2 PW BI 4 3 88 77 36.5 -40.0. Width of End Zone(a)in feet= 5.5 5 h si 0 O a Y i s s STRUCTURES INTERNATIONAL,LLC »- 11/3/2015 2:04 PM Vincent and Kimberly Galiano,#8714355 5803 S.Indian River Dr. 12 -----I Port Pierce, PL 34954 Replacing 15 windows size for size with impact:_ 11 The cosi:of the job is 6.5%of the E structures' assessed.value. 10 E= FEEME1 71 i • i i 13 i 14&15 1 Picture Window 39"x 73" Living Room FL 5012.8 -! 2 Picture Window 22"x 73" Living Room FL 5012.8 -T- 401, —;.53.3 3 Picture Window 46"x 73" Living Room FL 501.2.8 f 38.4,1-1 49.9 4 Picture Window 22"x 73"' Living Room FL 5012.8 + 40.1,:-153.3 5 Picture Window 39"x 73" Living Room FL 5012.8 ;38.8, —;50.8 6 Single Hung Window 24"x 47" Hall FL 1435.4 + :40.6,.-154.4 7 Single Hung Window 47"x 58" Bedroom FL 1435.4 + :38.9:,:-151.0 8 Single Hung Window 47"x 58" Bedroom FL 1435.4 + 38.9, — 51.0 9 Single Hung Window 47"x 58" Bedroom FL 1435.4 + 38.9,.;— 51.o 10 Single Hung Window 24"x 34" Bathroom FL 1435.4 + 40.6, — 54.4 11 Single Hung Window 36"x 60" Bedroom FL 1435.4 139.6L,`— .52.3 12 Single Hung Window 36"x 60" Bedroom FL 1435.4 T '39.6,:-152.3 13 Single Hung Window. 47"x 34" Kitchen FL 1435.4 1413.4, —153.9 14 Picture Window 88 x 25" Kitchen FL 5012.8 ;36.5, - 40.0 15 Picture Window 88"x 52" Kitchen FL 5012.8 ;36.5,1-140.0 Line items 2, 3, and 4 are being mulled together.Line items 14 and 15 rare being mulled together.All are using iVOA 14-1105.01.