Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 6 � pp Flo�da @ "r1°rt? BCIS Home i Log In I User Registration i Hot Topics I Submit Surcharge ! Stats&Facts Publications FBC Staff Busines of ,product Approval Professi gal USER: Public User Regulation Product Approval Menu > Product or Application Search > Application List>Application Detail FL# FL5012-R15 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall POC and/or the Commission if necessary. Comments Archived Product Manufacturer PGT.Industries Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941) 486-0100 Ext 22318 druark@pgtindustries.com Authorized Signature Jens Rosowski j rosowski@pgtind ustri es.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941) 486-0100, Ext 21140 jrosowskiC@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Steven M, Urich, PE wj Validation Checklist- Hardcopy Received Referenced Standard and Year (of Standard) Standard AAMA 506 AAMA/WDMA/CSA 101/IS2/A440 AAMA/WDMA/CSA 101/IS2/A440 AAMA/WDMA/CSA 101/IS2/A440 ASTM E1886 ASTM E1996 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE... 7/17/2015 Florida Building Code Online Page 2 of 6 ASTM E283 ASTM E330 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/11/2015 Date Validated 06/19/2015 Date Pending FBC Approval Date Approved 06/27/2015 Summary of Products FL# Model, Number or Name Description 5012.1 FCA- 440 Vinyl Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC 190-795CAR Approved for use outside HVHZ: Yes FL5012 R15 C CAC 190-796CAR Impact Resistant: No Quality Assurance Contract Exp Design Pressure: N/A 10/28/2015 Other: Please see the Installation Instructions for design Installation Instructions pressure, size and anchorage information. FL5012 R15 11 FCA-440.pdf Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-440 Evaluat Created by Independent Third Par, 5012.2 FCA- 540 WinGuard Vinyl Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC 190-2701CAI Approved for use outside HVHZ: Yes FL5012 R15 C CAC 190-795CAR Impact Resistant: Yes FL5012 R15 C CAC 190-796CAR Design Pressure: N/A Quality Assurance Contract Exp Other: Please seethe Installation Instructions for design 10/28/2015. pressure, size and anchorage information. Installation Instructions FL5012 R15 II FCA-540.pdf Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-540 Evaluat 'Created by Independent Third Par 5012.3 FCA - 640 Aluminum Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC CAPW-640 C Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 02/25/2019 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-640.12df pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par- Evaluation arEvaluation Reports FL5012 R15 AE FCA-640 Evaluat Created by Independent Third Par https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE... 7/17/2015 Florida Building Code Online Page 3 of 6 5012.4 FCA-5440 EnergyVue Vinyl Fixed Casement\A Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC PW-5440 Ce Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 07/29/2018 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-5440 pd pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 5E Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-5440 EvaluE Created by Independent Third Par 5012.5 FCA-5540 WinGuard Vinyl Fixed Casement Wi Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC PW-5540 Ce Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: Yes 08/12/2018 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-5540.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 5E Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-5540 Evaluz Created by Independent Third Par 5012.6 PW - 220 Aluminum Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC F-220 Certifi .Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 10%24/2017 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 F-220.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports 'FL5012_R15_AE_F-220 Evaluatior Created by Independent Third Par 5012.7 PW- 420 Vinyl Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC F-420 Certifi Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 08%01/2017 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 F-420.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE F-420 Evaluatior Created by Independent Third Par 5012.8 PW- 520 WinGuard Vinyl Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C-CAC Certification! ; a^ sr �tce HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: Yes 08/15/2016 Desig u e. Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 F-520.12df pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE F-520 Evaluatior Created by Independent Third Par https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGE... 7/17/2015 i GENERAL NOTES: IMPACT-RESISTANT I 1)THE ANCHORAGE METHODS SHOWN ANCHOR LOCATIONS HAVE BEEN DESIGNED TO COMPLY WITH &SPACING THE FLORIDA BUILDING CODE FOR THE DESIGN PRESSURES LISTED. 2)WOOD BUCKS DEPICTED AS 1X ARE MAX.BUCK g"MAX. MAX.BUCK MAX LESS THAN 1-1/2'THICK.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE.WOOD I BUCKS DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.ATTACHMENT METHOD OF ' WOOD BUCKS SHALL BE DONE BY OTHERS. 4' 3)SEE TABLES FOR MINIMUM EDGE MAX. DISUBSTRATE EDGE(EXCLUDING FINISH OR STANCE FROM CENTER OF ANCHOR TO MAX. � � MAX � �O.C. BUCK i STUCCO). BUCK 4)SHIM EACH ANCHOR LOCATION WHERE 12--"MAX.O.C. � THE PRODUCT IS NOT FLUSH TO THE } SUBSTRATE,USING SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 5)ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE FOR SUBSTRATE MATERIAL.DISSIMILAR MATERIALS SHALL BE PROTECTED AS g" MAX "MAX.O.C. 2"MAX.—^•� �•�— —�•I ►—4"MAX.O.C. REQUIRED TO PREVENT REACTIONS. 1 ALUMINUM SHALL BE PROTECTED FROM DISSIMILAR MATERIALS AS SPECIFIED IN FLANGE FRAME INTEGRAL FIN FRAME THE FLORIDA BUILDING CODE. 6)ADHESIVE SEALANT SHALL BE USED TABLE 2:ANCHORS FOR FLANGE WINDOWS TABLE 3:ANCHORS FOR FIN WINDOWS i. BETWEEN SUBSTRATE AND FLANGE OR FIN. OVERALL SEALINGIFLASHING Min.Edge Min. Min.Edge Min. STRATEGY FOR WATER RESISTANCE OF Anchor Substrate Distance Embedment Anchor Substrate Distance Embedment f INSTALLATION SHALL BE DONE BY OTHERS. P.T.Southern Pine(SG-.55) 112" 1.3/8' 2-112"x.113'Box Nail P.T.Southern Pine(SG=.55) 5/16" 2-7/16' I 1710 Sheet Metal Screw, Aluminum,0063-75 min. 318' 1/8" 2-1/2"x-131'Common Neil P.T.Southern Pine(SG-.55) 3/8" 2-7/16' 7)MATERIALS USED FOR ANCHOR G5 Steel or 410 Steel Stud,Gr.33 min. - 318" 0.0346"(20 ga) 2-1/2"x.145"Roofing Nall P.T.Southern Pine(SG=.55) 3/8" 2-7116' EVALUATIONS WERE SOUTHERN PINE,2.7 Stainless Steel KSI CONCRETE AND CONCRETE MASONRY A36 Steel 318' 1/8" P.T.Southern Pine(SG-.55) 1!2" 1-318" UNITS COMPLYING WITH ASTM C-90. P.T.Southern Pine(SG=.55) 112" 1.3/8' Aluminum,606&Tb min. 3/6" 1/8" GLAZING COMPLIES WITH ASTM E1300. 3116"Steel UOracon Concrete(min.2.7 ksl) 1" 1" 010 Steel SMS Steel Stud,.Gr.33 min. 3/8" 0.0346"(20 ga) 8)THE 1/3 STRESS INCREASE WAS NOT Ungmuted CMU,(ASTM C-90) 1" 1-1l4' A36 Slee) 318" USED IN THIS ANCHOR EVALUATION.THE NOTE:FOR ALL METAL SUBSTRATES,SCREW EMBEDMENT SHALL BE MIN.3 THREADS BEYOND INSIDE FACE OF NOTE:FOR ALL METAL SUBSTRATES,SCREW EMBEDMENT SHALL BE MIN.3 THREADS BEYOND INSIDE FACE OF MATERIAL. 1.6 LOAD DURATION FACTOR WAS USED MATERIAL i FOR THE EVALUATION OF WOOD SCREWS. i 9)IF THE EXACT PRODUCT SIZE ISNOT SHAPES MAYBE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING LISTED IN THE TABLES,ALWAYS ROUND DESIGN PRESSURES FOR THAT BLOCK SIZE FROM THE TABLE ON THIS SHEET. UP TO THE NEXT LARGER VALUE. I ,1',t Hurl; TABLE I:AS TESTED ,(•411 r:, �9i(, u..n er o,r.• rHIFFNEoMw a'S007111nLUNAW Window Buck Size tleslgn Preeeure Certification ".? J.ROSOWSKI 07110111 VINYL •wmr ♦ Numbers �' ;{ Re,4trr ANDPROPRIETARKNOPORTIONOPTIAS DCCAEhrwreEUS0ORR7F?=L f1 !48' 6' 60' 80 t30 180227,474 l r:o,;;T uS Aw�wannmm�emxeamwme _ ARILMONKWPOM UM 5 230,475 /^r� r •' _ _ ® �� 5' 60' 60 80 190-228 -�. 6 �O �7 I=!- 1070 TECHNOLOGY ORNE 62' 75 75 180.232,701 T •`�Q-^ NOKOMIS,FL 34275 FLCERT.OF AUTH.:29296 PICTURE WINDOW . •�..: Sefr71�! Snb: &at LYMpNa � rLr. ""••, 'p A.Lynn Miller,P.E. f '�r`�i')i^'•�.,,� P.E.p58705 PW-520 NTS 1 of 3 3071011JR i I INSTALLATION WITH FLANGE FRAME i EDGE DISTANCE- S BST T EDGE DISTANCE—I--•I EMBEDMENT SUBSTRATE o SUBSTRATE `Lf' EX EXTERIOR EMBEDMENT / { 1X WOOD \ O 3-1l4" SHIM SHIM - o Op o r� �� E SHIM EXf EXTERIOR EXTERIOR FLANGE FRAME, C(DIR�E­CTLY AMB INSTALLATION FLANGE FRAME, FLANGE FRAME, SUBSTRATE) HEAD INSTALLATION HEAD INSTALLATION { (USING 1X BUCKSTRIP) (DIRECTLY TO SUBSTRATE) SUBSTRATE EXTERIOR i ti r; a EXTERIOR EXTERIOR I Oo SHIM 1X WOOD SHIM SHIM FLANGE FRAME, ZZ/ 1X WOOD JAMB INSTALLATION (USING 1X BUCKSTRIP) X SUBSTRATE NGE FRAME, SILLINSTALLATION SUBSTRA (DIRECTLY TO SUBSTRATE) LOz'R•''' FLANGE FRAME, `^i•itS�- SILL INSTALLATION . e% Dale: MaW1eC DE WDiWDdIDEttlN0161UDWfaAID (USING 1X BUCKSTRIP) J.ROSOWSKI 07/10/11 VINYL �.,W,W�VfPWWV I NovBE LLM IlaNtlam: oo*N wusrwr.'roa luRo DCTws aDaxroirwreeDsroaenEmDuaDa .wrwrerwrrMartn�mwcss®wrrma � - vew¢snva�remtarwEs INSTALLATION NOTES: 1)SEE SHEET 1 FOR SPACING REQUIREMENTS. 10767ECHNOLocroRNE I. 2)SEE TABLE(S)ON SHEET 1 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. NOKOMIS.FL 34275 T1°" 3)MAX.SHIM THICKNESS TO BE 114-. FL CERT.OFAUTH.:29296 PICTUREWINDOW 4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS. sarmvm t son — 5)FLANGE MAY BE REMOVED FOR EQUAL-LEG FRAME APPLICATIONS.USE FLANGE INSTRUCTIONS. A.Lynn End 'E PW-520 NTS 2 of 3 3071011JR { INSTALLATION WITH FIN FRAME 7/16"LAMI _-1„ GLASS NOMINAL-^1 3/16"ANNEALED OR EMBEDMENT �- .090"DUPONT -HEAT STRENGTHENED SGPINTERLAYER - GLASS EDGE SUBSTRATE AIRSPACE DISTANCE I I 3/16"ANNEALED OR HEAT STRENGTHENED 3/16"ANNEALED GLASS GLASS IZA EDGE J SHIM DISTANCE 1/2" EXTERIOR NOM. ;O EXTERIOR DOW 1199_ I "1 SILICONE EXTERIOR D FIN FRAME, I HEAD INSTALLATION GLAZING OPTIONS 00 i i 1" 5/16"LAMI SHIM GLASS NOMINAL 1/8"ANNEALED t FIN FRAME, 090"DUPONT GLASS I JAMB INSTALLATION SUBSTRATE PVBINTERLAYER a ^ - AIRSPACE [�> 1/8"ANNEALED 3/16"ANNEALED 7��! � —j GLASS _ EXTERIOR GLASS SHIM � M NO . fl EXTERIOR I U f DOW 1199 SUBSTRATE SILICONE FIN FRAME, 1 SILL INSTALLATION I , . '=..•(Y\..il.l ".[:��, om�er- ux": wmme naeor�awncw.oeccnEOMTACW M I '',' iman�EEmusrrerrm�nrrcwEcr S J.ROSOWSKI 07110111 VINYL #=n?MANDCOh CONFDffM. t INSTALLATION NOTES: ' .'`-"�^••' aero. u+oiwaaxieruarr+nxnnarocnns OppAfFNlMA1BE USED gIflF.TdJIX,YtDIX . - _ MNRYtlA WFGrmsmm rDFEARE55ED t4RlRBE 1)SEE SHEET 1 FOR SPACING REQUIREMENTS. 2)SEE TABLE(S)ON SHEET 1 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. 3 MAX.SHIM THICKNESS TO BE 114". — t- 7070 TECHNOLOGY DRIVE4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN C �m S: l r; NOKOMIS,FL 34275 m REQUIREMENTS. wuE 01- . FL CERT.OF AUTH.:29295 PICTURE WINDOW 5)FIN AND FLANGE MAY BE REMOVED FOR EQUAL-LEG FRAME APPLICATIONS,USE FLANGE r .�•p4�.•'('� '•-� :ti A.Lynn Miller,P.E. s'ssvodo INSTRUCTIONS ON SHEET S'jr�;.,!t;y�" P.E.1156705 PW-520 NTS 3 of 3 3071D11JR